Literature DB >> 1731468

Evaluation of changes in standard electrocardiographic QRS waveforms recorded from activity-compatible proximal limb lead positions.

O Pahlm1, W K Haisty, L Edenbrandt, N B Wagner, D C Sevilla, R H Selvester, G S Wagner.   

Abstract

Proximal limb lead positions are currently used for activity-compatible electrocardiographic monitoring of myocardial ischemia. Two previously described systems for alternate limb lead placement were studied in patients with and without QRS evidence of healed anterior or inferior myocardial infarction. An innovative method was used to simultaneously record 6 standard and 6 modified limb leads, and 3 standard and 3 modified precordial leads on a standard digital electrocardiograph. Both alternate lead placement systems showed rightward frontal plane axis shift and diminished Q-wave durations in lead aVF compared with those of their simultaneous standard controls. Furthermore, potential differences between the standard distal limb lead sites and 5 more proximal sites were explored along each limb. Differences along the left arm were accentuated relative to those along the right arm owing to differences in proximity of the arms to the myocardium. Along the lower limb, and anterior site showed less deviation from standard than did a more lateral site. It is imperative that recordings from alternate sites be labeled accordingly so that their output cannot be confused with that obtained from standard sites.

Entities:  

Mesh:

Year:  1992        PMID: 1731468     DOI: 10.1016/0002-9149(92)91315-u

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  9 in total

Review 1.  Technical mistakes during the acquisition of the electrocardiogram.

Authors:  Javier García-Niebla; Pablo Llontop-García; Juan Ignacio Valle-Racero; Guillem Serra-Autonell; Velislav N Batchvarov; Antonio Bayés de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-10       Impact factor: 1.468

2.  High-risk electrocardiographic parameters are ubiquitous in patients with ischemic cardiomyopathy.

Authors:  Mary G Carey; Salah S Al-Zaiti; John M Canty; James A Fallavollita
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-07       Impact factor: 1.468

Review 3.  12-lead Holter electrocardiography. Review of the literature and clinical application update.

Authors:  Li Su; Stefan Borov; Bernhard Zrenner
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-06-19

Review 4.  Remote and wearable ECG devices with diagnostic abilities in adults: A state-of-the-science scoping review.

Authors:  Zeineb Bouzid; Salah S Al-Zaiti; Raymond Bond; Ervin Sejdić
Journal:  Heart Rhythm       Date:  2022-03-09       Impact factor: 6.779

5.  A new electrode placement method for obtaining 12-lead ECGs.

Authors:  Gabriel M Khan
Journal:  Open Heart       Date:  2015-06-09

6.  Atrial Fibrillation Screening in Nonmetropolitan Areas Using a Telehealth Surveillance System With an Embedded Cloud-Computing Algorithm: Prospective Pilot Study.

Authors:  Juey-Jen Hwang; Yi-Lwun Ho; Ying-Hsien Chen; Chi-Sheng Hung; Ching-Chang Huang; Yu-Chien Hung
Journal:  JMIR Mhealth Uhealth       Date:  2017-09-26       Impact factor: 4.773

7.  True unipolar ECG machine for Wilson Central Terminal measurements.

Authors:  Gaetano D Gargiulo
Journal:  Biomed Res Int       Date:  2015-10-01       Impact factor: 3.411

8.  Normal limits of ECG measurements related to atrial activity using a modified limb lead system.

Authors:  Jayaraman Sivaraman; Gandhi Uma; Sangareddi Venkatesan; Mangalanathan Umapathy; Vella Elumalai Dhandapani
Journal:  Anatol J Cardiol       Date:  2014-02-26       Impact factor: 1.596

9.  Modified limb lead ECG system effects on electrocardiographic wave amplitudes and frontal plane axis in sinus rhythm subjects.

Authors:  Sivaraman Jayaraman; Venkatesan Sangareddi; R Periyasamy; Justin Joseph; Ravi Marimuthu Shanmugam
Journal:  Anatol J Cardiol       Date:  2016-06-29       Impact factor: 1.596

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.