Composite depth of cure obtained with QTH and LED units assessed by microhardness and micro-Raman spectroscopy.

Glauco Botelho Santos1, Igor Studart Medeiros, Carlos Eduardo Fellows, Antonio Muench, Roberto Ruggiero Braga.   

Abstract

This study analyzed the depth of cure of a composite assessed by microhardness and the degree of conversion as a function of the light cure unit (LCU) used. Two light cure units, one LED (Ultraled-Dabi Atlante) and one quartz-tungsten-halogen (QTH, Optilux 401-Demetron) unit were used to cure 4.0 x 4.0 mm and 5.0 mm deep composite specimens (Filtek Z250, 3M ESPE). After 24 hours storage at 37 degrees C, Knoop microhardness and degree of conversion were measured on the irradiated surface and at each millimeter of the sample's depth. The degree of conversion was determined by using micro-Raman spectroscopy. The specimens cured with the QTH unit presented uniform decay in microhardness up to 4 mm in depth. Beyond 4 mm, the drop was abrupt. With LED photoactivation, uniform decay was observed only up to 2 mm. At higher depths, the decay in microhardness increased rapidly, especially beyond 3 mm. Depth of cure assessed by micro-Raman revealed that the degree of conversion behaved similarly to microhardness for both LCUs. A strong linear regression between microhardness and the degree of conversion, including both LCUs, was established with R2 = 0.980.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17288333     DOI: 10.2341/06-26

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  8 in total

1.  Mechanical properties of composite resins light-cured using a blue DPSS laser.

Authors:  Du-Man Baek; Jeong-Kil Park; Sung-Ae Son; Ching-Chang Ko; Franklin Garcia-Godoy; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2012-05-15       Impact factor: 3.161

2.  Depth of cure of bulk fill composites with monowave and polywave curing lights.

Authors:  Timothy S Menees; Chee Paul Lin; Dave D Kojic; John O Burgess; Nathaniel C Lawson
Journal:  Am J Dent       Date:  2015-12       Impact factor: 1.522

3.  Influence of curing light attenuation caused by aesthetic indirect restorative materials on resin cement polymerization.

Authors:  Bárbara Pick; Carla Castiglia Gonzaga; Washington Steagall Junior; Yoshio Kawano; Roberto Ruggiero Braga; Paulo Eduardo Capel Cardoso
Journal:  Eur J Dent       Date:  2010-07

4.  The effect of irradiation distance on microhardness of resin composites cured with different light curing units.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun
Journal:  Eur J Dent       Date:  2010-10

5.  Comparative study of surface microhardness of methacrylate-based composite resins polymerized with light-emitting diodes and halogen.

Authors:  Camila Sabatini
Journal:  Eur J Dent       Date:  2013-07

6.  Spectroscopic and Mechanical Properties of a New Generation of Bulk Fill Composites.

Authors:  Riccardo Monterubbianesi; Giovanna Orsini; Giorgio Tosi; Carla Conti; Vito Librando; Maurizio Procaccini; Angelo Putignano
Journal:  Front Physiol       Date:  2016-12-27       Impact factor: 4.566

7.  Effect of Dental Chair Light on Enamel Bonding of Orthodontic Brackets Using Light Cure Based Adhesive System: An In-Vitro Study.

Authors:  Anil Tiwari; Tarulatha Shyagali; Sarvraj Kohli; Rishi Joshi; Abhishek Gupta; Rana Tiwari
Journal:  Acta Inform Med       Date:  2016-11-01

8.  Light transmittance of zirconia as a function of thickness and microhardness of resin cements under different thicknesses of zirconia.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun; Bekir-Murat Kaya
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-03-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.