Literature DB >> 17315767

A review of pre-clinical testing of femoral stem subsidence and comparison with clinical data.

S Gheduzzi1, A W Miles.   

Abstract

Immediate postoperative stability of femoral stems is one of the key factors for the long-term success of total hip replacement. The need to develop a reliable technique to assess in vitro implant stability under physiological loading conditions is widely recognized. A critical review of the in vitro techniques developed for the assessment of implant stability is presented. In vitro predictions of subsidence are compared to in vivo clinical data available from Roentgen stereophotogrammetric analysis (RSA) studies. Limited correlation between in vitro predictions of stability and clinical measurements of subsidence obtained through RSA data was found even though similar migration patterns could be distinguished.

Mesh:

Year:  2007        PMID: 17315767     DOI: 10.1243/09544119JEIM129

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  5 in total

1.  Using 'subcement' to simulate the long-term fatigue response of cemented femoral stems in a cadaver model: could a novel preclinical screening test have caught the Exeter matt problem?

Authors:  A Race; M A Miller; K A Mann
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

2.  Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study.

Authors:  David Campbell; Graham Mercer; Kjell G Nilsson; Vanessa Wells; John R Field; Stuart A Callary
Journal:  Int Orthop       Date:  2009-12-13       Impact factor: 3.075

3.  Acoustic pattern evaluation during cementless hip arthroplasty surgery may be a new method for predicting complications.

Authors:  Itaru Morohashi; Hideaki Iwase; Akio Kanda; Taichi Sato; Yasuhiro Homma; Atsuhiko Mogami; Osamu Obayashi; Kazuo Kaneko
Journal:  SICOT J       Date:  2017-02-13

4.  Comparisons of the surface micromotions of cementless femoral prosthesis in the horizontal and vertical levels: a network analysis of biomechanical studies.

Authors:  Bomin Wang; Qinghu Li; Jinlei Dong; Dongsheng Zhou; Fanxiao Liu
Journal:  J Orthop Surg Res       Date:  2020-07-31       Impact factor: 2.359

5.  Two Different Methods to Measure the Stability of Acetabular Implants: A Comparison Using Artificial Acetabular Models.

Authors:  Quentin Goossens; Leonard Cezar Pastrav; Michiel Mulier; Wim Desmet; Jos Vander Sloten; Kathleen Denis
Journal:  Sensors (Basel)       Date:  2020-01-01       Impact factor: 3.576