Lower body mass index and atrial fibrillation as independent predictors for mortality in patients with implantable cardioverter defibrillator.

Christiana Schernthaner1, Maximilian Pichler, Bernhard Strohmer.   

Abstract

AIM: To evaluate risk factors related to total mortality in an unselected population of patients implanted with a cardioverter defibrillator.
METHODS: Survival analysis was performed retrospectively investigating the records of 77 consecutive patients implanted with defibrillators (median 67 years, range 38-83 years; 63 men). All patients were followed regularly in 3-month intervals. The cause of mortality was assessed clinically, including post-mortem examination of device to assess possible arrhythmogenic death. Predictors were assessed by Kaplan-Meier analysis with log-rank tests and by Cox regression analysis (proportional hazards).
RESULTS: Defibrillator recipients had a mean (+/-standard deviation) ejection fraction of 34+/-13%, left ventricular end-diastolic dimension (LVEDD) of 6.24+/-0.8 cm, QRS duration of 129+/-34 ms, and body mass index (BMI) of 26.4+/-4.3 kg/m(2). Atrial fibrillation was present in 32 patients, paroxysmal fibrillation in 23, and permanent fibrillation in 9 patients. The estimate of mean survival time for all patients was 51.5 (95% confidence interval 46.6-56.5) months. During the study period 11/77 (14%) patients died. Mean follow-up time was 24.5 months (range 0.2-60.7) for survivors and 7.6 months (range 1.5-42) for non-survivors. Independent predictors of mortality were the NYHA class (P=0.004), BMI< or =26 kg/m(2) (P=0.024), presence of paroxysmal or permanent atrial fibrillation (P=0.014), and absence of arterial hypertension (P=0.010). LVEDD showed a weak significant effect on survival (P=0.049).
CONCLUSION: Patients with implantable cardioverter defibrillator and a normal to lower BMI or atrial fibrillation had a significantly higher overall mortality. These factors may be indicative of end stage heart failure or diseases associated with high sympathetic activation.

Entities:  

Mesh:

Year:  2007        PMID: 17309140      PMCID: PMC2080502     

Source DB:  PubMed          Journal:  Croat Med J        ISSN: 0353-9504            Impact factor:   1.351


  30 in total

1.  Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction.

Authors:  Stefan H Hohnloser; Karl Heinz Kuck; Paul Dorian; Robin S Roberts; John R Hampton; Robert Hatala; Eric Fain; Michael Gent; Stuart J Connolly
Journal:  N Engl J Med       Date:  2004-12-09       Impact factor: 91.245

2.  Factors influencing appropriate firing of the implanted defibrillator for ventricular tachycardia/fibrillation: findings from the Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II).

Authors:  Jagmeet P Singh; W Jackson Hall; Scott McNitt; Hongyue Wang; James P Daubert; Wojciech Zareba; Jeremy N Ruskin; Arthur J Moss
Journal:  J Am Coll Cardiol       Date:  2005-10-10       Impact factor: 24.094

3.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.

Authors:  Gust H Bardy; Kerry L Lee; Daniel B Mark; Jeanne E Poole; Douglas L Packer; Robin Boineau; Michael Domanski; Charles Troutman; Jill Anderson; George Johnson; Steven E McNulty; Nancy Clapp-Channing; Linda D Davidson-Ray; Elizabeth S Fraulo; Daniel P Fishbein; Richard M Luceri; John H Ip
Journal:  N Engl J Med       Date:  2005-01-20       Impact factor: 91.245

4.  The prognosis of heart failure in the general population: The Rotterdam Study.

Authors:  A Mosterd; B Cost; A W Hoes; M C de Bruijne; J W Deckers; A Hofman; D E Grobbee
Journal:  Eur Heart J       Date:  2001-08       Impact factor: 29.983

5.  The relationship between obesity and mortality in patients with heart failure.

Authors:  T B Horwich; G C Fonarow; M A Hamilton; W R MacLellan; M A Woo; J H Tillisch
Journal:  J Am Coll Cardiol       Date:  2001-09       Impact factor: 24.094

6.  Predicting early mortality after implantable defibrillator implantation: a clinical risk score for optimal patient selection.

Authors:  Ratika Parkash; William G Stevenson; Laurence M Epstein; William H Maisel
Journal:  Am Heart J       Date:  2006-02       Impact factor: 4.749

7.  Body-mass index and mortality in a prospective cohort of U.S. adults.

Authors:  E E Calle; M J Thun; J M Petrelli; C Rodriguez; C W Heath
Journal:  N Engl J Med       Date:  1999-10-07       Impact factor: 91.245

8.  Heart failure in the general population of men--morbidity, risk factors and prognosis.

Authors:  L Wilhelmsen; A Rosengren; H Eriksson; G Lappas
Journal:  J Intern Med       Date:  2001-03       Impact factor: 8.989

9.  Reduction in ventricular tachyarrhythmias with statins in the Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II.

Authors:  Anant K Vyas; Hongsheng Guo; Arthur J Moss; Brian Olshansky; Scott A McNitt; W Jackson Hall; Wojciech Zareba; Jonathan S Steinberg; Avi Fischer; Jeremy Ruskin; Mark L Andrews
Journal:  J Am Coll Cardiol       Date:  2006-01-30       Impact factor: 24.094

10.  Atrial fibrillation is associated with an increased risk for mortality and heart failure progression in patients with asymptomatic and symptomatic left ventricular systolic dysfunction: a retrospective analysis of the SOLVD trials. Studies of Left Ventricular Dysfunction.

Authors:  D L Dries; D V Exner; B J Gersh; M J Domanski; M A Waclawiw; L W Stevenson
Journal:  J Am Coll Cardiol       Date:  1998-09       Impact factor: 24.094

View more
  3 in total

1.  Frailty, Implantable Cardioverter Defibrillators, and Mortality: a Systematic Review.

Authors:  Michael Y Chen; Ariela R Orkaby; Michael A Rosenberg; Jane A Driver
Journal:  J Gen Intern Med       Date:  2019-07-01       Impact factor: 5.128

2.  Atrial Fibrillation Is Associated With Higher Overall Mortality in Patients With Implantable Cardioverter-Defibrillator: A Systematic Review and Meta-Analysis.

Authors:  Usman Mustafa; Parinita Dherange; Rohit Reddy; Joseph DeVillier; Jessica Chong; Alarozia Ihsan; Ryan Jones; Narendra Duddyala; Pratap Reddy; Paari Dominic
Journal:  J Am Heart Assoc       Date:  2018-11-20       Impact factor: 5.501

3.  Predictors of early mortality in implantable cardioverter-defibrillator recipients.

Authors:  Kenneth M Stein; Suneet Mittal; F Roosevelt Gilliam; David M Gilligan; Qian Zhong; Stacia Merkel Kraus; Timothy E Meyer
Journal:  Europace       Date:  2009-03-11       Impact factor: 5.214

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.