Characterization of a novel heart and respiratory rate sensor.

J Jacobs1, P Embree, M Glei, S Christensen, P Sullivan.   

Abstract

Existing methods of electronic patient monitoring require tethering the patient to the device, which is not well tolerated. This study characterizes the performance of a novel sensor array and digital signal processing (DSP) algorithms that extract heart and respiratory rates. The sensor lies under the sheets on a hospital bed, and when the patient lies down, it detects pressure waves generated by the heart, and by the act of breathing. The algorithms identify these signals of interest, filtering out extraneous signals. Output of the algorithms was compared to output from ECG and transthoracic impedance, taken from the same subject, at the same time. Forty-four adult volunteers were recruited. The results demonstrated an average of mean differences for heart rate of 0.50 beats per minute, with a standard deviation of 0.51. The average of mean differences for respiratory rate was 0.39 with standard deviation of 0.55. These results suggest this noninvasive, non-restrictive method of measuring heart and respiratory rates may be a viable solution to the problem of decreased vigilance of patient condition faced on the in-patient wards. Future studies will characterize performance in ill populations, and examine alarm schemes that are both highly sensitive and specific for the target population.

Entities:  

Year:  2004        PMID: 17272168     DOI: 10.1109/IEMBS.2004.1403648

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  4 in total

1.  A non-contact vital sign monitoring system for ambulances using dual-frequency microwave radars.

Authors:  Satoshi Suzuki; Takemi Matsui; Hiroshi Kawahara; Hiroto Ichiki; Jun Shimizu; Yoko Kondo; Shinji Gotoh; Hirofumi Yura; Bonpei Takase; Masayuki Ishihara
Journal:  Med Biol Eng Comput       Date:  2008-10-23       Impact factor: 2.602

2.  Electrically insulated sensing of respiratory rate and heartbeat using optical fibers.

Authors:  Ernesto Suaste-Gómez; Daniel Hernández-Rivera; Anabel S Sánchez-Sánchez; Elsy Villarreal-Calva
Journal:  Sensors (Basel)       Date:  2014-11-14       Impact factor: 3.576

3.  Simultaneous measurement of two biological signals using a multi-layered polyvinylidene fluoride sensor.

Authors:  Long-Nguyen Manh; Jinghua Li; Hyunkyu Kweon; Younghun Chae
Journal:  Sci Rep       Date:  2022-01-27       Impact factor: 4.379

4.  The Structure Design of Piezoelectric Poly(vinylidene Fluoride) (PVDF) Polymer-Based Sensor Patch for the Respiration Monitoring under Dynamic Walking Conditions.

Authors:  Kin-Fong Lei; Yi-Zheng Hsieh; Yi-Yuan Chiu; Min-Hsien Wu
Journal:  Sensors (Basel)       Date:  2015-07-31       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.