Literature DB >> 20613921

Influence of curing light attenuation caused by aesthetic indirect restorative materials on resin cement polymerization.

Bárbara Pick1, Carla Castiglia Gonzaga, Washington Steagall Junior, Yoshio Kawano, Roberto Ruggiero Braga, Paulo Eduardo Capel Cardoso.   

Abstract

OBJECTIVES: To verify the effect of interposing different indirect restorative materials on degree of conversion (DC), hardness, and flexural strength of a dual-cure resin cement.
METHODS: Discs (2 mm-thick, n=5) of four indirect restorative materials were manufactured: a layered glass-ceramic (GC); a heat-pressed lithium disilicate-based glass-ceramic veneered with the layered glass-ceramic (LD); a micro-hybrid (MH); and a micro-filled (MF) indirect composite resin. The light transmittance of these materials was determined using a double-beam spectrophotometer with an integrating sphere. Bar-shaped specimens of a dual-cure resin cement (Nexus 2/SDS Kerr), with (dual-cure mode) and without the catalyst paste (light-cure mode), were photoactivated through the discs using either a quartz-tungsten-halogen (QTH) or a light-emitting diode (LED) unit. As a control, specimens were photoactivated without the interposed discs. Specimens were stored at 37 masculineC for 24h before being submitted to FT-Raman spectrometry (n=3), Knoop microhardness (n=6) and three-point bending (n=6) tests. Data were analyzed by ANOVA/Tukey's test (alpha=0.05).
RESULTS: MH presented the highest transmittance. The DC was lower in light-cure mode than in dual-cure mode. All restorative materials reduced the cement microhardness in light-cure mode. GC and LD with QTH and GC with LED decreased the strength of the cement for both activation modes compared to the controls. Curing units did not affect DC or microhardness, except when the dual-cure cement was photoactivated through LD (LED>QTH). Flexural strength was higher with QTH compared to LED.
CONCLUSIONS: Differences in transmittance among the restorative materials significantly influenced cement DC and flexural strength, regardless of the activation mode, as well as the microhardness of the resin cement tested in light-cure mode. Microhardness was not impaired by the interposed materials when the resin cement was used in dual-cure mode.

Entities:  

Keywords:  Degree of conversion; Flexural strength; Light transmission; Microhardness; Resin cement

Year:  2010        PMID: 20613921      PMCID: PMC2897866     

Source DB:  PubMed          Journal:  Eur J Dent


INTRODUCTION

Resin cements are used for luting all-ceramic and composite indirect restorations due to their excellent mechanical properties, the possibility of their bonding to the tooth structure, and improved aesthetics compared to conventional cements.1–5 In order to maximize the clinical performance of indirect aesthetic restorations, it is crucial to observe some aspects that may affect resin cement polymerization, such as the optical behavior of the restorative material,6–8 the resin cement activation mode,9–11 and the characteristics of the light curing unit used for cement photoactivation.12,13 When visible light reaches the restorative material, part of the light is transmitted through it, part is absorbed, and part is reflected on the surface. The level of opacity of a given material depends on its internal reflectance and transmittance. Opacity is the result of high light scattering with a very low fraction of the incident beam being transmitted through the material.14 In biphasic materials, such as composites and ceramics, light scattering occurs at interfaces with different refraction indexes. In this case, the greater the difference of refraction indexes, the greater the scattering.14 The optical behavior of indirect aesthetic materials also depends on their inorganic content, matrix composition, and particle size, as well as the presence of pores incorporated during the processing of the material.14–16 The light transmittance through an indirect restorative material can greatly affect the polymerization of resin cements.17,18 In photoactivated cements, the initiation system is composed of one or more photoinitiators, such as camphorquinone (CQ) and a tertiary amine (N,N-dimethylaminoethyl methacrylate).18 In composites that contain CQ, light irradiation with wavelengths ranging between 470 and 480 nm19,20 leads CQ to a “triplet” state. In this state, CQ is capable of combining with two amine molecules, forming a photoexcitated complex (“exciplex”). After CQ removes a proton from each amine molecule, the “exciplex” breaks into free radicals that will react with the monomer carbon-carbon double bonds, initiating the polymerization reaction. If an insufficient number of CQ molecules reach the “triplet” state, the composite will not be properly cured.17,18 In dual-cure systems, a catalyst paste containing a chemical activator (benzoyl peroxide (BP)) can be mixed with the light-cured resin cement to increase free radical concentration even under insufficient light. When the two pastes are mixed together and exposed to light, free radicals are formed both by photo- and chemical-activation. It is expected that in areas where light is partially or totally attenuated, the free radicals formed by amine/BP interaction would compensate for the lack of those that result from amine/CQ interaction.11 Besides formulation7,10,21,22 and opacity23 of the indirect restorative material, other factors that interfere with the radiant exposure that reaches the cement layer are the restoration thickness7,10,21,23–26 and shade,6,24 the distance between curing unit light guide and cement layer,23 the curing protocol used,27,28 and the light curing unit.7,13,24,28,29 Light-emitting diode (LED) and quartz-tungsten-halogen (QTH) curing units can provide irradiances from 300 to 1200 mW/cm2 with the former providing a much narrower spectral emission that better matches the absorption band of CQ.30,31 The effects of irradiance, light curing time, and type of curing unit (QTH and LED) on the hardening of various resin cements have been determined.32 High-intensity light curing and longer curing times increase cement microhardness. The use of LED units resulted in resin cement microhardness similar to that achieved with conventional QTH.32 However, in direct restorative composites, the use of an LED unit promoted a lower depth of cure than QTH, which was associated with differences in light scattering due to differences in spectral emission.31 The aim of this study was to evaluate the light transmittance of indirect aesthetic restorative materials and to verify its influence on the degree of conversion (DC), Knoop microhardness, and flexural strength of a resin cement that was tested either in dual-cure or light-cure mode after its photoactivation with a QTH or an LED curing unit. The tested hypotheses were: 1) light attenuation caused by interposed indirect restorative materials impairs the evaluated properties of the resin cement in light-cure mode but not in dual-cure mode; 2) resin cement properties are influenced by differences in irradiance and spectral emission found in a QTH and an LED light unit.

MATERIALS AND METHODS

Aesthetic restorative materials

Five disc-shaped specimens (11.0 mm of diameter and 2.0±0.1 mm of thickness) of four indirect aesthetic restorative materials were prepared: a layered glass-ceramic (GC), a heat-pressed lithium disilicate-based glass-ceramic (0.8 mm of thickness) veneered with the same layered glass-ceramic (1.2 mm of thickness) (LD), a micro-hybrid (MH) and a micro-filled (MF) indirect composite (Table 1).
Table 1.

Indirect aesthetic restorative materials tested*.

GroupMaterialCompositionInorganic contentParticle size (μm)Particle by weight (%)Batch #
GCIPS Eris, Ivoclar-Vivadent, Schaan, LeichtensteinGlass-ceramic containing fluorapatita and alkali-zinc-silicateNot informedNot informedNot informedH25269
LDIPS Empress 2: veneered by IPS Eris, Ivoclar-Vivadent, Schaan, LeichtensteinIPS Empress 2: glass-ceramic reinforced by lithium disilicate IPS Eris: described aboveIPS Empress 2: lithium disilicate IPS Eris: not informedIPS Empress 2: 0.5 – 4.0 IPS Eris: not informedIPS Empress 2: 70 ± 5 IPS Eris: not informedIPS Empress 2: J06266 IPS Eris: H25269
MHSinfony, 3M ESPE, Seefeld, GermanyUDMA1-based ultra-fine particle hybrid compositeStrontium aluminium borosilicate glass; Pyrogenic silica0.5 – 0.7; 0.0640; 5253241
MFSR Adoro, Ivoclar-Vivadent, Schaan, LeichtensteinUDMA1-based microfilled compositeSilicon dioxide0.01 – 0.146 – 47H2236

Information provided by manufacturers.

Urethane dimethacrylate.

For GC, the specimens were prepared by the vibration–condensation method using a stainless steel mold (14.9 mm of diameter and 2.9 mm of thickness) and sintered in a dental porcelain furnace (Keramat I, Knebel, Porto Alegre, Brazil), following the firing schedules recommended by the manufacturer. After firing, the specimens were cut to obtain 11.0 mm diameter using a diamond bur, and the thickness of 2.0 mm was achieved using a grinding machine (MSG-600, Mitutoyo, São Paulo, Brazil). Specimens in the LD group were prepared as bi-layers. Lithium disilicate-based glass-ceramic discs were processed by the heat-press technique using a specific oven (EP 600, Ivoclar Vivadent, Schaan, Liechtenstein), following the firing schedules recommended by the manufacturer. The specimens were ground to a 0.8 mm thickness using a grinding machine. The same glass-ceramic used in the GC group was applied to one surface of the disc. The specimens were cut using a diamond bur to obtain a diameter of 11.0 mm. A final 2.0 mm thickness was achieved using a grinding machine. For MH group, a polyethylene mold was used to incrementally build the spacer to a diameter of 11.0 mm and a thickness of 2.0 mm. Each of the four increments of composite resin was photoactivated for 5 s (Visio Alfa, 3M ESPE, Seefeld, Germany). The last increment was inserted into the mold, pressed by a glass slide, and photoactivated for 40 s with the same curing unit. The disc was removed from the mold and placed into a second curing unit (Visio Beta Vario, 3M ESPE, Seefeld, Germany) for 15 min under light and vacuum. The same polyethylene mold was used for specimens in the MF group, but the composite resin was inserted into the mold in only one increment, which was pressed by a glass slide and photoactivated for 40 s (Quick curing unit, Ivoclar-Vivadent, Leichtenstein). The disc was removed from the mold and placed into a second curing unit (Targis Power Upgrade, Ivoclar-Vivadent, Leichtenstein) for 25 min under light and vacuum. All materials had the Vita A2 shade (Vita Zahnfabrik, Bad Säckingen, Germany), and both surfaces were polished using sandpaper with a sequence of decreasing grit under constant water irrigation and a felt disc with 1 μm diamond paste (Buehler, Lake Bluff, USA).

Light transmittance analysis

The total spectral transmittance of the aesthetic restorative materials, defined as the sum of the directly transmitted light and diffuse transmission by scattering,33 was determined by a double-beam spectrophotometer (Cintra 10, CBC Scientific Equipment, Dandenong, Australia) equipped with an integrating sphere, from 380 to 780 nm wave length range, at 2 nm intervals (n=5). A polished aluminum sample holder was used. For each restorative material, the total transmittance in a wavelength interval between 400 and 500 nm was calculated as the average of three measurements.

Light curing unit characterization

A quartz-tungsten-halogen curing unit (QTH, OptiluxTM 501, SDS Kerr, Orange, USA) and a light-emitting diode (LED, L.E.Demetron 1, SDS Kerr, Orange USA) were selected for use in this study, and their spectral emission and irradiance were determined by a spectroradiometer (Photo Research, model PR-705, series 75033201, Chatsworth, USA) with an integrating sphere (Optronic, model OL IS-670, series 96100046, Orlando, USA). Three measurements were performed in a wavelength range between 380 and 780 nm, at 2 nm intervals.

Specimen preparation

Bar-shaped specimens (10 mm length x 2 mm width x 1 mm height) were prepared in a metallic mold using only the light-curable paste of the dual-cure resin cement (light-cure mode, Table 2) or the dual-curable paste mixture of the same resin cement (i.e., with catalyst paste, dual-cure mode, Table 2). For the dual-cure mode, base and catalyst pastes were weighted equally on an analytical balance, with 0.0001 g accuracy (Adventure, Ohaus, China). For both light-cure and dual-cure modes, specimens were photoactivated between two polyester strips and through the indirect restorative materials discs. To guarantee the correct position of the restorative material disc, curing unit tip and resin cement specimen, a black polyacetal device was used (Figure 1). As a control, light-cure and dual-cure specimens were photoactivated without any interposed restorative material, with the curing unit light guide placed at a 2 mm distance from the cement surface. Half of the specimens were photoactivated with the QTH (Optilux™ 501, SDS Kerr, Orange, USA) and the other half with the LED (L. E. Demetron 1, SDS Kerr, Orange, USA), both for 60 s, as the minimum recommended by the resin cement manufacturer is 40 s. After photoactivation, each specimen had the irradiated surface identified and its dimensions were checked using a digital caliper (Starrett, Itu, Brazil). The specimens were stored in the dark with distilled water at 37ºC for 24 h.
Table 2.

Resin cement tested*.

MaterialManufacturerCompositionInorganic contentParticle size (μm)Particle by weight (%)Batch #
Nexus 2 base paste (clear shade)SDS Kerr, Orange, USABis-GMA1; TEGDMA2Silicon dioxide0.647436600
Nexus 2 catalyst paste (low viscosity)SDS Kerr, Orange, USABis-GMA1, TEGDMA2, benzoyl peroxideNot informedNot informedNot informed432687

Information provided by manufacturers.

A-diglycidyl-dimetacrylate.

Triethylene glycol dimethacrylate.

Figure 1.

Set-up for the resin cement specimen preparation.

Degree of conversion

Three specimens from each experimental group were used for DC evaluation. All specimens’ surfaces were polished in a semi-automatic polisher (Twin Variable Speed Grinder Polisher EcoMet and Power Head AutoMet 2000, Buehler, Lake Bluff, USA), under constant water irrigation, using a 4000 grit sandpaper for 2 min. An FT-Raman spectrometer equipped with a 100 mW, 1064 nm Nd:YAG laser source (model RFS 100/S, Bruker Optics, Billerica, USA) was used to obtain spectra in the 1000 to 2000 cm−1 interval by co-addition of 64 scans at a spectral resolution of 4 cm−1. DC of each specimen was the average of four measurements, two performed at the irradiated and two at the non-irradiated surface. The ratio (R) between aliphatic (1640 cm−1) and aromatic (1610 cm−1) carbon double bond bands was used to calculate the DC, according to the formula:34

Knoop microhardness

Knoop microhardness (n=6) was determined on the lateral surface of the specimens. The surfaces were polished as described above for the DC specimens. Knoop microhardness of each specimen was calculated as the average of the six indentations made using a microhardness tester (Shimadzu, model HMV – 2T, Kyoto, Japan) with a load of 100 g and a dwell time of 15 s.35

Flexural strength

Flexural strength (n=6) was obtained using a three-point bending test in a universal test machine (Kratos, Cotia, SP, Brazil) with a crosshead speed of 0.5 mm/min. The flexural strength (σ=), in MPa, was calculated using the following equation:11,36 where P is the maximum load at the point of fracture (N), L the span length (6 mm), w the width of the sample, and h its height.

Statistical analysis

Transmittance data was analyzed by one-way analysis of variance (ANOVA). DC, Knoop microhardness, and flexural strength data were submitted to three-way ANOVA with curing unit, resin cement activation mode, and restorative materials as independent variables. Tukey’s test was used for multiple comparisons. Tests were performed with a pre-set global significance of 5%.

RESULTS

Total transmittance analysis and light curing unit characterization

Figure 2 shows the transmittance spectra of the aesthetic restorative materials. For all materials, transmittance increased at higher wavelengths. Light transmittance in the 400 to 500 nm range was higher for MH (3.50±0.31%a, P<.001), followed by MF (2.15±0.22%b), LD (1.93±0.23%bc), and GC (1.63±0.21%c).
Figure 2.

Total transmittance spectra of the aesthetic restorative materials evaluated. The spectrum of each material was obtained based on the mean values at 2 nm wavelength intervals.

Figure 3 shows the emission spectra of the QTH and LED units. The maximum irradiance of QTH was situated at 492 nm, while for the LED it was at 452 nm. Total irradiances were 750 mW/cm2 for QTH and 1060 mW/cm2 for LED.
Figure 3.

Spectral emission of the quartz-tungsten-halogen curing unit (QTH, OptiluxTM 501/SDS Kerr, USA) and the light-emitting diode (LED, L. E. Demetron 1, SDS Kerr, USA) tested. The vertical dotted lines correspond to the camphorquinone absorbance range.

Table 3 shows the DC means and standard deviations as a function of curing unit, cement activation mode, and restorative material. None of the interactions was statistically significant (P>.05). Moreover, DC was not significantly affected by the curing unit (P=0.698). Dual-cured specimens presented higher DC than light-cured (74.1±3.3% and 64.9±4.5%, respectively, P<.001). Regarding the restorative materials, there was no statistical difference among the control (72.7±4.0%a), MH (70.1±4.9%ab) and MF (68.9±6.7%ab, P<.01). However, GC (67.4±6.8%b) and LD (68.2±6.9%b) presented lower DC than the control.
Table 3.

Mean and standard deviation of degree of conversion, Knoop microhardness and flexural strength values as a function of curing unit, cement activation mode and restorative material interaction. Columns with same letters indicate absence of statistical difference (P>.05)

Curing unitRestorative materialDegree of conversion (%)Knoop microhardness (KHN)Flexural strength (MPa)
Light-cureDual-cureLight-cureDual-cureLight-cureDual-cure
QTHControl70.2±1.8abc76.0±2.2a43.9±1.0AB43.8±0.5AB218±29b247±23a
GC61.1±2.9c75.0±1.2ab19.3±4.6H40.3±1.0BC110±19fg182±11bcd
LD61.9±1.5c71.4±8.5abc23.4±2.3GH32.1±4.4DEF158±32cdef212±32b
MH67.3±3.1abc73.7±2.9ab34.3±1.6DE41.8±2.8ABC166±24bcde240±14a
MF64.7±0.1bc75.3±1.0ab29.3±2.1EF48.2±1.0A187±12bcd224±9ab

LEDControl69.6±5.1abc74.9±2.6ab44.2±1.5AB44.9±0.9AB177±30bcde218±35b
GC61.7±2.5c71.9±4.1abc22.2±1.6GH39.8±1.5BC75±12g139±30de
LD65.3±6.1abc74.3±2.4ab27.0±5.8FG43.8±0.4AB129±29e187±26bcd
MH65.2±4.7abc74.3±1.1ab37.0±2.6CD43.9±1.8AB177±11bcde211±17b
MF61.5±4.4c74.2±3.5ab31.5±2.1EF45.9±2.1A132±22e204±14bc
Table 3 shows Knoop microhardness means and standard deviations as a function of curing unit, resin cement activation mode, and restorative material interaction. The triple-order interaction was statistically significant (P<.001). The control groups were not affected by any curing unit/resin cement activation mode combinations. Dual-cure mode specimens presented higher Knoop microhardness than light-cure for all curing unit/restorative material combinations. In general, hardness values obtained by the dual-cured cement were similar to the control, except for LD-QTH. When the cement was light-cured, none of the restorative material/curing unit combinations reached hardness similar to the control. The curing units did not influence the Knoop microhardness values of the light-cured cement. The Knoop microhardness values for the dual-cured cement were not affected by the curing unit, except for LD (LED>QTH). The statistical analysis for the flexural strength test detected significant differences only for the main factors (P<.001). Table 3 shows the flexural strength means and standard deviations as a function of curing unit, cement activation mode, and restorative material interaction. When tested in dual-cure mode, the flexural strength mean was higher than in the light-cure mode (199.4±36.5 MPa and 152.9±45.3 MPa, respectively, P<.001). Furthermore, the use of the QTH resulted in higher strength than the LED unit (194.5±45.2 MPa and 164.9±48.4 MPa, respectively, P<.001). Regarding the restorative materials, MH (198.7±33.8 MPaab) allowed a flexural strength similar to the control (215.0±37.5 MPaa). There was no statistical difference between MH and MF (186.7±37.6 MPabc) or between the latter and LD (171.2±42.2 MPac). Specimens photoactivated through GC (126.8±44.0 MPad) showed the lowest flexural strength value for the resin cement (P<.001).

DISCUSSION

The first hypothesis of this study, which stated that the light attenuation caused by the indirect restorative materials impairs the evaluated properties of the resin cement in light-cure mode but not in dual-cure mode, was partially proven. For DC, in spite of the fact that the light-cure mode showed lower values than the dual-cure mode, the interaction between the cement activation mode and the restorative material was not statistically significant. Therefore, it is not possible to affirm that the attenuation caused by the restorative materials was the sole factor responsible for the lower DC of the resin cement in light-cure mode. On the other hand, the attenuation caused by all the restorative materials reduced cement microhardness in light-cure mode, while the self-cure activator present in the dual-cure mode helped to keep KHN similar to the control, except in the LD/QTH group. Finally, light attenuation caused a reduction of the cement flexural strength for both activation modes for three specific material/light unit combinations (namely, GC/QTH, LD/QTH, and GC/LED). Many studies comparing both activation modes showed that the chemical activation in combination with photoactivation guarantees better properties in the resin cement.11,19,28,37–40 The amount of light reflected, absorbed, and transmitted depends on the number and size of particles and pores within the matrix.41 MH presented the highest transmittance, while no statistical differences were found between MF and LD and between LD and GC. The statistical difference in transmittance between MH and MF may be related to their filler size. With smaller particle sizes, more interfaces are present and, consequently, more scattering will occur, increasing the composite opacity in the wavelength range studied.15 Previous studies concerning the relationship between light scattering and composite particle size indicated that bigger fillers allowed deeper composite resin polymerization,42 which corresponds with the fact that the MH composite, which has larger particles than MF resin, transmitted more light. Considering the statistically significant data, differences in transmittance among the restorative materials were reflected in DC and flexural strength results, irrespective of the resin cement activation mode, as well as in Knoop microhardness of the resin cement specimens tested in light-cure mode. The higher the material’s transmittance, the higher the irradiance reaching the cement surface, which increased its DC and mechanical properties. Indeed, both MH and MF allowed the resin cement to reach a DC similar to the control. In addition, with one exception, Knoop microhardness was higher when the resin cement in light-cure mode was photoactivated through the composite resins rather than the ceramics. Similar findings were reported in a previous study.40 However, other studies disagree with the present results, showing that cement DC and microhardness were lower when photoactivated through a composite compared to porcelain spacers.10,37 Such inconsistencies can be explained by the different refraction indexes and surface roughness between composite and ceramic, which are consequences of their distinct natures.40 The incident intensity is the sum of the transmitted, absorbed, and reflected light.14 Therefore, differences in the surface finishing in the composite and ceramic and the presence of molecules that absorb radiation in the surface layer in the ceramics contributed to an increase in the reflectance and/or absorbance and, consequently, decreased the transmittance of the ceramics.43 The second hypothesis of this study, which stated that the resin cement properties are influenced by differences in irradiance and spectral emission between the LED and QTH unit, was partially confirmed. Though LED spectral emission was more concentrated between 425 and 490 nm and presented higher irradiance than QTH, no statistically significant differences in DC and Knoop microhardness were verified between LED and QTH, except for the hardness of the dual-cured cement specimens photoactivated through LD (LED>QTH). A previous study reported that the use of high irradiances resulted in consistently higher mechanical properties of resin-based materials.32 However, when the irradiance exceeds 600 mW/cm2, as occurred in the present study, the differences between units was not significant.24,32 Regarding the flexural strength, the use of QTH resulted in 15% higher strength than the LED. However, considering the non-significant third-order interaction, strength was higher with QTH than with LED only with MF in light-cure mode and with the control and the MH groups in dual-cure mode. The lower irradiance of QTH probably was offset by the higher wavelength range. We observed that the light transmittance through restorative materials increased with the increase of wavelength. This is in accordance with the Rayleigh scattering equation, which states that the higher the wavelengths, the lower the light scattering.33,44 Thus, the higher the wavelength emitted by the curing light, the higher the transmittance. The fact that the influence of the curing unit was observed only in flexural strength may be explained by the fact that this property is more influenced by the DC reached at the non-irradiated surface of the specimen. As specimen failure initiates at the bottom surface of the specimen and all specimens were positioned with the irradiated surface toward the load application, a lower DC at the non-irradiated surface of the specimen would lead to a reduced flexural strength. This reduced level of DC was not shown in KHN results because they are the average of six indentations performed on the lateral surface of the specimen. In fact, a previous study that compared QTH and LED found that at deep regions of the composite specimen, due to the high light scattering promoted by the filling as a consequence of low wavelengths, LED irradiance drops more severely than irradiance of QTH.31 It is known that a reduction in light irradiance can be counterbalanced by increasing the exposure time of the composite to the light source.45 It was reported that the resin cement, in both activation modes, cured through porcelain or cast glass ceramic specimens with a thickness of 1.0 mm or less was thoroughly polymerized with a 60-second exposure time.46 Another study showed that a 60 s exposure time did not provide adequate polymerization of the resin cements in light-cure mode through porcelain discs with 0.75 mm thickness; however, when the catalyst was used, exposure times longer than 60 s did not provide any significant changes in hardness.39 Based on that finding, the exposure time used in the present study was 60 s, above the 40 s recommended by the cement manufacturer. Further investigation is necessary with different restorative materials, resin cements, and curing units, using other mechanical tests or even adhesion tests to confirm the results. Due to the resin cement thickness and the absence of aging mechanisms, the results of the present study cannot predict or summarize the performance and longevity of an aesthetic indirect restoration. Among the restorative materials evaluated, the micro-hybrid composite presented the highest transmittance. The resin cement in light-cure mode showed lower DC than in dual-cure mode. However, it was not possible to affirm that the attenuation caused by the restorative materials was responsible for this occurrence. When the resin cement was tested in light-cure mode, the light attenuation caused by the restorative materials negatively affected its microhardness. The light attenuation caused just by GC and LD with QTH and GC with LED decreased the flexural strength of the cement in both activation modes. Though LED spectral emission was closer to the camphorquinone absorbance range and presented higher irradiance than QTH, no statistically significant differences in DC and Knoop microhardness were verified, except for LD/LED in dual-cure mode.
  44 in total

1.  LED and halogen lights: effect of ceramic thickness and shade on curing luting resin.

Authors:  Nasser Barghi; Elizabeth H McAlister
Journal:  Compend Contin Educ Dent       Date:  2003-07

2.  A study of the physical and chemical properties of four resin composite luting cements.

Authors:  Ovul Kumbuloglu; Lippo V J Lassila; Atilla User; Pekka K Vallittu
Journal:  Int J Prosthodont       Date:  2004 May-Jun       Impact factor: 1.681

3.  The effect of specimen dimensions on the flexural strength of a composite resin.

Authors:  Antonio Muench; Ivo Carlos Correa; Rosa Helena Miranda Grande; Mário João
Journal:  J Appl Oral Sci       Date:  2005-09       Impact factor: 2.698

4.  Influence of ceramic thickness and polymerization mode of a resin luting agent on early bond strength and durability with a lithium disilicate-based ceramic system.

Authors:  Gokhan Akgungor; Begum Akkayan; Hubert Gaucher
Journal:  J Prosthet Dent       Date:  2005-09       Impact factor: 3.426

5.  Curing units' ability to cure restorative composites and dual-cured composite cements under composite overlay.

Authors:  Sung-Ho Park; Su-Sun Kim; Yong-Sik Cho; Chang-Kyu Lee; Byng-Duk Noh
Journal:  Oper Dent       Date:  2004 Nov-Dec       Impact factor: 2.440

6.  Curing efficiency of a photo- and dual-cured resin cement polymerized through 2 ceramics and a resin composite.

Authors:  Efstratios Papazoglou; Chris Rahiotis; Afrodite Kakaboura; Michael Loukidis
Journal:  Int J Prosthodont       Date:  2006 Jan-Feb       Impact factor: 1.681

7.  Variables affecting the spectral transmittance of light through porcelain veneer samples.

Authors:  K L O'Keefe; P L Pease; H K Herrin
Journal:  J Prosthet Dent       Date:  1991-10       Impact factor: 3.426

8.  Analysis of optical transmission by 400-500 nm visible light into aesthetic dental biomaterials.

Authors:  D C Watts; A J Cash
Journal:  J Dent       Date:  1994-04       Impact factor: 4.379

9.  The attenuation of radiation by porcelain and its effect on polymerization of resin cements.

Authors:  S Uctasli; U Hasanreisoglu; H J Wilson
Journal:  J Oral Rehabil       Date:  1994-09       Impact factor: 3.837

10.  UV-Vis spectrophotometric analysis and light irradiance through hot-pressed and hot-pressed-veneered glass ceramics.

Authors:  Myrna Carvalho Dias; Evandro Piva; Rafael Ratto de Moraes; Gláucia Maria Bovi Ambrosano; Mário Alexandre Coelho Sinhoreti; Lourenço Correr-Sobrinho
Journal:  Braz Dent J       Date:  2008
View more
  6 in total

1.  How the translucency of direct anatomic fiber posts affects the bond strength and microhardness of a self-adhesive luting agent in flared roots.

Authors:  Camilo Pulido; Osnara Mongruel Gomes; Alessandro Dourado Loguercio; Andrés Dávila-Sánchez; Fernando Camilotti; Gerson Kniphoff da Cruz; Cesar Augusto Galvão Arrais
Journal:  Clin Oral Investig       Date:  2022-02-15       Impact factor: 3.573

2.  An in vitro study to compare the influence of different all-ceramic systems on the polymerization of dual-cure resin cement.

Authors:  Anindita Majumder; T K Giri; S Mukherjee
Journal:  J Indian Prosthodont Soc       Date:  2019 Jan-Mar

Review 3.  Correlation between clinical performance and degree of conversion of resin cements: a literature review.

Authors:  Grace De Souza; Roberto Ruggiero Braga; Paulo Francisco Cesar; Guilherme Carpena Lopes
Journal:  J Appl Oral Sci       Date:  2015 Jul-Aug       Impact factor: 2.698

4.  Curing efficiency of dual-cure resin cement under zirconia with two different light curing units.

Authors:  Pınar Gultekin; Elif Pak Tunc; Deger Ongul; Volkan Turp; Ozgur Bultan; Burcin Karataslı
Journal:  J Istanb Univ Fac Dent       Date:  2015-04-29

5.  Ceramic veneers with minimum preparation.

Authors:  Leonardo Fernandes da Cunha; Rachelle Reis; Lino Santana; Jose Carlos Romanini; Ricardo Marins Carvalho; Adilson Yoshio Furuse
Journal:  Eur J Dent       Date:  2013-10

6.  Transmission of Curing Light through Moist, Air-Dried, and EDTA Treated Dentine and Enamel.

Authors:  E Uusitalo; J Varrela; L Lassila; P K Vallittu
Journal:  Biomed Res Int       Date:  2016-06-30       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.