The influence of metal artefacts on the range of ion beams.

Oliver Jäkel1, Petra Reiss.   

Abstract

The influence of artefacts due to metal implants on the range of ion beams is investigated, using a geometrically well-defined head and pelvic phantom together with inserts from steel, titanium and tungsten. The ranges along various beam paths including artefacts were calculated from the TPS and compared to known calculations for phantoms without any insert. In the head phantom, beams intersecting the streak artefacts lead to errors in the range of around or below 1%, which is mainly due to a cancellation of various effects. Beams through the metal or close to it show an underestimation of 3.5% of the range for tungsten. For the pelvic phantom, a large underestimation of the range is observed for a lateral path through the metal insert. In the case of tungsten and steel, range errors of -5% and -18% are observed, respectively. Such beam paths are typically used for pelvic tumours in radiotherapy with ion beams. For beams in the anterior-posterior direction through the inserts, an overestimation of ion ranges of up to 3% for titanium and 8% for steel is expected, respectively. Beam paths outside the metal insert show a large cancellation for the lateral beams (leading to errors of around 1% only) and somewhat higher errors for anterior-posterior beams (around 3% for titanium and 6% for steel). The analysis of CT data of patients with dental implants of gold as compared to patients with healthy teeth also showed a significant effect of the artefacts on the distribution of HU in the data, namely a redistribution of HU to higher and lower values as compared to patients with healthy teeth. The corresponding mean range variation was a 2.5% reduction in the data with artefacts as compared to the data without artefacts. It is concluded that beam paths through metal implants should generally be avoided in proton and ion therapy. In this case, the underestimation of ion range due to artefacts alone may amount to 3% for dental fillings and up to 5% and 18% for hip prosthesis made of titanium and steel, respectively. It is important to note that the size of the metal inserts cannot be determined correctly from the images, so that a correction of the ranges in metal also leads to large uncertainties. Finally, it should be stressed that the stated relative deviations are strictly valid only for the investigated phantoms and can only give a rough estimate on the size of range uncertainties that may appear in real patients.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17228110     DOI: 10.1088/0031-9155/52/3/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  23 in total

1.  Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning.

Authors:  Jan Unkelbach; Thomas Bortfeld; Benjamin C Martin; Martin Soukup
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

2.  Dosimetric accuracy of proton therapy for chordoma patients with titanium implants.

Authors:  Joost M Verburg; Joao Seco
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

3.  Site-specific range uncertainties caused by dose calculation algorithms for proton therapy.

Authors:  J Schuemann; S Dowdell; C Grassberger; C H Min; H Paganetti
Journal:  Phys Med Biol       Date:  2014-07-03       Impact factor: 3.609

4.  Determination of the dynamics of healing at the tissue-implant interface by means of microcomputed tomography and functional apparent moduli.

Authors:  Po-Chun Chang; Yang-Jo Seol; Steven A Goldstein; William V Giannobile
Journal:  Int J Oral Maxillofac Implants       Date:  2013 Jan-Feb       Impact factor: 2.804

5.  Can megavoltage computed tomography reduce proton range uncertainties in treatment plans for patients with large metal implants?

Authors:  Wayne D Newhauser; Annelise Giebeler; Katja M Langen; Dragan Mirkovic; Radhe Mohan
Journal:  Phys Med Biol       Date:  2008-04-17       Impact factor: 3.609

Review 6.  Range uncertainties in proton therapy and the role of Monte Carlo simulations.

Authors:  Harald Paganetti
Journal:  Phys Med Biol       Date:  2012-05-09       Impact factor: 3.609

7.  Inter-fraction robustness of intensity-modulated proton therapy in the post-operative treatment of oropharyngeal and oral cavity squamous cell carcinomas.

Authors:  Christina Hague; Marianne Aznar; Lei Dong; Alireza Fotouhi-Ghiam; Lip Wai Lee; Taoran Li; Alexander Lin; Matthew Lowe; John N Lukens; Andrew McPartlin; Shannon O'Reilly; Nick Slevin; Samuel Swisher-Mcclure; David Thomson; Marcel Van Herk; Catharine West; Wei Zou; Boon-Keng Kevin Teo
Journal:  Br J Radiol       Date:  2019-12-23       Impact factor: 3.039

8.  Technical Note: validation of a material assignment method for a retrospective study of carbon-ion radiotherapy using Monte Carlo simulation.

Authors:  Weishan Chang; Yusuke Koba; Takuya Furuta; Shunsuke Yonai; Shintaro Hashimoto; Shinnosuke Matsumoto; Tatsuhiko Sato
Journal:  J Radiat Res       Date:  2021-09-13       Impact factor: 2.724

9.  Technical advances and pitfalls in head and neck radiotherapy.

Authors:  Upendra Parvathaneni; George E Laramore; Jay J Liao
Journal:  J Oncol       Date:  2012-05-30       Impact factor: 4.375

10.  Monitoring of patients treated with particle therapy using positron-emission-tomography (PET): the MIRANDA study.

Authors:  Stephanie E Combs; Julia Bauer; Daniel Unholtz; Christopher Kurz; Thomas Welzel; Daniel Habermehl; Thomas Haberer; Jürgen Debus; Katia Parodi
Journal:  BMC Cancer       Date:  2012-04-03       Impact factor: 4.430

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.