Literature DB >> 17242228

Isotropic 3D fast spin-echo with proton-density-like contrast: a comprehensive approach to musculoskeletal MRI.

Lawrence Yao1, John T Pitts, David Thomasson.   

Abstract

OBJECTIVE: Scanning time considerations have restricted routine use of 3D Fourier transform (3DFT)-encoded MRI to gradient-recalled echo sequences. We sought to combine isotropic 3DFT acquisition with fast spin-echo at a practical scan duration. This strategy offers versatile image contrast for musculoskeletal evaluation and facilitates image reformation tailored to the depiction of small anatomic features.
CONCLUSION: Isotropic 3DFT fast spin-echo is feasible on current MRI scanners and has the potential to improve musculoskeletal evaluation.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17242228     DOI: 10.2214/AJR.06.0556

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  12 in total

1.  MRI diagnosis of ACL bundle tears: value of oblique axial imaging.

Authors:  Alex W H Ng; James F Griffith; Esther H Y Hung; Kan Yip Law; Patrick S H Yung
Journal:  Skeletal Radiol       Date:  2012-02-21       Impact factor: 2.199

2.  Diagnostic performance of wrist magnetic resonance (MR) arthrography: comparison of three-dimensional isotropic T1 weighted fast spin-echo MR arthrography and two-dimensional MR arthrography.

Authors:  Eunsun Oh; Young C Yoon; Min J Park
Journal:  Br J Radiol       Date:  2017-02-15       Impact factor: 3.039

3.  MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences.

Authors:  Giovanni Foti; Paolo Avanzi; William Mantovani; Flavia Dal Corso; Emanuele Demozzi; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2017-02-15       Impact factor: 3.469

4.  Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences.

Authors:  Faysal F Altahawi; Kevin J Blount; Nicholas P Morley; Esther Raithel; Imran M Omar
Journal:  Skeletal Radiol       Date:  2016-10-15       Impact factor: 2.199

5.  MRI of the anterior talofibular ligament, talar cartilage and os subfibulare: Comparison of isotropic resolution 3D and conventional 2D T2-weighted fast spin-echo sequences at 3.0 T.

Authors:  Jisook Yi; Jang Gyu Cha; Young Koo Lee; Bo Ra Lee; Chan Hong Jeon
Journal:  Skeletal Radiol       Date:  2016-03-19       Impact factor: 2.199

Review 6.  Routine 3D magnetic resonance imaging of joints.

Authors:  Richard Kijowski; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

7.  Accelerating Knee MRI: 3D Modulated Flip-Angle Technique in Refocused Imaging with an Extended Echo Train and Compressed Sensing.

Authors:  He Sui; Jin Li; Lin Liu; Zhongwen Lv; Yunfei Zhang; Yongming Dai; Zhanhao Mo
Journal:  J Pain Res       Date:  2022-02-25       Impact factor: 3.133

8.  Diagnostic performance of in vivo 3-T MRI for articular cartilage abnormalities in human osteoarthritic knees using histology as standard of reference.

Authors:  Ehsan Saadat; Bjoern Jobke; Bill Chu; Ying Lu; Jonathan Cheng; Xiaojuan Li; Michael D Ries; Sharmila Majumdar; Thomas M Link
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

9.  Comparison of three-dimensional isotropic and two-dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears.

Authors:  Ji Hyun Lee; Young Cheol Yoon; Sukkyung Jee; Jong Won Kwon; Jang Gyu Cha; Jae Chul Yoo
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

10.  Diagnostic performance of 3D SPACE for comprehensive knee joint assessment at 3 T.

Authors:  Pieter Van Dyck; Jan L Gielen; Filip M Vanhoenacker; Eline De Smet; Kristien Wouters; Lieven Dossche; Paul M Parizel
Journal:  Insights Imaging       Date:  2012-10-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.