Literature DB >> 17314373

Sensitive and rapid detection of Vero toxin-producing Escherichia coli using loop-mediated isothermal amplification.

Yukiko Hara-Kudo1, Jiro Nemoto2, Kayoko Ohtsuka3, Yuko Segawa1, Kosuke Takatori1, Tadashi Kojima2, Masanari Ikedo2.   

Abstract

A loop-mediated isothermal amplification (LAMP) assay was developed to detect Vero toxin (VT)-producing Escherichia coli rapidly (within 60 min). The 24 strains of VT-producing E. coli were successfully amplified, but 6 strains of non-VT-producing E. coli and 46 bacterial species other than E. coli were not. The sensitivity of the LAMP assay was found to be >0.7 c.f.u. per test using serogroups O157, O26 and O111 of VT-producing E. coli; this sensitivity is greater than that obtained by PCR assay. Furthermore, the LAMP assay was examined for its ability to detect VT-producing E. coli in food because of the difficulty of detection in food samples. The recovery of VT-producing E. coli by LAMP assay from beef and radish sprouts inoculated with the pathogen was high, similar to that obtained using culture methods with direct plating and/or plating after immunomagnetic separation. Although PCR assay was unable to recover VT-producing E. coli from half of the radish samples, LAMP assay was successful in most samples. In addition, VT-producing E. coli was successfully detected in cultures of the beef samples by LAMP assay, but not by the culture method. The LAMP products in naturally contaminated beef samples were analysed to confirm the specific amplification of the VT-encoding gene, and were found to show a specific ladder band pattern on agarose gel after electrophoresis. Additionally the sequences of the LAMP products coincided well with the expected sequences of the VT-encoding gene. These results indicate that the proposed LAMP assay is a rapid, specific and sensitive method of detecting the VT-producing E. coli.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17314373     DOI: 10.1099/jmm.0.46819-0

Source DB:  PubMed          Journal:  J Med Microbiol        ISSN: 0022-2615            Impact factor:   2.472


  20 in total

1.  Rapid and sensitive detection of Listeria monocytogenes by loop-mediated isothermal amplification.

Authors:  Meng-Jun Tang; Sheng Zhou; Xiao-Yan Zhang; Jun-Hua Pu; Qing-Lian Ge; Xiu-Jun Tang; Yu-Shi Gao
Journal:  Curr Microbiol       Date:  2011-09-21       Impact factor: 2.188

2.  Rapid detection of viable salmonellae in produce by coupling propidium monoazide with loop-mediated isothermal amplification.

Authors:  Siyi Chen; Fei Wang; John C Beaulieu; Rebecca E Stein; Beilei Ge
Journal:  Appl Environ Microbiol       Date:  2011-04-15       Impact factor: 4.792

3.  Evaluation of a loop-mediated isothermal amplification suite for the rapid, reliable, and robust detection of Shiga toxin-producing Escherichia coli in produce.

Authors:  Fei Wang; Qianru Yang; Yinzhi Qu; Jianghong Meng; Beilei Ge
Journal:  Appl Environ Microbiol       Date:  2014-02-07       Impact factor: 4.792

4.  Viable but Nonculturable Escherichia coli O157:H7 and Salmonella enterica in Fresh Produce: Rapid Determination by Loop-Mediated Isothermal Amplification Coupled with a Propidium Monoazide Treatment.

Authors:  Lu Han; Kaidi Wang; Lina Ma; Pascal Delaquis; Susan Bach; Jinsong Feng; Xiaonan Lu
Journal:  Appl Environ Microbiol       Date:  2020-03-18       Impact factor: 4.792

5.  Loop-mediated isothermal amplification assays for detecting shiga toxin-producing Escherichia coli in ground beef and human stools.

Authors:  Fei Wang; Lin Jiang; Beilei Ge
Journal:  J Clin Microbiol       Date:  2011-10-26       Impact factor: 5.948

6.  Detecting potentially virulent Vibrio vulnificus strains in raw oysters by quantitative loop-mediated isothermal amplification.

Authors:  Feifei Han; Fei Wang; Beilei Ge
Journal:  Appl Environ Microbiol       Date:  2011-02-25       Impact factor: 4.792

7.  Rapid and specific detection of escherichia coli serogroups O26, O45, O103, O111, O121, O145, and O157 in ground beef, beef trim, and produce by loop-mediated isothermal amplification.

Authors:  Fei Wang; Lin Jiang; Qianru Yang; Witoon Prinyawiwatkul; Beilei Ge
Journal:  Appl Environ Microbiol       Date:  2012-02-10       Impact factor: 4.792

8.  Comparison of loop-mediated isothermal amplification assay and conventional culture methods for detection of Campylobacter jejuni and Campylobacter coli in naturally contaminated chicken meat samples.

Authors:  Wataru Yamazaki; Masumi Taguchi; Takao Kawai; Kentaro Kawatsu; Junko Sakata; Kiyoshi Inoue; Naoaki Misawa
Journal:  Appl Environ Microbiol       Date:  2009-01-09       Impact factor: 4.792

9.  Loop-mediated isothermal amplification assay for rapid detection of common strains of Escherichia coli.

Authors:  Joshua Hill; Shilpa Beriwal; Ishwad Chandra; Vinod K Paul; Aarti Kapil; Tripti Singh; Robert M Wadowsky; Vinita Singh; Ankur Goyal; Timo Jahnukainen; James R Johnson; Phillip I Tarr; Abhay Vats
Journal:  J Clin Microbiol       Date:  2008-06-11       Impact factor: 5.948

Review 10.  Lab-on-a-chip pathogen sensors for food safety.

Authors:  Jeong-Yeol Yoon; Bumsang Kim
Journal:  Sensors (Basel)       Date:  2012-08-06       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.