Literature DB >> 17260136

A binary matrix for background suppression in MALDI-MS of small molecules.

Zhong Guo1, Lin He.   

Abstract

Application of matrix-assisted laser-desorption ionization mass spectrometry (MALDI-MS) to small-molecule detection is often limited, because of high matrix background signals in the low-mass region. We report here an approach in which a mixture of two conventional MALDI matrices with different proton affinity was used to suppress the formation of matrix clusters and fragments. Specifically, when acidic alpha-cyano-4-hydroxycinnamic acid (CHCA) and basic 9-aminoacridine (9-AA) were used as the binary matrix, fewer background matrix peaks were observed in both positive and negative-mode detection of small molecules. In addition, the presence of CHCA substantially reduced the laser fluence needed for analyte desorption and ionization; thus better signal-to-background ratios were observed for negatively charged inositol phosphates in complex plant extracts.

Entities:  

Year:  2007        PMID: 17260136     DOI: 10.1007/s00216-006-1100-3

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  13 in total

1.  MALDI imaging of lipid biochemistry in tissues by mass spectrometry.

Authors:  Karin A Zemski Berry; Joseph A Hankin; Robert M Barkley; Jeffrey M Spraggins; Richard M Caprioli; Robert C Murphy
Journal:  Chem Rev       Date:  2011-09-26       Impact factor: 60.622

2.  Enzyme-coupled nanoparticles-assisted laser desorption ionization mass spectrometry for searching for low-mass inhibitors of enzymes in complex mixtures.

Authors:  Aleksander Salwiński; David Da Silva; Raphaël Delépée; Benoît Maunit
Journal:  J Am Soc Mass Spectrom       Date:  2014-02-19       Impact factor: 3.109

3.  A binary matrix for the rapid detection and characterization of small-molecule cardiovascular drugs by MALDI-MS and MS/MS.

Authors:  Jinlan Dong; Wenjing Ning; Daniel J Mans; Jamie D Mans
Journal:  Anal Methods       Date:  2018-02-01       Impact factor: 2.896

4.  Conformational Differentiation of α-Cyanohydroxycinnamic Acid Isomers: A Raman Spectroscopic Study.

Authors:  Jayson Vedad; Maciej E Domaradzki; Elmer-Rico E Mojica; Emmanuel J Chang; Adam A Profit; Ruel Z B Desamero
Journal:  J Raman Spectrosc       Date:  2017-07-27       Impact factor: 3.133

5.  Towards a second generation of ionic liquid matrices (ILMs) for MALDI-MS of peptides, proteins, and carbohydrates.

Authors:  Jeffrey A Crank; Daniel W Armstrong
Journal:  J Am Soc Mass Spectrom       Date:  2009-07-01       Impact factor: 3.109

Review 6.  From pixel to voxel: a deeper view of biological tissue by 3D mass spectral imaging.

Authors:  Hui Ye; Tyler Greer; Lingjun Li
Journal:  Bioanalysis       Date:  2011-02       Impact factor: 2.681

7.  SALDI-MS signal enhancement using oxidized graphitized carbon black nanoparticles.

Authors:  Nahid Amini; Mohammadreza Shariatgorji; Gunnar Thorsén
Journal:  J Am Soc Mass Spectrom       Date:  2009-02-21       Impact factor: 3.109

8.  A novel strategy for MALDI-TOF MS analysis of small molecules.

Authors:  Shu Zhang; Jian'an Liu; Yi Chen; Shaoxiang Xiong; Guanghui Wang; Jun Chen; Guoqiang Yang
Journal:  J Am Soc Mass Spectrom       Date:  2009-10-06       Impact factor: 3.109

9.  Matrix-assisted laser desorption/ionization time-of-flight mass spectrometric analysis of cellular glycerophospholipids enabled by multiplexed solvent dependent analyte-matrix interactions.

Authors:  Gang Sun; Kui Yang; Zhongdan Zhao; Shaoping Guan; Xianlin Han; Richard W Gross
Journal:  Anal Chem       Date:  2008-09-04       Impact factor: 6.986

10.  Carbon Dots and 9AA as a Binary Matrix for the Detection of Small Molecules by Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry.

Authors:  Yongli Chen; Dan Gao; Hangrui Bai; Hongxia Liu; Shuo Lin; Yuyang Jiang
Journal:  J Am Soc Mass Spectrom       Date:  2016-04-13       Impact factor: 3.109

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.