Literature DB >> 17298409

Modular hip stems: determination of disassembly force of a neck-stem coupling.

Francesco Pallini1, Luca Cristofolini, Francesco Traina, Aldo Toni.   

Abstract

An increasing number of hip prostheses feature double head-neck and neck-stem modularities. One possible complication is loosening of the neck-stem coupling. Current surgical technique includes application of hammer blows to the proximal end of the neck-stem coupling. This could compromise the cleanness of the head-neck modularity and damage the bearing surfaces. The goal of this work was to assess whether such hammer blows are really necessary to avoid neck-stem disassembly during in vivo service. Commercially available hip stems featuring neck-stem modularity were tested. Extraction force was measured in vitro when different levels of press fitting were simulated (manual assembly followed by various combinations of simulated loads) to assess critical conditions in relation to surgical technique and applied loads. The disassembly force after manual insertion followed by the first small postoperative loads imposed by the patient during walking was as high as that obtained with hammer blows. Thus, application of hammer blows to fix the neck-stem coupling seemed unnecessary.

Entities:  

Mesh:

Year:  2007        PMID: 17298409     DOI: 10.1111/j.1525-1594.2007.00359.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  5 in total

1.  Outcomes of neck modularity in total hip arthroplasty: an Italian perspective.

Authors:  R Papalia; A Di Martino; A Caldaria; B Zampogna; V Denaro
Journal:  Musculoskelet Surg       Date:  2019-01-23

2.  Proximal component modularity in THA--at what cost? An implant retrieval study.

Authors:  A M Kop; C Keogh; E Swarts
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

3.  Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.

Authors:  A Kouzelis; C S Georgiou; P Megas
Journal:  J Orthop Traumatol       Date:  2011-12-08

4.  Late Onset Disassembly of a Modular Neck-stem Component after Cementless Hip Replacement without Dislocation: A Case Report and Review of Literatures.

Authors:  Ioannis Papaioannou; Thomas Repantis; Andreas Baikousis; Panagiotis Korovessis
Journal:  Hip Pelvis       Date:  2018-09-04

5.  Dual-taper modular hip implant: Investigation of 3-dimensional surface scans for component contact, shape, and fit.

Authors:  Nicholas B Frisch; Jonathan R Lynch; Robin Pourzal; Richard F Banglmaier; Craig D Silverton
Journal:  Arthroplast Today       Date:  2018-07-21
  5 in total