Literature DB >> 17285280

One-molar gadolinium chelate (gadobutrol) as a contrast agent for CT angiography of the thoracic and abdominal aorta.

José M Esteban1, Antonio Alonso, Vicente Cervera, Vicente Martínez.   

Abstract

The aim of our study was to evaluate the use of a 1-molar gadolinium chelate (gadobutrol) as an alternative contrast medium for computed tomography angiography (CTA) exams of the aorta. CTA exams of the thoracic and/or abdominal aorta were performed on 15 patients with contraindications for the use of iodine who were not suitable for magnetic resonance examinations. The exams were performed with a 16-detector row scanner, injecting a mean dose of 0.37 mmol Gd/kg of body weight at a flow rate of 4 ml/s. Creatinine levels were obtained prior to the exam in patients with impaired renal function, and 24 and 48 h afterwards. The mean attenuation values obtained in the middle ascending and middle descending thoracic aorta were 202.3 and 216.8, respectively. The mean HU values of the abdominal aorta were 210.4 at the level of the renal arteries and 186.8 in the aortic bifurcation. All the exams were considered diagnostically adequate. No significant increase in serum creatinine was observed 24 and 48 h after the exam. We believe that gadobutrol could be an alternative contrast medium for CTA exams with 16-detector row scanners in patients with contraindications for iodinated contrast medium.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17285280     DOI: 10.1007/s00330-007-0590-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  39 in total

1.  Aortoiliac gadolinium-enhanced CT angiography: improved results with a 16-detector row scanner compared with a four-detector row scanner.

Authors:  Stephan Wicky; Alan Greenfield; Chieh-Min Fan; Stuart C Geller; Leena M Hamberg; Udo Hoffmann; Arthur C Waltman
Journal:  J Vasc Interv Radiol       Date:  2004-09       Impact factor: 3.464

2.  Acute renal failure after arteriography with a gadolinium-based contrast agent.

Authors:  J Gemery; B Idelson; S Reid; E K Yucel; H Pagan-Marin; S Ali; L Casserly
Journal:  AJR Am J Roentgenol       Date:  1998-11       Impact factor: 3.959

3.  Gadolinium-enhanced multidetector CT angiography of the thoracoabdominal aorta.

Authors:  Musturay Karcaaltincaba; W Dennis Foley
Journal:  J Comput Assist Tomogr       Date:  2002 Nov-Dec       Impact factor: 1.826

4.  Gadolinium as a CT contrast agent: assessment in a porcine model.

Authors:  D S Gierada; K T Bae
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

5.  Attenuation characteristics and application of gadolinium-DTPA in fast helical computed tomography.

Authors:  W Luboldt; M De Santis; A von Smekal; M Reiser
Journal:  Invest Radiol       Date:  1997-11       Impact factor: 6.016

Review 6.  Value of 1.0- M gadolinium chelates: review of preclinical and clinical data on gadobutrol.

Authors:  Bernd Tombach; Walter Heindel
Journal:  Eur Radiol       Date:  2002-02-21       Impact factor: 5.315

Review 7.  Tolerance data of Gd-DTPA: a review.

Authors:  H P Niendorf; J C Dinger; J Haustein; I Cornelius; A Alhassan; W Clauss
Journal:  Eur J Radiol       Date:  1991 Jul-Aug       Impact factor: 3.528

8.  Gadolinium-enhanced CT angiography of the circle of Willis and neck.

Authors:  John W Henson; Raul G Nogueira; Diego J Covarrubias; R Gilberto Gonzalez; Michael H Lev
Journal:  AJNR Am J Neuroradiol       Date:  2004 Jun-Jul       Impact factor: 3.825

Review 9.  Contrast media and the kidney: European Society of Urogenital Radiology (ESUR) guidelines.

Authors:  H S Thomsen; S K Morcos
Journal:  Br J Radiol       Date:  2003-08       Impact factor: 3.039

10.  Safety of gadolinium contrast angiography in patients with chronic renal insufficiency.

Authors:  Albert D Sam; Mark D Morasch; Jeremy Collins; Gina Song; Richard Chen; F Scott Pereles
Journal:  J Vasc Surg       Date:  2003-08       Impact factor: 4.268

View more
  6 in total

1.  CT Image Contrast of High-Z Elements: Phantom Imaging Studies and Clinical Implications.

Authors:  Paul F FitzGerald; Robert E Colborn; Peter M Edic; Jack W Lambert; Andrew S Torres; Peter J Bonitatibus; Benjamin M Yeh
Journal:  Radiology       Date:  2015-09-10       Impact factor: 11.105

2.  Iodine contrast media doses equal-attenuating with gadolinium chelates at CT-aortography may have less risk of contrast-induced nephropathy and no risk of nephrogenic systemic fibrosis in azotaemic patients!

Authors:  Ulf Nyman; Barbara Elmståhl; Peter Leander; Torsten Almén
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

3.  Iodine contrast iso-attenuating with diagnostic gadolinium doses in CTA and angiography results in ultra-low iodine doses. A way to avoid both CIN and NSF in azotemic patients?

Authors:  Ulf Nyman; Barbara Elmståhl; Håkan Geijer; Peter Leander; Torsten Almén; Mats Nilsson
Journal:  Eur Radiol       Date:  2010-08-29       Impact factor: 5.315

4.  Gadolinium Enhances Dual-energy Computed Tomography Scan of Pulmonary Artery.

Authors:  An Xie; Wen-Jie Sun; Yan-Feng Zeng; Peng Liu; Jian-Bin Liu; Feng Huang
Journal:  Curr Med Sci       Date:  2022-09-30

5.  Complementary contrast media for metal artifact reduction in dual-energy computed tomography.

Authors:  Jack W Lambert; Peter M Edic; Paul F FitzGerald; Andrew S Torres; Benjamin M Yeh
Journal:  J Med Imaging (Bellingham)       Date:  2015-09-21

6.  Feasibility and accuracy of dual-layer spectral detector computed tomography for quantification of gadolinium: a phantom study.

Authors:  Robbert W van Hamersvelt; Martin J Willemink; Pim A de Jong; Julien Milles; Alain Vlassenbroek; Arnold M R Schilham; Tim Leiner
Journal:  Eur Radiol       Date:  2017-01-25       Impact factor: 5.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.