Literature DB >> 17278973

Small artery elasticity assessed by pulse wave analysis is no measure of endothelial dysfunction.

Timm H Westhoff1, Sven Schmidt, Katja Vallbracht-Israng, Havva Yildirim, Nadine Franke, Fernando Dimeo, Walter Zidek, Markus van der Giet.   

Abstract

OBJECTIVES: Determination of endothelial function has emerged as a crucial factor in the assessment of individual cardiovascular risk. Sonographic measurement of flow-mediated dilation (FMD) is the most widespread technique to assess endothelial function, but analysis is very time-consuming and requires an experienced examiner. Recently, it was speculated that a reduction of small artery compliance (C2) measured by pulse wave analysis might be an indicator of endothelial dysfunction. In the present study, we investigated the correlation of pulse wave analysis parameters and endothelial function with special regard to patients who are at increased risk for endothelial dysfunction.
METHODS: One hundred and thirty-six subjects (65 male, 71 female) were included in the study. One hundred and twenty-three probands were hypertensive. Endothelium-dependent vasodilation was assessed sonographically (flow-mediated dilation) using standard protocols and as a change of reflection index (deltaRI) after application of salbutamol by photoplethysmography. Small artery compliance, large artery compliance (C1), and systemic vascular resistance (SVR) were measured by computerized pulse wave analysis of the radial artery (CR-2000; Hypertension Diagnostics, Eagan, Minnesota, USA) and were tested for correlation with FMD.
RESULTS: Mean FMD was 6.29 +/- 2.86%. Means of pulse wave analysis-derived vascular parameters were 4.91 +/- 2.86 ml/mmHg x 100 (C2), 13.35 +/- 5.41 ml/mmHg x 10 (C1) and 1611.6 +/- 348.5 dynes x s x cm(-5) (SVR). Regression analysis excluded a significant correlation between FMD, C2, C1 and SVR (r2 < 0.05 each) both in hypertensives and normotensives. There was no significant correlation between C2 and deltaRI (r2 = 0.023).
CONCLUSION: Our findings show that static measurement of vascular parameters by an automated pulse-wave analysis procedure cannot be used to assess endothelial function. Further studies are needed to examine whether a dynamic measurement of arterial compliance before and after stimulation of the endothelium (e.g. by ischemia) might quantify endothelial dilatory capacity in a better way.

Entities:  

Mesh:

Year:  2007        PMID: 17278973     DOI: 10.1097/HJH.0b013e3280148301

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  3 in total

1.  The effects of functional electrical stimulation leg cycle ergometry training on arterial compliance in individuals with spinal cord injury.

Authors:  D Zbogar; J J Eng; A V Krassioukov; J M Scott; B T A Esch; D E R Warburton
Journal:  Spinal Cord       Date:  2008-04-15       Impact factor: 2.772

2.  A combined measure of vascular risk for white matter lesions.

Authors:  Amber Watts; Robyn A Honea; Sandra A Billinger; Kathleen T Rhyner; Lewis Hutfles; Eric D Vidoni; Jeffrey M Burns
Journal:  J Alzheimers Dis       Date:  2015       Impact factor: 4.472

3.  Long-term exposure to airborne particles and arterial stiffness: the Multi-Ethnic Study of Atherosclerosis (MESA).

Authors:  Marie S O'Neill; Ana V Diez-Roux; Amy H Auchincloss; Mingwu Shen; João A Lima; Joseph F Polak; R Graham Barr; Joel Kaufman; David R Jacobs
Journal:  Environ Health Perspect       Date:  2011-01-18       Impact factor: 9.031

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.