Literature DB >> 17264368

Projection-data based temporal maximum attenuation computed tomography: determination of internal target volume for lung cancer against intra-fraction motion.

Shinichiro Mori1, Nobuyuki Kanematsu, Hiroshi Asakura, Masahiro Endo.   

Abstract

The concept of internal target volume (ITV) is highly significant in radiotherapy for the lung, an organ which is hampered by organ motion. To date, different methods to obtain the ITV have been published and are therefore available. To define ITV, we developed a new method by adapting a time filter to the four-dimensional CT scan technique (4DCT) which is projection-data processing (4D projection data maximum attenuation (4DPM)), and compared it with reconstructed image processing (4D image maximum intensity projection (4DIM)) using a phantom and clinical evaluations. 4DIM and 4DPM captured accurate maximum intensity volume (MIV), that is tumour encompassing volume, easily. Although 4DIM increased the CT number 1.8 times higher than 4DPM, 4DPM provided the original tumour CT number for MIV via a reconstruction algorithm. In the patient with lung fibrosis honeycomb, the MIV with 4DIM is 0.7 cm larger than that for cine imaging in the cranio-caudal direction. 4DPM therefore provided an accurate MIV independent of patient characteristics and reconstruction conditions. These findings indicate the usefulness of 4DPM in determining ITV in radiotherapy.

Entities:  

Mesh:

Year:  2007        PMID: 17264368     DOI: 10.1088/0031-9155/52/4/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  A treatment planning strategy for heavy-charged-particle radiotherapy of lung cancer by the use of computed tomography with projection data-based temporal maximum-intensity projection.

Authors:  Hiroshi Asakura; Motoki Kumagai; Nobuyuki Kanematsu; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2009-12-10

2.  2D-3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery.

Authors:  Wen Pei Liu; Yoshito Otake; Mahdi Azizian; Oliver J Wagner; Jonathan M Sorger; Mehran Armand; Russell H Taylor
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-12-12       Impact factor: 2.924

3.  Comparison of internal target volumes defined by three-dimensional, four-dimensional, and cone-beam computed tomography images of a motion phantom.

Authors:  Yu Wang; Tao Liu; Huiqin Chen; Penggang Bai; Qiong Zhan; Xiaohua Liang
Journal:  Ann Transl Med       Date:  2020-11
  3 in total