Literature DB >> 1729871

Establishing comprehensive, quantitative criteria for detection of restenosis and remodeling after percutaneous transluminal coronary angioplasty.

N B de Cesare1, P R Williamson, N B Moore, S F DeBoe, G B Mancini.   

Abstract

To establish comprehensive criteria for detecting restenosis and remodeling, inter- and intraobserver reproducibility of quantitative arteriography in the analysis of 20 lesions immediately after and 6 months after percutaneous transluminal coronary angioplasty (PTCA) were assessed. Geometric single-plane (minimum, maximum, mean diameter and percent diameter stenosis), biplane (absolute and relative cross-sectional area stenosis), relative densitometric area stenosis and the average of densitometric area stenosis in orthogonal views were compared. A high intra- and interobserver reproducibility of all absolute measurements was found, with the highest correlations for minimum diameter and cross-sectional area (interobserver, r = 0.85 and 0.85; intraobserver, r = 0.93, and 0.95 for minimum diameter and cross-sectional area, respectively). Of the relative measurements, biplane geometric percent cross-sectional area stenosis was the most reliable and percent densitometric area stenosis was the most variable (interobserver, r = 0.67; intraobserver, r = 0.71). Only small differences were demonstrated for the absolute measurements between the analysis of lesions immediately after PTCA and after follow-up, whereas a greater variability was found for relative measurements, especially videodensitometry. In both circumstances, a poor correlation between relative densitometric cross-sectional area from orthogonal views was found, whereas geometric elliptical cross-sectional area correlated quite well with the average of densitometric percent cross-sectional area in orthogonal views (interobserver, r = 0.86; intraobserver, r = 0.84). Thus, data in this study support the suitability of geometric quantitative analysis for the assessment of PTCA results. Densitometry was the least reliable quantitative parameter.

Entities:  

Mesh:

Year:  1992        PMID: 1729871     DOI: 10.1016/0002-9149(92)90679-s

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  1 in total

1.  Intra- and interobserver variability of a fast on-line quantitative coronary angiographic system.

Authors:  W Desmet; J L Willems; M Vrolix; J van Lierde; G Byttebier; J Piessens
Journal:  Int J Card Imaging       Date:  1993-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.