Literature DB >> 17293240

4D Proton treatment planning strategy for mobile lung tumors.

Yixiu Kang1, Xiaodong Zhang, Joe Y Chang, He Wang, Xiong Wei, Zhongxing Liao, Ritsuko Komaki, James D Cox, Peter A Balter, Helen Liu, X Ronald Zhu, Radhe Mohan, Lei Dong.   

Abstract

PURPOSE: To investigate strategies for designing compensator-based 3D proton treatment plans for mobile lung tumors using four-dimensional computed tomography (4DCT) images. METHODS AND MATERIALS: Four-dimensional CT sets for 10 lung cancer patients were used in this study. The internal gross tumor volume (IGTV) was obtained by combining the tumor volumes at different phases of the respiratory cycle. For each patient, we evaluated four planning strategies based on the following dose calculations: (1) the average (AVE) CT; (2) the free-breathing (FB) CT; (3) the maximum intensity projection (MIP) CT; and (4) the AVE CT in which the CT voxel values inside the IGTV were replaced by a constant density (AVE_RIGTV). For each strategy, the resulting cumulative dose distribution in a respiratory cycle was determined using a deformable image registration method.
RESULTS: There were dosimetric differences between the apparent dose distribution, calculated on a single CT dataset, and the motion-corrected 4D dose distribution, calculated by combining dose distributions delivered to each phase of the 4DCT. The AVE_RIGTV plan using a 1-cm smearing parameter had the best overall target coverage and critical structure sparing. The MIP plan approach resulted in an unnecessarily large treatment volume. The AVE and FB plans using 1-cm smearing did not provide adequate 4D target coverage in all patients. By using a larger smearing value, adequate 4D target coverage could be achieved; however, critical organ doses were increased.
CONCLUSION: The AVE_RIGTV approach is an effective strategy for designing proton treatment plans for mobile lung tumors.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17293240     DOI: 10.1016/j.ijrobp.2006.10.045

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  82 in total

1.  Robust optimization of intensity modulated proton therapy.

Authors:  Wei Liu; Xiaodong Zhang; Yupeng Li; Radhe Mohan
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Influence of robust optimization in intensity-modulated proton therapy with different dose delivery techniques.

Authors:  Wei Liu; Yupeng Li; Xiaoqiang Li; Wenhua Cao; Xiaodong Zhang
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

3.  Practical approaches to four-dimensional heavy-charged-particle lung therapy.

Authors:  Shinichiro Mori; Ziji Wu; Michael R Folkert; Motoki Kumagai; Suguru Dobashi; Toshio Sugane; Masayuki Baba
Journal:  Radiol Phys Technol       Date:  2009-10-14

4.  Density overwrites of internal tumor volumes in intensity modulated proton therapy plans for mobile lung tumors.

Authors:  Pablo Botas; Clemens Grassberger; Gregory Sharp; Harald Paganetti
Journal:  Phys Med Biol       Date:  2018-01-30       Impact factor: 3.609

5.  Proton Beam Radiotherapy and Concurrent Chemotherapy for Unresectable Stage III Non-Small Cell Lung Cancer: Final Results of a Phase 2 Study.

Authors:  Joe Y Chang; Vivek Verma; Ming Li; Wencheng Zhang; Ritsuko Komaki; Charles Lu; Pamela K Allen; Zhongxing Liao; James Welsh; Steven H Lin; Daniel Gomez; Melenda Jeter; Michael O'Reilly; Ronald X Zhu; Xiaodong Zhang; Heng Li; Radhe Mohan; John V Heymach; Ara A Vaporciyan; Stephen Hahn; James D Cox
Journal:  JAMA Oncol       Date:  2017-08-10       Impact factor: 31.777

6.  Four-dimensional Monte Carlo simulations demonstrating how the extent of intensity-modulation impacts motion effects in proton therapy lung treatments.

Authors:  Stephen Dowdell; Clemens Grassberger; Harald Paganetti
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

7.  Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate.

Authors:  Adam C Riegel; Moiz Ahmad; Xiaojun Sun; Tinsu Pan
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

8.  Determination of patient-specific internal gross tumor volumes for lung cancer using four-dimensional computed tomography.

Authors:  Muthuveni Ezhil; Sastry Vedam; Peter Balter; Bum Choi; Dragan Mirkovic; George Starkschall; Joe Y Chang
Journal:  Radiat Oncol       Date:  2009-01-27       Impact factor: 3.481

9.  Impact of Spot Size and Spacing on the Quality of Robustly Optimized Intensity Modulated Proton Therapy Plans for Lung Cancer.

Authors:  Chenbin Liu; Steven E Schild; Joe Y Chang; Zhongxing Liao; Shawn Korte; Jiajian Shen; Xiaoning Ding; Yanle Hu; Yixiu Kang; Sameer R Keole; Terence T Sio; William W Wong; Narayan Sahoo; Martin Bues; Wei Liu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-02-14       Impact factor: 7.038

10.  Four-dimensional deformable image registration using trajectory modeling.

Authors:  Edward Castillo; Richard Castillo; Josue Martinez; Maithili Shenoy; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

View more