Literature DB >> 17318664

Effect of 308-nm excimer laser light on peri-implantitis-associated bacteria: an in vitro investigation.

Herbert Deppe1, Hans-Henning Horch, Veit Schrödl, Cornelia Haczek, Thomas Miethke.   

Abstract

Dental implants are becoming increasingly important in prosthodontic rehabilitation. Bacterial infections, however, can induce bone loss and jeopardize clinical success. Recent literature has demonstrated that infrared CO(2) laser light is suitable for the decontamination of exposed implant surfaces. The aim of the present study was to investigate the influence of 308-nm excimer laser irradiation on peri-implantitis-associated bacteria in vitro. In this study, a XeCl excimer laser (308 nm) was used (Summit Technology, Boston, USA). Both aerobe (Streptococcus mutans, S. sanguis, Actinomyces naeslundii) and anaerobe microorganisms (A. odontolyticus, Prevotella melaninogenica) were tested. According to previous studies, a constant energy of 0.8 J/cm(2) and a constant frequency of 20 Hz were used for all irradiations. Colony-forming units after laser irradiation were counted. Excimer laser irradiation showed significant influence on the growth of all microorganisms. As compared to S. mutans and S. sanguis, A. naeslundii demonstrated higher sensitivity to laser irradiation. Anaerobe microorganisms, in contrast, demonstrated that a total of 200 pulses were sufficient to reduce the replication of these germs for more than 99.9%. Excimer laser irradiation (lambda = 308 nm) can significantly reduce both aerobe and anaerobe microorganisms. Depending on the parameters chosen, 200 pulses are sufficient for sterilization. New studies are necessary to evaluate if this wavelength is more of value in the treatment of peri-implantitis than other wavelengths or conventional therapies.

Entities:  

Mesh:

Year:  2007        PMID: 17318664     DOI: 10.1007/s10103-007-0441-2

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  13 in total

1.  Bactericidal action of 308 nm excimer-laser radiation: an in vitro investigation.

Authors:  M Folwaczny; T Liesenhoff; N Lehn; H H Horch
Journal:  J Endod       Date:  1998-12       Impact factor: 4.171

2.  Bone tissue ablation with sub-microS pulses of a Q-switch CO(2) laser: histological examination of thermal side effects.

Authors:  M M Ivanenko; S Fahimi-Weber; T Mitra; W Wierich; P Hering
Journal:  Lasers Med Sci       Date:  2002       Impact factor: 3.161

3.  Comparative bactericidal exposures for selected oral bacteria using carbon dioxide laser radiation.

Authors:  D N Dederich; M A Pickard; A S Vaughn; J Tulip; K L Zakariasen
Journal:  Lasers Surg Med       Date:  1990       Impact factor: 4.025

4.  Peri-implant care of ailing implants with the carbon dioxide laser.

Authors:  H Deppe; H H Horch; J Henke; K Donath
Journal:  Int J Oral Maxillofac Implants       Date:  2001 Sep-Oct       Impact factor: 2.804

5.  Sterilization potential of the CO2 laser.

Authors:  S Nammour; P Majerus
Journal:  Acta Stomatol Belg       Date:  1991-12

6.  CO2 lasers and temperature changes of titanium implants.

Authors:  D K Oyster; W B Parker; M E Gher
Journal:  J Periodontol       Date:  1995-12       Impact factor: 6.993

7.  Surface properties of endosseous dental implants after NdYAG and CO2 laser treatment at various energies.

Authors:  Cheung-Yeoul Park; Su-Gwan Kim; Myung-Duck Kim; Tae-Gwan Eom; Jung-Hoon Yoon; Sang-Gun Ahn
Journal:  J Oral Maxillofac Surg       Date:  2005-10       Impact factor: 1.895

8.  Sensitization of periodontopathogenic bacteria to killing by light from a low-power laser.

Authors:  M Wilson; J Dobson; S Sarkar
Journal:  Oral Microbiol Immunol       Date:  1993-06

9.  Lethal photosensitization of bacteria in subgingival plaque from patients with chronic periodontitis.

Authors:  S Sarkar; M Wilson
Journal:  J Periodontal Res       Date:  1993-05       Impact factor: 4.419

10.  Conventional versus CO2 laser-assisted treatment of peri-implant defects with the concomitant use of pure-phase beta-tricalcium phosphate: a 5-year clinical report.

Authors:  Herbert Deppe; Hans-Henning Horch; Andreas Neff
Journal:  Int J Oral Maxillofac Implants       Date:  2007 Jan-Feb       Impact factor: 2.804

View more
  6 in total

1.  Antibacterial property expressed by a novel calcium phosphate glass.

Authors:  Lela Liu; Smruti Pushalkar; Deepak Saxena; Racquel Z LeGeros; Yu Zhang
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-09-11       Impact factor: 3.368

2.  Quantitative evaluation of bacteria adherent and in biofilm on single-wall carbon nanotube-coated surfaces.

Authors:  Fabrizio Pantanella; Francesca Berlutti; Daniele Passeri; Daniela Sordi; Alessandra Frioni; Tiziana Natalizi; Maria Letizia Terranova; Marco Rossi; Piera Valenti
Journal:  Interdiscip Perspect Infect Dis       Date:  2011-10-05

Review 3.  Definition, etiology, prevention and treatment of peri-implantitis--a review.

Authors:  Ralf Smeets; Anders Henningsen; Ole Jung; Max Heiland; Christian Hammächer; Jamal M Stein
Journal:  Head Face Med       Date:  2014-09-03       Impact factor: 2.151

4.  Patient-reported outcomes and complication rates after lateral maxillary sinus floor elevation: a prospective study.

Authors:  Carlo Rengo; Antonino Fiorino; Alessandro Cucchi; Antonio Nappo; Emanuele Randellini; Paolo Calamai; Marco Ferrari
Journal:  Clin Oral Investig       Date:  2021-02-23       Impact factor: 3.573

5.  Functionalization of titanium with chitosan via silanation: evaluation of biological and mechanical performances.

Authors:  Pauline Renoud; Bérangère Toury; Stéphane Benayoun; Ghania Attik; Brigitte Grosgogeat
Journal:  PLoS One       Date:  2012-07-31       Impact factor: 3.240

Review 6.  Treatment Alternatives to Negotiate Peri-Implantitis.

Authors:  Eli E Machtei
Journal:  Adv Med       Date:  2014-06-15
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.