A correction method for nonlinear artifacts in CT imaging.

Haining Sun1, Shaokun Qiu, Shanshan Lou, Jinjun Liu, Changjun Li, Genmiao Jiang.   

Abstract

This work presents a new method to reduce nonlinear artifacts in computed tomography (CT). Based on the traditional water-equivalent beam hardening correction method, a new systematic iterative algorithm has been designed to modify the original spectrum, which is under the influences of certain added filter materials and some unknown factors. By incorporating the characters of polychromatic beam hardening and the insensibility and nonuniformity of detectors into consideration, a new polynomial function curve is calculated. The curve can calibrate CT raw data and reduce the nonlinear artifacts, such as shading artifacts, dark artifacts, cupping artifacts and ring artifacts, in soft tissue. Comparing with the traditional water-equivalent correction, results show that this method can significantly improve the image quality. Meanwhile, the method is pre-processing and will not increase the normal reconstruction time. That is, all the time-consuming works can be done before scanning patients. However, it is still depending on the size of phantoms currently used, and more detailed works need to be done in the future.

Entities:  

Year:  2004        PMID: 17271926     DOI: 10.1109/IEMBS.2004.1403407

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  Dual energy computed tomography quantification of carotid plaques calcification: comparison between monochromatic and polychromatic energies with pathology correlation.

Authors:  Lorenzo Mannelli; Lawrence MacDonald; Marcello Mancini; Marina Ferguson; William P Shuman; Monica Ragucci; Serena Monti; Dongxiang Xu; Chun Yuan; Lee M Mitsumori
Journal:  Eur Radiol       Date:  2014-12-24       Impact factor: 5.315

2.  Changes in measured size of atherosclerotic plaque calcifications in dual-energy CT of ex vivo carotid endarterectomy specimens: effect of monochromatic keV image reconstructions.

Authors:  Lorenzo Mannelli; Lee M Mitsumori; Marina Ferguson; Dongxiang Xu; Baocheng Chu; Kelley R Branch; William P Shuman; Chun Yuan
Journal:  Eur Radiol       Date:  2012-08-21       Impact factor: 5.315

3.  Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom.

Authors:  Hyo-Jin Kang; Jeong Min Lee; Sang Min Lee; Hyun Kyung Yang; Ri Hyeon Kim; Ju Gang Nam; Aruna Karnawat; Joon Koo Han
Journal:  BMC Med Imaging       Date:  2019-08-28       Impact factor: 1.930

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.