Literature DB >> 17263319

Ultratrace LC/MS proteomic analysis using 10-microm-i.d. Porous layer open tubular poly(styrene-divinylbenzene) capillary columns.

Guihua Yue1, Quanzhou Luo, Jian Zhang, Shiaw-Lin Wu, Barry L Karger.   

Abstract

In this paper, the preparation and performance of long, high-efficiency poly(styrene-divinylbenzene) (PS-DVB), 10-microm-i.d. porous layer open tubular (PLOT) capillary columns are described. PLOT capillaries ( approximately 3% RSD column-to-column retention time), with relatively high permeability, were prepared by in-situ polymerization. Relatively high loading capacities, approximately 100 fmol for angiotensin I and approximately 50 fmol for insulin, were obtained with a 4.2 m x 10-microm-i.d. PLOT column. Low detection levels (attomole to sub-attomole) were achieved when the column was coupled on-line with a linear ion trap MS (LTQ). Analysis of human epidermal growth factor receptor (EGFR), a large transmembrane tyrosine kinase receptor with heterogeneous phosphorylation and glycosylation structures, was obtained at the 25 fmol level. The PLOT column yielded a peak capacity of approximately 400 for the separation of a complex tryptic digest mixture when the sample preparation included a 50-microm-i.d. PS-DVB monolithic precolumn and ESI-MS detection. As an example of the power of the column, 3046 unique peptides covering 566 distinct Methanosarcina acetivorans proteins were identified from a 50 ng in-gel tryptic digest sample combining five cuts in a single LC/MS/MS analysis using the LTQ. The results demonstrate the potential of the PLOT column for high-resolution LC/MS at the ultratrace level.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17263319     DOI: 10.1021/ac061411m

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  26 in total

1.  An Integrated Platform for Isolation, Processing, and Mass Spectrometry-based Proteomic Profiling of Rare Cells in Whole Blood.

Authors:  Siyang Li; Brian D Plouffe; Arseniy M Belov; Somak Ray; Xianzhe Wang; Shashi K Murthy; Barry L Karger; Alexander R Ivanov
Journal:  Mol Cell Proteomics       Date:  2015-03-09       Impact factor: 5.911

2.  Capillary-based multi nanoelectrospray emitters: improvements in ion transmission efficiency and implementation with capillary reversed-phase LC-ESI-MS.

Authors:  Ryan T Kelly; Jason S Page; Rui Zhao; Wei-Jun Qian; Heather M Mottaz; Keqi Tang; Richard D Smith
Journal:  Anal Chem       Date:  2007-11-29       Impact factor: 6.986

3.  Ultrasensitive and fast bottom-up analysis of femtogram amounts of complex proteome digests.

Authors:  Liangliang Sun; Guijie Zhu; Yimeng Zhao; Xiaojing Yan; Si Mou; Norman J Dovichi
Journal:  Angew Chem Int Ed Engl       Date:  2013-10-31       Impact factor: 15.336

4.  Microproteomic analysis of 10,000 laser captured microdissected breast tumor cells using short-range sodium dodecyl sulfate-polyacrylamide gel electrophoresis and porous layer open tubular liquid chromatography tandem mass spectrometry.

Authors:  Dipak Thakur; Tomas Rejtar; Dongdong Wang; Jonathan Bones; Sangwon Cha; Buffie Clodfelder-Miller; Elizabeth Richardson; Shemeica Binns; Sonika Dahiya; Dennis Sgroi; Barry L Karger
Journal:  J Chromatogr A       Date:  2011-09-14       Impact factor: 4.759

Review 5.  Single-cell Proteomics: Progress and Prospects.

Authors:  Ryan T Kelly
Journal:  Mol Cell Proteomics       Date:  2020-08-26       Impact factor: 5.911

6.  Tapered-Tip Capillary Electrophoresis Nano-Electrospray Ionization Mass Spectrometry for Ultrasensitive Proteomics: the Mouse Cortex.

Authors:  Sam B Choi; Marta Zamarbide; M Chiara Manzini; Peter Nemes
Journal:  J Am Soc Mass Spectrom       Date:  2016-11-16       Impact factor: 3.109

7.  The revolution and evolution of shotgun proteomics for large-scale proteome analysis.

Authors:  John R Yates
Journal:  J Am Chem Soc       Date:  2013-01-16       Impact factor: 15.419

8.  Two-dimensional strong cation exchange/porous layer open tubular/mass spectrometry for ultratrace proteomic analysis using a 10 microm id poly(styrene- divinylbenzene) porous layer open tubular column with an on-line triphasic trapping column.

Authors:  Quanzhou Luo; Ye Gu; Shiaw-Lin Wu; Tomas Rejtar; Barry L Karger
Journal:  Electrophoresis       Date:  2008-04       Impact factor: 3.535

Review 9.  CEC: selected developments that caught my eye since the year 2000.

Authors:  Frantisek Svec
Journal:  Electrophoresis       Date:  2009-06       Impact factor: 3.535

10.  Optimization of the porous structure and polarity of polymethacrylate-based monolithic capillary columns for the LC-MS separation of enzymatic digests.

Authors:  Sebastiaan Eeltink; Laurent Geiser; Frantisek Svec; Jean M J Fréchet
Journal:  J Sep Sci       Date:  2007-11       Impact factor: 3.645

View more