Literature DB >> 17282583

Reduction of Beam-Hardening Artifacts in X-Ray CT.

Nathalie Menvielle1, Yves Goussard, Dominique Orban, Gilles Soulez.   

Abstract

Our goal is to decrease the importance of beam- hardening artifacts in X-ray computed tomography by address- ing the polyenergetic nature of the X-ray source. We use the same physical model as De Man and al [1]. We next adopt an estimation framework for the reconstruction: the attenuation coefficients are determined by a likelihood-based estimator. This approach leads to minimization of an objective function which exhibits a complex structure. Nonetheless, we develop a numerical procedure with satisfactory numerical efficiency : we use a nonlinear conjugate gradient method. The three major contributions of this communication are : the positivity of the solution ensured by a change of variables, the convergence properties of the algorithm, and a satisfying computation time.

Entities:  

Year:  2005        PMID: 17282583     DOI: 10.1109/IEMBS.2005.1616814

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  5 in total

1.  Novel technique for addressing streak artifact in gated dual-source MDCT angiography utilizing ECG-editing.

Authors:  Laura T Meyer; Daniel T Boll
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

2.  Non-convexly constrained image reconstruction from nonlinear tomographic X-ray measurements.

Authors:  Thomas Blumensath; Richard Boardman
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2015-06-13       Impact factor: 4.226

3.  Dual energy computed tomography quantification of carotid plaques calcification: comparison between monochromatic and polychromatic energies with pathology correlation.

Authors:  Lorenzo Mannelli; Lawrence MacDonald; Marcello Mancini; Marina Ferguson; William P Shuman; Monica Ragucci; Serena Monti; Dongxiang Xu; Chun Yuan; Lee M Mitsumori
Journal:  Eur Radiol       Date:  2014-12-24       Impact factor: 5.315

4.  Changes in measured size of atherosclerotic plaque calcifications in dual-energy CT of ex vivo carotid endarterectomy specimens: effect of monochromatic keV image reconstructions.

Authors:  Lorenzo Mannelli; Lee M Mitsumori; Marina Ferguson; Dongxiang Xu; Baocheng Chu; Kelley R Branch; William P Shuman; Chun Yuan
Journal:  Eur Radiol       Date:  2012-08-21       Impact factor: 5.315

5.  Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom.

Authors:  Hyo-Jin Kang; Jeong Min Lee; Sang Min Lee; Hyun Kyung Yang; Ri Hyeon Kim; Ju Gang Nam; Aruna Karnawat; Joon Koo Han
Journal:  BMC Med Imaging       Date:  2019-08-28       Impact factor: 1.930

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.