Literature DB >> 17237585

Detecting REM sleep from the finger: an automatic REM sleep algorithm based on peripheral arterial tone (PAT) and actigraphy.

Sarah Herscovici1, Avivit Pe'er, Surik Papyan, Peretz Lavie.   

Abstract

Scoring of REM sleep based on polysomnographic recordings is a laborious and time-consuming process. The growing number of ambulatory devices designed for cost-effective home-based diagnostic sleep recordings necessitates the development of a reliable automatic REM sleep detection algorithm that is not based on the traditional electroencephalographic, electrooccolographic and electromyographic recordings trio. This paper presents an automatic REM detection algorithm based on the peripheral arterial tone (PAT) signal and actigraphy which are recorded with an ambulatory wrist-worn device (Watch-PAT100). The PAT signal is a measure of the pulsatile volume changes at the finger tip reflecting sympathetic tone variations. The algorithm was developed using a training set of 30 patients recorded simultaneously with polysomnography and Watch-PAT100. Sleep records were divided into 5 min intervals and two time series were constructed from the PAT amplitudes and PAT-derived inter-pulse periods in each interval. A prediction function based on 16 features extracted from the above time series that determines the likelihood of detecting a REM epoch was developed. The coefficients of the prediction function were determined using a genetic algorithm (GA) optimizing process tuned to maximize a price function depending on the sensitivity, specificity and agreement of the algorithm in comparison with the gold standard of polysomnographic manual scoring. Based on a separate validation set of 30 patients overall sensitivity, specificity and agreement of the automatic algorithm to identify standard 30 s epochs of REM sleep were 78%, 92%, 89%, respectively. Deploying this REM detection algorithm in a wrist worn device could be very useful for unattended ambulatory sleep monitoring. The innovative method of optimization using a genetic algorithm has been proven to yield robust results in the validation set.

Entities:  

Mesh:

Year:  2006        PMID: 17237585     DOI: 10.1088/0967-3334/28/2/002

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  17 in total

Review 1.  Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation.

Authors:  Nancy A Collop; Sharon L Tracy; Vishesh Kapur; Reena Mehra; David Kuhlmann; Sam A Fleishman; Joseph M Ojile
Journal:  J Clin Sleep Med       Date:  2011-10-15       Impact factor: 4.062

2.  Sleep staging based on autonomic signals: a multi-center validation study.

Authors:  Jan Hedner; David P White; Atul Malhotra; Sarah Herscovici; Stephen D Pittman; Ding Zou; Ludger Grote; Giora Pillar
Journal:  J Clin Sleep Med       Date:  2011-06-15       Impact factor: 4.062

3.  Watch What You're Doing!

Authors:  John C Carter; Dennis Auckley
Journal:  J Clin Sleep Med       Date:  2018-03-15       Impact factor: 4.062

4.  Obstructive Sleep Apnea Severity is Directly Related to Suicidal Ideation in Posttraumatic Stress Disorder.

Authors:  Madhulika A Gupta; Patricia Jarosz
Journal:  J Clin Sleep Med       Date:  2018-03-15       Impact factor: 4.062

5.  Sleep Parameter Assessment Accuracy of a Consumer Home Sleep Monitoring Ballistocardiograph Beddit Sleep Tracker: A Validation Study.

Authors:  Jarno Tuominen; Karoliina Peltola; Tarja Saaresranta; Katja Valli
Journal:  J Clin Sleep Med       Date:  2019-03-15       Impact factor: 4.062

6.  Validation of Watch-PAT-200 against polysomnography during pregnancy.

Authors:  Louise M O'Brien; Alexandra S Bullough; Anita V Shelgikar; Mark C Chames; Roseanne Armitage; Ronald D Chervin
Journal:  J Clin Sleep Med       Date:  2012-06-15       Impact factor: 4.062

7.  Pediatric Obstructive Sleep Apnea: What's in a Name?

Authors:  Allan Damian; David Gozal
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 3.650

8.  Reliability of the Watch-PAT 200 in detecting sleep apnea in highway bus drivers.

Authors:  Melike Yuceege; Hikmet Firat; Ahmet Demir; Sadik Ardic
Journal:  J Clin Sleep Med       Date:  2013-04-15       Impact factor: 4.062

9.  Assessment of a portable monitoring device WatchPAT 200 in the diagnosis of obstructive sleep apnea.

Authors:  Li Weimin; Wang Rongguang; Huang Dongyan; Liu Xiaoli; Jin Wei; Yang Shiming
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-05-25       Impact factor: 2.503

10.  Sleep Monitoring Using WatchPAT Device to Predict Recurrence of Major Depression in Patients at High Risk for Major Depression Disorder Recurrence: A Case Report.

Authors:  Daniel Harlev; Ramit Ravona-Springer; Yonatan Nuriel; Eyal Fruchter
Journal:  Front Psychiatry       Date:  2021-06-25       Impact factor: 4.157

View more