BACKGROUND:Patients with advanced heart disease are at risk from sudden death; however, benefit from implantable cardioverter defibrillators (ICDs) may be limited as a result of early mortality from other causes. The objective of this study was to develop a model to predict mortality within the first year after ICD implantation. METHODS AND RESULTS: A retrospective analysis was performed of 469 consecutive patients who underwent ICD implantation at a single tertiary-care center from 1999 to 2002. Vital status was determined from the Social Security Death Index. Patients were randomized into prediction and validation cohorts. A risk score was derived from the prediction cohort by multivariate logistic regression and applied to the validation cohort. One point was assigned for each variable in the risk score (age > 80 years, history of atrial fibrillation, creatinine > 1.8 mg/dL, New York Heart Association class III or IV). One-year mortality significantly increased with increasing risk score in both the prediction and validation cohorts. Validation cohort mortality was 3.4% for 0 points, 4.3% for 1 point, 17% for 2 points, and 33% for > or = 3 points (P for trend < .0001). A risk score > or = 2 predicted a 1-year mortality rate of 21%, whereas a risk score < 2 predicted a mortality rate of 4% at 1 year (P < .0001). CONCLUSION: A risk score using simple clinical criteria may identify patients at high risk of early mortality after ICD implantation. This may be helpful in consideration of ICD risk/benefit for individual patients. Further studies conducted in a prospective manner using these clinical criteria are warranted.
RCT Entities:
BACKGROUND:Patients with advanced heart disease are at risk from sudden death; however, benefit from implantable cardioverter defibrillators (ICDs) may be limited as a result of early mortality from other causes. The objective of this study was to develop a model to predict mortality within the first year after ICD implantation. METHODS AND RESULTS: A retrospective analysis was performed of 469 consecutive patients who underwent ICD implantation at a single tertiary-care center from 1999 to 2002. Vital status was determined from the Social Security Death Index. Patients were randomized into prediction and validation cohorts. A risk score was derived from the prediction cohort by multivariate logistic regression and applied to the validation cohort. One point was assigned for each variable in the risk score (age > 80 years, history of atrial fibrillation, creatinine > 1.8 mg/dL, New York Heart Association class III or IV). One-year mortality significantly increased with increasing risk score in both the prediction and validation cohorts. Validation cohort mortality was 3.4% for 0 points, 4.3% for 1 point, 17% for 2 points, and 33% for > or = 3 points (P for trend < .0001). A risk score > or = 2 predicted a 1-year mortality rate of 21%, whereas a risk score < 2 predicted a mortality rate of 4% at 1 year (P < .0001). CONCLUSION: A risk score using simple clinical criteria may identify patients at high risk of early mortality after ICD implantation. This may be helpful in consideration of ICD risk/benefit for individual patients. Further studies conducted in a prospective manner using these clinical criteria are warranted.
Authors: Daniel B Kramer; Daniel D Matlock; Alfred E Buxton; Nathan E Goldstein; Carol Goodwin; Ariel R Green; James N Kirkpatrick; Christopher Knoepke; Rachel Lampert; Paul S Mueller; Matthew R Reynolds; John A Spertus; Lynne W Stevenson; Susan L Mitchell Journal: Circ Cardiovasc Qual Outcomes Date: 2015-06-02
Authors: Yiyi Zhang; Eliseo Guallar; Elena Blasco-Colmenares; Darshan Dalal; Barbara Butcher; Sanaz Norgard; Fleur V Y Tjong; Zayd Eldadah; Timm Dickfeld; Kenneth A Ellenbogen; Joseph E Marine; Gordon F Tomaselli; Alan Cheng Journal: Heart Rhythm Date: 2014-10-30 Impact factor: 6.343
Authors: Daniel B Kramer; Kevin F Kennedy; John A Spertus; Sharon-Lise Normand; Peter A Noseworthy; Alfred E Buxton; Mark E Josephson; Peter J Zimetbaum; Susan L Mitchell; Matthew R Reynolds Journal: Heart Rhythm Date: 2014-02 Impact factor: 6.343