Literature DB >> 17237652

A computer model of the pediatric circulatory system for testing pediatric assist devices.

Guruprasad A Giridharan1, Steven C Koenig, Michael Mitchell, Mark Gartner, George M Pantalos.   

Abstract

Lumped parameter computer models of the pediatric circulatory systems for 1- and 4-year-olds were developed to predict hemodynamic responses to mechanical circulatory support devices. Model parameters, including resistance, compliance and volume, were adjusted to match hemodynamic pressure and flow waveforms, pressure-volume loops, percent systole, and heart rate of pediatric patients (n = 6) with normal ventricles. Left ventricular failure was modeled by adjusting the time-varying compliance curve of the left heart to produce aortic pressures and cardiac outputs consistent with those observed clinically. Models of pediatric continuous flow (CF) and pulsatile flow (PF) ventricular assist devices (VAD) and intraaortic balloon pump (IABP) were developed and integrated into the heart failure pediatric circulatory system models. Computer simulations were conducted to predict acute hemodynamic responses to PF and CF VAD operating at 50%, 75% and 100% support and 2.5 and 5 ml IABP operating at 1:1 and 1:2 support modes. The computer model of the pediatric circulation matched the human pediatric hemodynamic waveform morphology to within 90% and cardiac function parameters with 95% accuracy. The computer model predicted PF VAD and IABP restore aortic pressure pulsatility and variation in end-systolic and end-diastolic volume, but diminish with increasing CF VAD support.

Entities:  

Mesh:

Year:  2007        PMID: 17237652     DOI: 10.1097/01.mat.0000247154.02260.30

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  5 in total

1.  Cavopulmonary assist for the failing Fontan circulation: impact of ventricular function on mechanical support strategy.

Authors:  Guruprasad A Giridharan; Mickey Ising; Michael A Sobieski; Steven C Koenig; Jun Chen; Steven Frankel; Mark D Rodefeld
Journal:  ASAIO J       Date:  2014 Nov-Dec       Impact factor: 2.872

2.  International conference on pediatric mechanical circulatory support systems and pediatric cardiopulmonary perfusion: outcomes and future directions.

Authors:  Akif Undar
Journal:  ASAIO J       Date:  2008 Mar-Apr       Impact factor: 2.872

3.  Performance evaluation of a pediatric viscous impeller pump for Fontan cavopulmonary assist.

Authors:  Guruprasad A Giridharan; Steven C Koenig; Jeffrey Kennington; Michael A Sobieski; Jun Chen; Steven H Frankel; Mark D Rodefeld
Journal:  J Thorac Cardiovasc Surg       Date:  2012-03-14       Impact factor: 5.209

4.  Scaling the Low-Shear Pulsatile TORVAD for Pediatric Heart Failure.

Authors:  Jeffrey R Gohean; Erik R Larson; Brian H Hsi; Mark Kurusz; Richard W Smalling; Raul G Longoria
Journal:  ASAIO J       Date:  2017 Mar/Apr       Impact factor: 2.872

5.  Patient-Specific Modelling and Parameter Optimisation to Simulate Dilated Cardiomyopathy in Children.

Authors:  Selim Bozkurt; Waleed Paracha; Kaushiki Bakaya; Silvia Schievano
Journal:  Cardiovasc Eng Technol       Date:  2022-02-22       Impact factor: 2.495

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.