Literature DB >> 17271886

New power loss optimized Fontan connection evaluated by calculation of power loss using high resolution PC-MRI and CFD.

D D Soerensen1, K Pekkan, K S Sundareswaran, A P Yoganathan.   

Abstract

A new blood vessel configuration was invented to optimize blood flow efficiency and reduce the power loss in the Fontan connection. The current preferred Fontan configuration, the total cavopulmonary connection (TCPC), usually connects the venae cava (VC) to the pulmonary arteries (PA), bypassing the right ventricle. The new connection, called OptiFlo, has two vertical inlets, which both bifurcate then merge into one another to form two horizontal outlets. One of the preliminary configurations of the new OptiFlo model was used for a comparison experiment between computational fluid dynamics (CFD) and high resolution phase contrast magnetic resonance imaging (PC-MRI) with a voxel resolution of 0.23 mmx0.23 mmx0.25 mm. The thin slice thickness was achieved using the ACGI interpolation technique we have used in other applications before. The 2D PC-MRI velocity vectors were mapped into a CFD grid, enabling direct CFD and MRI data comparisons. The mean squared difference was found between the two dataset Using the viscous power dissipation function we calculated the power loss for both CFD and MRI data. The power losses, calculated with the viscous power dissipation function, were 0.66 mW for CFD and 0.46 mW for the PC-MRI data.

Entities:  

Year:  2004        PMID: 17271886     DOI: 10.1109/IEMBS.2004.1403367

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  7 in total

Review 1.  Computer modeling to tailor therapy for congenital heart disease.

Authors:  Michael A Quail; Andrew M Taylor
Journal:  Curr Cardiol Rep       Date:  2013-09       Impact factor: 2.931

2.  Hemodynamic study of TCPC using in vivo and in vitro 4D Flow MRI and numerical simulation.

Authors:  Alejandro Roldán-Alzate; Sylvana García-Rodríguez; Petros V Anagnostopoulos; Shardha Srinivasan; Oliver Wieben; Christopher J François
Journal:  J Biomech       Date:  2015-03-19       Impact factor: 2.712

3.  The Advantages of Viscous Dissipation Rate over Simplified Power Loss as a Fontan Hemodynamic Metric.

Authors:  Zhenglun Alan Wei; Michael Tree; Phillip M Trusty; Wenjun Wu; Shelly Singh-Gryzbon; Ajit Yoganathan
Journal:  Ann Biomed Eng       Date:  2017-11-01       Impact factor: 3.934

4.  Hemodynamic performance of stage-2 univentricular reconstruction: Glenn vs. hemi-Fontan templates.

Authors:  Kerem Pekkan; Lakshimi P Dasi; Diane de Zélicourt; Kartik S Sundareswaran; Mark A Fogel; Kirk R Kanter; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2008-11-06       Impact factor: 3.934

5.  Patient-specific surgical planning and hemodynamic computational fluid dynamics optimization through free-form haptic anatomy editing tool (SURGEM).

Authors:  Kerem Pekkan; Brian Whited; Kirk Kanter; Shiva Sharma; Diane de Zelicourt; Kartik Sundareswaran; David Frakes; Jarek Rossignac; Ajit P Yoganathan
Journal:  Med Biol Eng Comput       Date:  2008-08-05       Impact factor: 2.602

Review 6.  Fontan Surgical Planning: Previous Accomplishments, Current Challenges, and Future Directions.

Authors:  Phillip M Trusty; Timothy C Slesnick; Zhenglun Alan Wei; Jarek Rossignac; Kirk R Kanter; Mark A Fogel; Ajit P Yoganathan
Journal:  J Cardiovasc Transl Res       Date:  2018-01-16       Impact factor: 4.132

Review 7.  Right ventricle-pulmonary circulation dysfunction: a review of energy-based approach.

Authors:  Namheon Lee; Michael D Taylor; Rupak K Banerjee
Journal:  Biomed Eng Online       Date:  2015-01-09       Impact factor: 2.819

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.