Literature DB >> 1731536

Response time of pulse oximeters assessed using acute decompression.

D Young1, C Jewkes, M Spittal, C Blogg, J Weissman, D Gradwell.   

Abstract

In human volunteers, the response times of 11 pulse oximeters to a 10% step reduction in arterial oxygen saturation were measured using an acute decompression technique. When finger probes were used, nine oximeters had similar response times and two were significantly slower (P less than 0.05). The ear probe response time was similar on six oximeters assessed, and faster than the finger probes. The response times of the oximeters to an acute increase in arterial saturation were tested by suddenly changing the inspired gas from air to 100% oxygen at an ambient pressure of 380 mm Hg. For ear probes, the response times were similar for all oximeters; for finger probes, three fast-responding and three slow-responding oximeters were identified (P less than 0.05). A faster response could be elicited by placing the probes on the thumb (P less than 0.05). We conclude that if a rapid indication of changes in arterial saturation is required, pulse oximeters with ear probes should be used. If finger probes are used, they should be placed on the thumb. The oximeter used will influence the response time if finger probes are used, but it will have little effect if ear probes are used.

Entities:  

Mesh:

Year:  1992        PMID: 1731536     DOI: 10.1213/00000539-199202000-00003

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  Measuring gas exchange with step changes in inspired oxygen: an analysis of the assumption of oxygen steady state in patients suffering from COPD.

Authors:  Lars P Thomsen; Ulla M Weinreich; Dan S Karbing; Peter D Wagner; Stephen E Rees
Journal:  J Clin Monit Comput       Date:  2014-10-02       Impact factor: 2.502

2.  Pulse Oximetry: The Working Principle, Signal Formation, and Applications.

Authors:  Timo Leppänen; Samu Kainulainen; Henri Korkalainen; Saara Sillanmäki; Antti Kulkas; Juha Töyräs; Sami Nikkonen
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 3.650

3.  Pulse oximetry.

Authors: 
Journal:  Crit Care       Date:  1999       Impact factor: 9.097

Review 4.  Pulse oximetry.

Authors:  Amal Jubran
Journal:  Crit Care       Date:  2015-07-16       Impact factor: 9.097

5.  Impact of COVID-19 on the association between pulse oximetry and arterial oxygenation in patients with acute respiratory distress syndrome.

Authors:  Lee S Nguyen; Marion Helias; Lisa Raia; Estelle Nicolas; Paul Jaubert; Sarah Benghanem; Zakaria Ait Hamou; Pierre Dupland; Julien Charpentier; Frédéric Pène; Alain Cariou; Jean-Paul Mira; Jean-Daniel Chiche; Mathieu Jozwiak
Journal:  Sci Rep       Date:  2022-01-27       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.