Literature DB >> 17291015

Viscoelastic properties of fibrinogen adsorbed to the surface of biomaterials used in blood-contacting medical devices.

Norbert Weber1, Aaron Pesnell, Durgadas Bolikal, Joan Zeltinger, Joachim Kohn.   

Abstract

The hemocompatibility of polymeric vascular implants is in part dependent on the propensity of fibrinogen to adsorb to the implant surface. Fibrinogen surface adsorption was measured in real time using a quartz crystal microbalance with dissipation monitoring (QCM-D). Six new, biodegradable tyrosine-derived polycarbonates were used as test surfaces. Stainless steel, poly(L-lactic acid), poly(D,L-lactide-co-glycolide), and poly(ethylene terephthalate) surfaces served as controls and provided a comparison of the test surfaces with those of commonly used biomaterials. Our study addressed the question regarding to which extent systematic variations in polymer structure can be used to optimize X-ray visibility and provide tunable degradation rates while generating protein-repellant surface properties that minimize fibrinogen adsorption. QCM-D revealed surface-dependent changes in fibrinogen layer thickness (2 to 37 nm), adsorbed wet mass (0.2 to 4.3 microg/cm2), and viscosity (0.001 to 0.005 kg/ms). While we did not find an overall correlation between surface air-water contact angle measurements and fibrinogen adsorption (R2 = 0.08), our data demonstrate that gradually increasing the poly(ethylene glycol) content within a subgroup of polymers having the same polymer backbone will lead to decreased fibrinogen adsorption. Within this subgroup of polymers, there was a strong correlation between decreasing air-water contact angles and decreasing fibrinogen adsorption (R2 = 0.95). We conclude that it is possible to minimize fibrinogen adsorption to tyrosine-derived polycarbonates while optimizing X-ray visibility and degradation rates. Some of the tyrosine-derived polycarbonates were identified as useful materials for the design of blood-contacting implants on the basis of their substantially lower levels of fibrinogen adsorption relative to the commonly used controls.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17291015     DOI: 10.1021/la060500r

Source DB:  PubMed          Journal:  Langmuir        ISSN: 0743-7463            Impact factor:   3.882


  17 in total

Review 1.  Emerging applications of nanotechnology for the diagnosis and management of vulnerable atherosclerotic plaques.

Authors:  Shann S Yu; Ryan A Ortega; Brendan W Reagan; John A McPherson; Hak-Joon Sung; Todd D Giorgio
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2011-08-10

Review 2.  Quartz crystal microbalance with dissipation monitoring: enabling real-time characterization of biological materials and their interactions.

Authors:  Matthew C Dixon
Journal:  J Biomol Tech       Date:  2008-07

3.  Pro-angiogenic and anti-inflammatory regulation by functional peptides loaded in polymeric implants for soft tissue regeneration.

Authors:  Angela L Zachman; Spencer W Crowder; Ophir Ortiz; Katarzyna J Zienkiewicz; Christine M Bronikowski; Shann S Yu; Todd D Giorgio; Scott A Guelcher; Joachim Kohn; Hak-Joon Sung
Journal:  Tissue Eng Part A       Date:  2012-10-19       Impact factor: 3.845

4.  Influence of chirality on catalytic generation of nitric oxide and platelet behavior on selenocystine immobilized TiO2 films.

Authors:  Yonghong Fan; Xiaxin Pan; Ke Wang; Sisi Wu; Honghong Han; Ping Yang; Rifang Luo; Hong Wang; Nan Huang; Wei Tan; Yajun Weng
Journal:  Colloids Surf B Biointerfaces       Date:  2016-04-26       Impact factor: 5.268

5.  Molecular design and evaluation of biodegradable polymers using a statistical approach.

Authors:  Dan Y Lewitus; Fabian Rios; Ramiro Rojas; Joachim Kohn
Journal:  J Mater Sci Mater Med       Date:  2013-07-26       Impact factor: 3.896

6.  Validation of Ultrasound Elastography Imaging for Nondestructive Characterization of Stiffer Biomaterials.

Authors:  Haoyan Zhou; Monika Goss; Christopher Hernandez; Joseph M Mansour; Agata Exner
Journal:  Ann Biomed Eng       Date:  2015-09-14       Impact factor: 3.934

7.  Impact of polymer-bound iodine on fibronectin adsorption and osteoblast cell morphology in radiopaque medical polymers: tyrosine-derived polycarbonate blends as a model system.

Authors:  Khaled A Aamer; Kirsten L Genson; Joachim Kohn; Matthew L Becker
Journal:  Biomacromolecules       Date:  2009-09-14       Impact factor: 6.988

8.  Cell patterning with mucin biopolymers.

Authors:  T Crouzier; H Jang; J Ahn; R Stocker; K Ribbeck
Journal:  Biomacromolecules       Date:  2013-08-27       Impact factor: 6.988

9.  Surface modification on polydimethylsiloxane-based microchannels with fragmented poly(l-lactic acid) nanosheets.

Authors:  Lu Yang; Yosuke Okamura; Hiroshi Kimura
Journal:  Biomicrofluidics       Date:  2015-11-20       Impact factor: 2.800

10.  Interplay of anionic charge, poly(ethylene glycol), and iodinated tyrosine incorporation within tyrosine-derived polycarbonates: Effects on vascular smooth muscle cell adhesion, proliferation, and motility.

Authors:  Patrick A Johnson; Arnold Luk; Aleksey Demtchouk; Hiral Patel; Hak-Joon Sung; Matthew D Treiser; Simon Gordonov; Larisa Sheihet; Das Bolikal; Joachim Kohn; Prabhas V Moghe
Journal:  J Biomed Mater Res A       Date:  2010-05       Impact factor: 4.396

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.