Variability of indirect methods used to determine blood pressure. Office vs mean 24-hour automated blood pressures.

P B Bottini1, A A Carr, R B Rhoades, L M Prisant.   

Abstract

Blood pressure is a cardiovascular measurement with dynamic characteristics that can be influenced by a number of internal and external factors. The preferred blood pressure determination method would be one that reduces variability between measurements and that reflects the true blood pressure level. In this article, we present the variability of, and agreement between, the blood pressures collected by two indirect methods on the same patients during a hypertensive research project. Data obtained on patients in a typical clinical setting are also provided. Twenty-four-hour diastolic pressures obtained by the automated method demonstrated no regression to a lower mean, while blood pressures obtained casually in the office exhibited such regression. The 95% confidence interval of repeated measures for casual office blood pressure on a patient in a research setting (35/17 mm Hg) or in typical clinic practice (26/19 mm Hg) were similar, while the range of the mean 24-hour automated blood pressure monitoring (21/11 mm Hg) was smaller and demonstrated less variability. The magnitudes of the differences in blood pressures obtained on separate occasions in the same subjects were significantly lower with automated vs casual blood pressure determination methods (7.9/4.6 vs 13.7/7.4 mm Hg for both systolic and diastolic pressures). The agreement (95% confidence interval) between blood pressures obtained by the two methods (19/12 mm Hg) was found to be similar to the repeatability of automated blood pressure monitoring alone, and superior to that for data recorded casually in the office (35/17 mm Hg). Thus, the variability in mean 24-hour automated blood pressures is less than that for casual office blood pressures. The clinician should understand that the variability of blood pressures measured on an individual may be much greater than that reported for populations of hypertensive patients, and must be considered when applying epidemiologic group data to a specific patient. Moreover, any methodology of indirect blood pressure measurement that may reduce the variability and improve repeatability of casual office blood pressures deserves further consideration.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1728909

Source DB:  PubMed          Journal:  Arch Intern Med        ISSN: 0003-9926


  5 in total

1.  Population pharmacokinetic-pharmacodynamic modelling of 24-h diastolic ambulatory blood pressure changes mediated by axitinib in patients with metastatic renal cell carcinoma.

Authors:  Ying Chen; Brian I Rini; Angel H Bair; Ganesh M Mugundu; Yazdi K Pithavala
Journal:  Clin Pharmacokinet       Date:  2015-04       Impact factor: 6.447

2.  Prevalence and predictors of white-coat response in patients with treated hypertension.

Authors:  M B MacDonald; G P Laing; M P Wilson; T W Wilson
Journal:  CMAJ       Date:  1999-08-10       Impact factor: 8.262

3.  Ambulatory monitoring detects sorafenib-induced blood pressure elevations on the first day of treatment.

Authors:  Michael L Maitland; Kristen E Kasza; Theodore Karrison; Kristin Moshier; Laura Sit; Henry R Black; Samir D Undevia; Walter M Stadler; William J Elliott; Mark J Ratain
Journal:  Clin Cancer Res       Date:  2009-09-22       Impact factor: 12.531

4.  Reproducibility of blood pressure response to hydrochlorothiazide.

Authors:  Javier D Finkielman; Gary L Schwartz; Arlene B Chapman; Eric Boerwinkle; Stephen T Turner
Journal:  J Clin Hypertens (Greenwich)       Date:  2002 Nov-Dec       Impact factor: 3.738

5.  Clinical efficacy of percutaneous renal revascularization with stent placement in hypertension among patients with atherosclerotic renovascular diseases.

Authors:  Seyed Mohammad Hassan Adel; Seyed Masood Syeidian; Mohammad Najafi; Mohammad Nourizadeh
Journal:  J Cardiovasc Dis Res       Date:  2011-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.