Literature DB >> 17264367

A voxel-based mouse for internal dose calculations using Monte Carlo simulations (MCNP).

A Bitar1, A Lisbona, P Thedrez, C Sai Maurel, D Le Forestier, J Barbet, M Bardies.   

Abstract

Murine models are useful for targeted radiotherapy pre-clinical experiments. These models can help to assess the potential interest of new radiopharmaceuticals. In this study, we developed a voxel-based mouse for dosimetric estimates. A female nude mouse (30 g) was frozen and cut into slices. High-resolution digital photographs were taken directly on the frozen block after each section. Images were segmented manually. Monoenergetic photon or electron sources were simulated using the MCNP4c2 Monte Carlo code for each source organ, in order to give tables of S-factors (in Gy Bq-1 s-1) for all target organs. Results obtained from monoenergetic particles were then used to generate S-factors for several radionuclides of potential interest in targeted radiotherapy. Thirteen source and 25 target regions were considered in this study. For each source region, 16 photon and 16 electron energies were simulated. Absorbed fractions, specific absorbed fractions and S-factors were calculated for 16 radionuclides of interest for targeted radiotherapy. The results obtained generally agree well with data published previously. For electron energies ranging from 0.1 to 2.5 MeV, the self-absorbed fraction varies from 0.98 to 0.376 for the liver, and from 0.89 to 0.04 for the thyroid. Electrons cannot be considered as 'non-penetrating' radiation for energies above 0.5 MeV for mouse organs. This observation can be generalized to radionuclides: for example, the beta self-absorbed fraction for the thyroid was 0.616 for I-131; absorbed fractions for Y-90 for left kidney-to-left kidney and for left kidney-to-spleen were 0.486 and 0.058, respectively. Our voxel-based mouse allowed us to generate a dosimetric database for use in preclinical targeted radiotherapy experiments.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17264367     DOI: 10.1088/0031-9155/52/4/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

Review 1.  Preclinical animal research on therapy dosimetry with dual isotopes.

Authors:  Mark W Konijnenberg; Marion de Jong
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-01       Impact factor: 9.236

2.  Synthesis and preclinical evaluation of an Al18F radiofluorinated GLU-UREA-LYS(AHX)-HBED-CC PSMA ligand.

Authors:  Stefano Boschi; Jason T Lee; Seval Beykan; Roger Slavik; Liu Wei; Claudio Spick; Uta Eberlein; Andreas K Buck; Filippo Lodi; Gianfranco Cicoria; Johannes Czernin; Michael Lassmann; Stefano Fanti; Ken Herrmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-06-22       Impact factor: 9.236

3.  Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies.

Authors:  D Welch; A D Harken; G Randers-Pehrson; D J Brenner
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

4.  Pretargeted radioimmunotherapy of colorectal cancer metastases: models and pharmacokinetics predict influence of the physical and radiochemical properties of the radionuclide.

Authors:  Eric Frampas; Catherine Maurel; Patricia Remaud-Le Saëc; Thibault Mauxion; Alain Faivre-Chauvet; François Davodeau; David M Goldenberg; Manuel Bardiès; Jacques Barbet
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-20       Impact factor: 9.236

5.  Monte carlo simulation of an X-ray pixel beam microirradiation system.

Authors:  E C Schreiber; S X Chang
Journal:  Radiat Res       Date:  2009-03       Impact factor: 2.841

6.  Effect of emaciation and obesity on small-animal internal radiation dosimetry for positron-emitting radionuclides.

Authors:  Tianwu Xie; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-07-02       Impact factor: 9.236

7.  Assessment of S values in stylized and voxel-based rat models for positron-emitting radionuclides.

Authors:  Tianwu Xie; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2013-10       Impact factor: 3.488

8.  Murine-specific Internal Dosimetry for Preclinical Investigations of Imaging and Therapeutic Agents.

Authors:  Bryan Bednarz; Joseph Grudzinski; Ian Marsh; Abby Besemer; Dana Baiu; Jamey Weichert; Mario Otto
Journal:  Health Phys       Date:  2018-04       Impact factor: 1.316

9.  Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators.

Authors:  Matthew D Belley; Chu Wang; Giao Nguyen; Rathnayaka Gunasingha; Nelson J Chao; Benny J Chen; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

Review 10.  Preclinical Voxel-Based Dosimetry in Theranostics: a Review.

Authors:  Arun Gupta; Min Sun Lee; Joong Hyun Kim; Dong Soo Lee; Jae Sung Lee
Journal:  Nucl Med Mol Imaging       Date:  2020-04-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.