Literature DB >> 17309356

Development of a nonintrusive blood pressure estimation system for computer users.

Jungsoo Kim1, Juwan Park, Kokeun Kim, Youngjoon Chee, Yonggyu Lim, Kwangsuk Park.   

Abstract

An individual's cardiovascular health is important. The measurement of blood pressure (BP) can be performed nonintrusively during normal daily activities. A study was designed to estimate systolic BP by measuring pulse arrival time (PAT) nonintrusively. PAT was obtained nonintrusively to estimate each individual's BP while he or she worked at a computer. Electrocardiogram (ECG) was measured with a capacitive-coupled electrocardiogram (CC-ECG) system and photoplethysmogram (PPG) was measured using specially installed circuits in a computer mouse. PAT was calculated from CC-ECG and PPG, and compared to PAT measured by the standard method. Three individuals participated in this study. Results correlated well. An equation to estimate BP from the measured PAT was derived for each of three individuals during a training period. Estimated BP was compared with measured BP in a series of experiments under varied BP conditions. For each individual, the estimated BP followed the measured BP within a tolerable error range. This method was also used for long-term BP monitoring. Results showed that this method could be useful for monitoring BP for telemedicine and e-health.

Entities:  

Mesh:

Year:  2007        PMID: 17309356     DOI: 10.1089/tmj.2006.0034

Source DB:  PubMed          Journal:  Telemed J E Health        ISSN: 1530-5627            Impact factor:   3.536


  8 in total

1.  Validation of new and existing decision rules for the estimation of beat-to-beat pulse transit time.

Authors:  Xiaolin Zhou; Rongchao Peng; Hongxia Ding; Ningling Zhang; Pan Li
Journal:  Biomed Res Int       Date:  2015-03-02       Impact factor: 3.411

2.  Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms.

Authors:  Jeong Su Lee; Jeong Heo; Won Kyu Lee; Yong Gyu Lim; Youn Ho Kim; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2014-08-12       Impact factor: 3.576

3.  Application of Handheld Tele-ECG for Health Care Delivery in Rural India.

Authors:  Meenu Singh; Amit Agarwal; Vineet Sinha; Rohit Manoj Kumar; Nishant Jaiswal; Ishita Jindal; Pankaj Pant; Munish Kumar
Journal:  Int J Telemed Appl       Date:  2014-09-28

4.  Heart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed.

Authors:  Hong Ji Lee; Su Hwan Hwang; Hee Nam Yoon; Won Kyu Lee; Kwang Suk Park
Journal:  Sensors (Basel)       Date:  2015-05-14       Impact factor: 3.576

Review 5.  New Approaches in Hypertension Management: a Review of Current and Developing Technologies and Their Potential Impact on Hypertension Care.

Authors:  Jamie Kitt; Rachael Fox; Katherine L Tucker; Richard J McManus
Journal:  Curr Hypertens Rep       Date:  2019-04-25       Impact factor: 5.369

6.  An Optimization Study of Estimating Blood Pressure Models Based on Pulse Arrival Time for Continuous Monitoring.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Yang Liu; Hongliu Yu
Journal:  J Healthc Eng       Date:  2020-02-10       Impact factor: 2.682

Review 7.  Novel Digital Technologies for Blood Pressure Monitoring and Hypertension Management.

Authors:  Allison J Hare; Neel Chokshi; Srinath Adusumalli
Journal:  Curr Cardiovasc Risk Rep       Date:  2021-06-09

8.  Calibration-Free Cuffless Blood Pressure Estimation Based on a Population With a Diverse Range of Age and Blood Pressure.

Authors:  Syunsuke Yamanaka; Koji Morikawa; Hiroshi Morita; Ji Young Huh; Osamu Yamamura
Journal:  Front Med Technol       Date:  2021-07-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.