Release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick-type artificial lumbar disc (Medtronic Sofamor Danek).

Alexander Zeh1, Michael Planert, Gabriele Siegert, Peter Lattke, Andreas Held, Werner Hein.   

Abstract

STUDY
DESIGN: Cross-sectional study of 10 patients to measure the serum levels of cobalt and chromium after TDA.
OBJECTIVES: To investigate the release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick-type artificial lumbar disc. SUMMARY OF BACKGROUND DATA: In total hip endoprosthetics and consequently for TDA (total disc arthroplasty), metal-on-metal combinations are used with the aim of reducing wear debris. In metal-on-metal TDA the release of metal ions has until now been secondary to the main discussion.
MATERIALS AND METHODS: We investigated the serum cobalt and chromium concentration following implantation of 15 Maverick TDAs (monosegmental L5-S1, n = 5; bisegmental L4-L5 and L5-S1, n = 5; average age, 36.5 years). Five healthy subjects (no metal implants) acted as a control group. The measurements of the metals were carried out using the HITACHI Z-8200 AAS polarized Zeeman atomic absorption spectrometer after an average of 14.8 months.
RESULTS: The concentrations of cobalt and chromium ions in the serum amounted on average to 4.75 microg/L (SD, 2.71) for cobalt and 1.10 microg/L (SD, 1.24) for chromium. Compared with control group, both the chromium and cobalt levels in the serum showed significant increases (Mann-Whitney U test, P = 0.0120). At follow-up,the Oswestry Disability Score was on average significantly decreased by 24.4 points (L5-S1) (t test, P < 0.05) and by 26.8 points (L4-S1) (t test, P < 0.05). The improved clinical situation is also represented by a significant decrease of the Visual Analog Pain Scale of 42.2 points after the follow-up (t test, P < 0.05).
CONCLUSION: Significant systemic release of Cr/Co was proven in the serum compared with the control group. The concentrations of Cr/Co measured in the serum are similar in terms of their level to the values measured in THA metal-on-metal combinations or exceed these values given in the literature. Long-term implication of this metal exposure is unknown and should be studied further.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17268267     DOI: 10.1097/01.brs.0000253599.89694.c0

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  19 in total

1.  Influence of lumbar intervertebral disc degeneration on the outcome of total lumbar disc replacement: a prospective clinical, histological, X-ray and MRI investigation.

Authors:  Christoph J Siepe; Franziska Heider; Elisabeth Haas; Wolfgang Hitzl; Ulrike Szeimies; Axel Stäbler; Christoph Weiler; Andreas G Nerlich; Michael H Mayer
Journal:  Eur Spine J       Date:  2012-05-29       Impact factor: 3.134

Review 2.  [Revision surgery after implantation of a vertebral disc prosthesis].

Authors:  C Hopf
Journal:  Orthopade       Date:  2008-04       Impact factor: 1.087

Review 3.  Design concepts in lumbar total disc arthroplasty.

Authors:  Fabio Galbusera; Chiara M Bellini; Thomas Zweig; Stephen Ferguson; Manuela T Raimondi; Claudio Lamartina; Marco Brayda-Bruno; Maurizio Fornari
Journal:  Eur Spine J       Date:  2008-10-23       Impact factor: 3.134

Review 4.  Which design and biomaterial factors affect clinical wear performance of total disc replacements? A systematic review.

Authors:  Sai Y Veruva; Marla J Steinbeck; Jeffrey Toth; Dominik D Alexander; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

5.  Lumbar total disc replacement: does it still need further follow-up?

Authors:  Chun-Kun Park
Journal:  J Spine Surg       Date:  2017-09

6.  Evaluation of impingement behaviour in lumbar spinal disc arthroplasty.

Authors:  Thomas M Grupp; James J Yue; Rolando Garcia; Christian Kaddick; Bernhard Fritz; Christoph Schilling; Jens Schwiesau; Wilhelm Blömer
Journal:  Eur Spine J       Date:  2014-06-06       Impact factor: 3.134

7.  Are periprosthetic tissue reactions observed after revision of total disc replacement comparable to the reactions observed after total hip or knee revision surgery?

Authors:  Ilona M Punt; Shennah Austen; Jack P M Cleutjens; Steven M Kurtz; René H M ten Broeke; Lodewijk W van Rhijn; Paul C Willems; André van Ooij
Journal:  Spine (Phila Pa 1976)       Date:  2012-01-15       Impact factor: 3.468

8.  Prospective study on serum metal levels in patients with metal-on-metal lumbar disc arthroplasty.

Authors:  Matthew F Gornet; J K Burkus; M L Harper; F W Chan; A K Skipor; J J Jacobs
Journal:  Eur Spine J       Date:  2012-11-20       Impact factor: 3.134

Review 9.  Metal-on-Metal Bearing: Is This the End of the Line? We Do Not Think So.

Authors:  Henri Migaud; Sophie Putman; Antoine Combes; Charles Berton; Donatien Bocquet; Laurent Vasseur; Julien Girard
Journal:  HSS J       Date:  2012-09-11

10.  We Need to Talk about Lumbar Total Disc Replacement.

Authors:  Stephen Beatty
Journal:  Int J Spine Surg       Date:  2018-08-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.