Assessing image quality in effective Poisson's ratio elastography and poroelastography: II.

Raffaella Righetti1, Jonathan Ophir, Arun Thitai Kumar, Thomas A Krouskop.   

Abstract

Poroelastography is a novel elastographic technique for imaging the time variation of the mechanical behaviour of poroelastic materials. Poroelastograms are generated as a series of time-sequenced effective Poisson's ratio (EPR) elastograms, obtained from the imaged material under sustained compression. In the companion report (Righetti et al 2007 Phys. Med. Biol. 52 1303), we investigated image quality of EPR elastography starting from a theoretical analysis of the performance limitations of axial strain elastography and lateral strain elastography. In this report, we extend this analysis to poroelastography. The theoretical analysis reported in these two companion papers allows understanding the performance limitations of these novel techniques and identifying the fundamental parameters that control their signal-to-noise ratio, contrast-to-noise ratio and resolution. The results of these studies also indicate that EPR elastograms and poroelastograms of reasonable image quality can be generated in practical applications that may be of clinical interest provided that advanced elastographic techniques in combination with other commonly employed imaging methods to increase signal-to-noise and contrast-to-noise ratios are used.

Mesh:

Year:  2007        PMID: 17301457     DOI: 10.1088/0031-9155/52/5/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

2.  The shear modulus of the nucleus pulposus measured using magnetic resonance elastography: a potential biomarker for intervertebral disc degeneration.

Authors:  Daniel H Cortes; Jeremy F Magland; Alexander C Wright; Dawn M Elliott
Journal:  Magn Reson Med       Date:  2013-07-31       Impact factor: 4.668

3.  Modeling of soft poroelastic tissue in time-harmonic MR elastography.

Authors:  Phillip R Perriñez; Francis E Kennedy; Elijah E W Van Houten; John B Weaver; Keith D Paulsen
Journal:  IEEE Trans Biomed Eng       Date:  2008-12-02       Impact factor: 4.538

4.  Further characterization of changes in axial strain elastograms due to the presence of slippery tumor boundaries.

Authors:  Christopher Uff; Leo Garcia; Jeremie Fromageau; Aabir Chakraborty; Neil Dorward; Jeffrey Bamber
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.