Literature DB >> 17301469

Implementation of an iterative scatter correction, the influence of attenuation map quality and their effect on absolute quantitation in SPECT.

Eric Vandervoort1, Anna Celler, Ronald Harrop.   

Abstract

We investigated the accuracy of qSPECT, a quantitative SPECT reconstruction algorithm we have developed which employs corrections for collimator blurring, photon attenuation and scatter, and provides images in units of absolute radiotracer concentrations (kBq cm(-3)). Using simulated and experimental phantom data with characteristics similar to clinical cardiac perfusion data, we studied the implementation of a scatter correction (SC) as part of an iterative reconstruction protocol. Additionally, with experimental phantom studies we examined the influence of CT-based attenuation maps, relative to those obtained from conventional SPECT transmission scans, on SCs and quantitation. Our results indicate that the qSPECT estimated scatter corrections did not change appreciably after the third iteration of the reconstruction. For the simulated data, qSPECT concentrations agreed with images reconstructed using ideal, scatter-free, simulated data to within 6%. For the experimental data, we observed small systematic differences in the scatter fractions for data using different combinations of SCs and attenuation maps. The SCs were found to be significantly influenced by errors in image coregistration. The reconstructed concentrations using CT-based corrections were more quantitatively accurate than those using attenuation maps from conventional SPECT transmission scans. However, segmenting the attenuation maps from SPECT transmission scans could provide sufficient accuracy for most applications.

Mesh:

Year:  2007        PMID: 17301469     DOI: 10.1088/0031-9155/52/5/020

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Attenuation correction for lung SPECT: evidence of need and validation of an attenuation map derived from the emission data.

Authors:  Margarita Núñez; Vineet Prakash; Ricardo Vila; Fernando Mut; Omar Alonso; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-02-24       Impact factor: 9.236

2.  An investigation of potential sources of artifacts in SPECT-CT myocardial perfusion studies.

Authors:  Anna Celler; Sergey Shcherbinin; Tyler Hughes
Journal:  J Nucl Cardiol       Date:  2009-12-12       Impact factor: 5.952

Review 3.  Clinical Applications of Technetium-99m Quantitative Single-Photon Emission Computed Tomography/Computed Tomography.

Authors:  Won Woo Lee
Journal:  Nucl Med Mol Imaging       Date:  2019-03-15

Review 4.  Absolute quantification in SPECT.

Authors:  Philipp Ritt; Hans Vija; Joachim Hornegger; Torsten Kuwert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

5.  In vivo tumor grading of prostate cancer using quantitative 111In-capromab pendetide SPECT/CT.

Authors:  Youngho Seo; Carina Mari Aparici; Matthew R Cooperberg; Badrinath R Konety; Randall A Hawkins
Journal:  J Nucl Med       Date:  2009-12-15       Impact factor: 10.057

6.  Quantitative (177)Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT system.

Authors:  Jean-Mathieu Beauregard; Michael S Hofman; Jucilene M Pereira; Peter Eu; Rodney J Hicks
Journal:  Cancer Imaging       Date:  2011-06-15       Impact factor: 3.909

7.  Quantitative evaluation of scintillation camera imaging characteristics of isotopes used in liver radioembolization.

Authors:  Mattijs Elschot; Johannes Franciscus Wilhelmus Nijsen; Alida Johanna Dam; Hugo Wilhelmus Antonius Maria de Jong
Journal:  PLoS One       Date:  2011-11-03       Impact factor: 3.240

8.  Accuracy of 177Lu activity quantification in SPECT imaging: a phantom study.

Authors:  Carlos F Uribe; Pedro L Esquinas; Jesse Tanguay; Marjorie Gonzalez; Emilie Gaudin; Jean-Mathieu Beauregard; Anna Celler
Journal:  EJNMMI Phys       Date:  2017-01-07

9.  Towards standardization of absolute SPECT/CT quantification: a multi-center and multi-vendor phantom study.

Authors:  Steffie M B Peters; Niels R van der Werf; Marcel Segbers; Floris H P van Velden; Roel Wierts; Koos J A K Blokland; Mark W Konijnenberg; Sergiy V Lazarenko; Eric P Visser; Martin Gotthardt
Journal:  EJNMMI Phys       Date:  2019-12-26

10.  Analysis of quantitative [I-123] mIBG SPECT/CT in a phantom and in patients with neuroblastoma.

Authors:  Samuel L Brady; Barry L Shulkin
Journal:  EJNMMI Phys       Date:  2019-12-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.