Literature DB >> 17278820

Monte Carlo and experimental dosimetry of an 1251 brachytherapy seed.

James Dolan1, Zuofeng Lia, Jeffrey F Williamson.   

Abstract

We have performed a comprehensive dosimetric characterization of the Oncura model 6711 125I seed using both experimental [LiF thermoluminscent dosimetry (TLD)] and theoretical (Monte Carlo photon transport) methods. In addition to determining the dosimetric parameters of the 6711, this report quantified: (1) the angular dependence of LiF TLD energy response functions for both point and volume detectors in water, poly(methylmethacrylate), and solid water media; and (2) the contribution of underlying geometric uncertainties to the overall uncertainty of Monte Carlo derived dosimetric parameters according to the National Institute of Standards and Technology Report 1297 methodology. The theoretical value for the dose rate constant in water was 0.942 cGy U(-1) h(-1)+/-1.76% [combined standard uncertainty (CSU) with coverage factor k=1] and the experimental value was 0.971 cGy U(-1) h(-1)+/-6.1%. Agreement between experimental and theoretical radial dose function values was well within the k= 1 CSU, while agreement between experimental and theoretical anisotropy function values was within the k= 1 CSU only after incorporating the use of polar angle-dependent energy response functions. The angular dependence of the relative energy response was found to have a complex and significant dependence on measurement medium and internal geometry of the source.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17278820     DOI: 10.1118/1.2388158

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  A Monte Carlo study of I-125 prostate brachytherapy with gold nanoparticles: dose enhancement with simultaneous rectal dose sparing via radiation shielding.

Authors:  D Brivio; P L Nguyen; E Sajo; W Ngwa; P Zygmanski
Journal:  Phys Med Biol       Date:  2017-01-31       Impact factor: 3.609

2.  Comparison of dose calculation methods for brachytherapy of intraocular tumors.

Authors:  Mark J Rivard; Sou-Tung Chiu-Tsao; Paul T Finger; Ali S Meigooni; Christopher S Melhus; Firas Mourtada; Mary E Napolitano; D W O Rogers; Rowan M Thomson; Ravinder Nath
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  On the feasibility of polyurethane based 3D dosimeters with optical CT for dosimetric verification of low energy photon brachytherapy seeds.

Authors:  Justus Adamson; Yun Yang; Titania Juang; Kelsey Chisholm; Leith Rankine; John Adamovics; Fang Fang Yin; Mark Oldham
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

4.  Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

Authors:  Regina K Fulkerson; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

5.  Dosimetric effect of tissue heterogeneity for (125)I prostate implants.

Authors:  Susana Maria Oliveira; Nuno José Teixeira; Lisete Fernandes; Pedro Teles; Pedro Vaz
Journal:  Rep Pract Oncol Radiother       Date:  2014-04-16

6.  An EGSnrc investigation of the air-kerma strength, dose rate constant, and radial dose function of 125I brachytherapy sources.

Authors:  Sridhar Sahoo; T Palani Selvam
Journal:  Radiol Phys Technol       Date:  2009-07-11

7.  Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique.

Authors:  Andrew Sampson; Yi Le; Jeffrey F Williamson
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

8.  Dosimetric Evaluation and Clinical Application of Radioactive Iodine-125 Brachytherapy Stent in the Treatment of Malignant Esophageal Obstruction.

Authors:  Zhe Ji; Qianqian Yuan; Lei Lin; Chao Xing; Xusheng Zhang; Sen Yang; Yuliang Jiang; Haitao Sun; Kaixian Zhang; Junjie Wang
Journal:  Front Oncol       Date:  2022-03-24       Impact factor: 6.244

9.  New (125)I brachytherapy source IsoSeed I25.S17plus: Monte Carlo dosimetry simulation and comparison to sources of similar design.

Authors:  Evaggelos Pantelis; Panagiotis Papagiannis; Giorgos Anagnostopoulos; Dimos Baltas
Journal:  J Contemp Brachytherapy       Date:  2013-12-21

10.  Measurement of the strength of iodine-125 seed moving at unknown speed during implantation in brachytherapy.

Authors:  Kenichi Tanaka; Satoru Endo; Kunihiko Tateoka; Osamu Asanuma; Ken-Ichi Kamo; Kaori Sato; Hiromitsu Takeda; Masaru Takagi; Masato Hareyama; Jun Takada
Journal:  J Radiat Res       Date:  2013-06-30       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.