Literature DB >> 17302706

Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database.

Arnaud Lazarus1.   

Abstract

STUDY
OBJECTIVE: To describe the daily routine application of a new telemonitoring system in a large population of cardiac device recipients.
METHODS: Data transmitted daily and automatically by a remote, wireless Home Monitoring system (HM) were analyzed. The average time gained in the detection of events using HM versus standard practice and the impact of HM on physician workload were examined. The mean interval between device interrogations was used to compare the rates of follow-up visits versus that recommended in guidelines.
RESULTS: 3,004,763 transmissions were made by 11,624 recipients of pacemakers (n = 4,631), defibrillators (ICD; n = 6,548), and combined ICD + cardiac resynchronization therapy (CRT-D) systems (n = 445) worldwide. The duration of monitoring/patient ranged from 1 to 49 months, representing 10,057 years. The vast majority (86%) of events were disease-related. The mean interval between last follow-up and occurrence of events notified by HM was 26 days, representing a putative temporal gain of 154 and 64 days in patients usually followed at 6- and 3-month intervals, respectively. The mean numbers of events per patient per month reported to the caregivers for the overall population was 0.6. On average, 47.6% of the patients were event-free. The mean interval between follow-up visits in patients with pacemakers, single-chamber ICDs, dual chamber ICDs, and CRT-D systems were 5.9 +/- 2.1, 3.6 +/- 3.3, 3.3 +/- 3.5, and 1.9 +/- 2.9 months, respectively.
CONCLUSIONS: This broad clinical application of a new monitoring system strongly supports its capability to improve the care of cardiac device recipients, enhance their safety, and optimize the allocation of health resources.

Entities:  

Mesh:

Year:  2007        PMID: 17302706     DOI: 10.1111/j.1540-8159.2007.00595.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  45 in total

1.  ISHNE/EHRA expert consensus on remote monitoring of cardiovascular implantable electronic devices (CIEDs).

Authors:  Sergio Dubner; Angelo Auricchio; Jonathan S Steinberg; Panos Vardas; Peter Stone; Josep Brugada; Ryszard Piotrowicz; David L Hayes; Paulus Kirchhof; Günter Breithardt; Wojciech Zareba; Claudio Schuger; Mehmet K Aktas; Michal Chudzik; Suneet Mittal; Niraj Varma
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-01       Impact factor: 1.468

2.  Workload, time and costs of the informal cares in patients with tele-monitoring of pacemakers: the PONIENTE study.

Authors:  Antonio López-Villegas; Daniel Catalán-Matamoros; Emilio Robles-Musso; Salvador Peiró
Journal:  Clin Res Cardiol       Date:  2015-09-30       Impact factor: 5.460

3.  [Home monitoring of an incessant VT in an ICD patient].

Authors:  N Reinsch; D Woydowski; H Schön; M Buddensiek; W Weissenberger; R Erbel; T Konorza
Journal:  Herz       Date:  2010-12-23       Impact factor: 1.443

4.  Remote monitoring in implantable defibrillator therapy.

Authors:  D A M J Theuns; L S Jordaens
Journal:  Neth Heart J       Date:  2008-02       Impact factor: 2.380

Review 5.  Advances in remote monitoring of implantable pacemakers, cardioverter defibrillators and cardiac resynchronization therapy systems.

Authors:  Werner Jung; Andreas Rillig; Ralf Birkemeyer; Tomislav Miljak; Udo Meyerfeldt
Journal:  J Interv Card Electrophysiol       Date:  2008-09-27       Impact factor: 1.900

6.  Remote monitoring of implanted cardiac devices: a plea for a nationwide exploration.

Authors:  N M van Hemel
Journal:  Neth Heart J       Date:  2009-11       Impact factor: 2.380

Review 7.  [ECG telemonitoring].

Authors:  Michael Oeff; Axel Müller; Jörg Neuzner; Stefan Sack; Jörg O Schwab; Dietrich Pfeiffer; Christian Zugck
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-10-25

8.  Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory.

Authors:  Laurence Guédon-Moreau; Philippe Chevalier; Christelle Marquié; Claude Kouakam; Didier Klug; Dominique Lacroix; Francois Brigadeau; Salem Kacet
Journal:  Eur Heart J       Date:  2010-06-30       Impact factor: 29.983

9.  [Telemedicine in pacemaker therapy and follow-up].

Authors:  A Schuchert
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-12

10.  Design of the evolution of management strategies of heart failure patients with implantable defibrillators (EVOLVO) study to assess the ability of remote monitoring to treat and triage patients more effectively.

Authors:  Maurizio Marzegalli; Maurizio Landolina; Maurizio Lunati; Giovanni B Perego; Alessia Pappone; Giuseppe Guenzati; Carlo Campana; Maria Frigerio; Gianfranco Parati; Antonio Curnis; Irene Colangelo; Sergio Valsecchi
Journal:  Trials       Date:  2009-06-18       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.