Technical evaluation of dialysate flow in a newly designed dialyzer.

Ken-Ichiro Yamamoto1, Hiroaki Matsukawa, Taiji Yakushiji, Makoto Fukuda, Tatsuo Hiyoshi, Kiyotaka Sakai.   

Abstract

Rexeed was developed by Asahi Kasei Medical using wave-shaped hollow fibers, a full baffle, and a short taper housing to improve dialysate flow. The present study is clarifies improvement in dialysate flow with Rexeed-15 compared with that of a conventional dialyzer. Dialysate flow was evaluated by the pulse-response method. Dialysate pressure and tracer concentration were measured at a blood-side flow rate (QBeta) of 200 ml/min, a dialysate-side flow rate (QD) of 500 ml/min, and a net filtration rate (QF) of 0 ml/min using needles placed in the test dialyzer. Dialyzer performance was evaluated by measuring urea and vitamin B12 clearance at QB = 200 and 400 ml/min, QD = 300-800 ml/min, and QF = 0 ml/min. In the conventional dialyzer, dialysate channeling was observed. In contrast, Rexeed-15 had a uniform dialysate flow. Urea and vitamin B12 clearance with Rexeed-15 was slightly sensitive to QD. The overall mass transfer coefficient for urea with Rexeed-15 was more than 50% higher than that of the conventional dialyzer, indicating the possibility of reduced dialysate usage with Rexeed. Rexeed has a highly optimal dialysate flow, due to the wave-shaped hollow fibers and the new housing, and gives increased clearance for lower-molecular-weight substances.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17237647     DOI: 10.1097/01.mat.0000245525.83936.79

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  6 in total

1.  Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities.

Authors:  Ayaka Hirano; Shoko Kida; Ken-ichiro Yamamoto; Kiyotaka Sakai
Journal:  J Artif Organs       Date:  2011-11-25       Impact factor: 1.731

2.  Technical characterization of dialysis fluid flow and mass transfer rate in dialyzers with various filtration coefficients using dimensionless correlation equation.

Authors:  Makoto Fukuda; Kengo Yoshimura; Koki Namekawa; Kiyotaka Sakai
Journal:  J Artif Organs       Date:  2017-01-13       Impact factor: 1.731

3.  Dialysate flow rate and delivered Kt/Vurea for dialyzers with enhanced dialysate flow distribution.

Authors:  Richard A Ward; John W Idoux; Hiba Hamdan; Rosemary Ouseph; Thomas A Depner; Thomas A Golper
Journal:  Clin J Am Soc Nephrol       Date:  2011-07-28       Impact factor: 8.237

4.  Effect of increasing dialysate flow rate on diffusive mass transfer of urea, phosphate and beta2-microglobulin during clinical haemodialysis.

Authors:  Jai P Bhimani; Rosemary Ouseph; Richard A Ward
Journal:  Nephrol Dial Transplant       Date:  2010-06-13       Impact factor: 5.992

Review 5.  Eco-dialysis: fashion or necessity.

Authors:  Monika Wieliczko; Jacek Zawierucha; Adrian Covic; Tomasz Prystacki; Wojciech Marcinkowski; Jolanta Małyszko
Journal:  Int Urol Nephrol       Date:  2020-02-01       Impact factor: 2.370

6.  Enhancement of solute clearance using pulsatile push-pull dialysate flow for the Quanta SC+: A novel clinic-to-home haemodialysis system.

Authors:  Clive Buckberry; Nicholas Hoenich; Detlef Krieter; Horst-Dieter Lemke; Marieke Rüth; John E Milad
Journal:  PLoS One       Date:  2020-03-02       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.