Literature DB >> 17235366

Optical-CT imaging of complex 3D dose distributions.

Mark Oldham, Leonard Kim, Geoffrey Hugo.   

Abstract

The limitations of conventional dosimeters restrict the comprehensiveness of verification that can be performed for advanced radiation treatments presenting an immediate and substantial problem for clinics attempting to implement these techniques. In essence, the rapid advances in the technology of radiation delivery have not been paralleled by corresponding advances in the ability to verify these treatments. Optical-CT gel-dosimetry is a relatively new technique with potential to address this imbalance by providing high resolution 3D dose maps in polymer and radiochromic gel dosimeters. We have constructed a 1(st) generation optical-CT scanner capable of high resolution 3D dosimetry and applied it to a number of simple and increasingly complex dose distributions including intensity-modulated-radiation-therapy (IMRT). Prior to application to IMRT, the robustness of optical-CT gel dosimetry was investigated on geometry and variable attenuation phantoms. Physical techniques and image processing methods were developed to minimize deleterious effects of refraction, reflection, and scattered laser light. Here we present results of investigations into achieving accurate high-resolution 3D dosimetry with optical-CT, and show clinical examples of 3D IMRT dosimetry verification. In conclusion, optical-CT gel dosimetry can provide high resolution 3D dose maps that greatly facilitate comprehensive verification of complex 3D radiation treatments. Good agreement was observed at high dose levels (>50%) between planned and measured dose distributions. Some systematic discrepancies were observed however (rms discrepancy 3% at high dose levels) indicating further work is required to eliminate confounding factors presently compromising the accuracy of optical-CT 3D gel-dosimetry.

Year:  2005        PMID: 17235366      PMCID: PMC1773258          DOI: 10.1117/12.595525

Source DB:  PubMed          Journal:  J Phys Conf Ser        ISSN: 1742-6588


  8 in total

1.  High resolution gel-dosimetry by optical-CT and MR scanning.

Authors:  M Oldham; J H Siewerdsen; A Shetty; D A Jaffray
Journal:  Med Phys       Date:  2001-07       Impact factor: 4.071

2.  Optical-CT gel-dosimetry I: basic investigations.

Authors:  Mark Oldham; Jeffrey H Siewerdsen; Sai Kumar; John Wong; David A Jaffray
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

3.  Optical-CT gel-dosimetry. II: Optical artifacts and geometrical distortion.

Authors:  Mark Oldham; Leonard Kim
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

4.  Evaluation of a 2D diode array for IMRT quality assurance.

Authors:  Daniel Létourneau; Misbah Gulam; Di Yan; Mark Oldham; John W Wong
Journal:  Radiother Oncol       Date:  2004-02       Impact factor: 6.280

5.  Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry.

Authors:  C Baldock; R P Burford; N Billingham; G S Wagner; S Patval; R D Badawi; S F Keevil
Journal:  Phys Med Biol       Date:  1998-03       Impact factor: 3.609

6.  Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner.

Authors:  J C Gore; M Ranade; M J Maryañski; R J Schulz
Journal:  Phys Med Biol       Date:  1996-12       Impact factor: 3.609

Review 7.  Radiation dosimetry using polymer gels: methods and applications.

Authors:  M McJury; M Oldham; V P Cosgrove; P S Murphy; S Doran; M O Leach; S Webb
Journal:  Br J Radiol       Date:  2000-09       Impact factor: 3.039

8.  Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter.

Authors:  R G Kelly; K J Jordan; J J Battista
Journal:  Med Phys       Date:  1998-09       Impact factor: 4.071

  8 in total
  3 in total

1.  3D dosimetry by optical-CT scanning.

Authors:  Mark Oldham
Journal:  J Phys Conf Ser       Date:  2006

2.  Validation of a Prototype Optical Computed Tomography System.

Authors:  Seyed Salman Zakariaee; Mikaeil Molazadeh; Abbas Takavar; Alireza Shirazi; Asghar Mesbahi; Ahad Zeinali
Journal:  J Med Signals Sens       Date:  2015 Apr-Jun

3.  Design and construction of an optical computed tomography scanner for polymer gel dosimetry application.

Authors:  Seyed Salman Zakariaee; Asghar Mesbahi; Ahmad Keshtkar; Vahid Azimirad
Journal:  J Med Signals Sens       Date:  2014-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.