Literature DB >> 17227092

Effect of varus/valgus malalignment on bone strains in the proximal tibia after TKR: an explicit finite element study.

A Perillo-Marcone1, M Taylor.   

Abstract

Malalignment is the main cause of tibial component loosening. Implants that migrate rapidly in the first two post-operative years are likely to present aseptic loosening. It has been suggested that cancellous bone stresses can be correlated with tibial component migration. A recent study has shown that patient-specific finite element (FE) models have the power to predict the short-term behavior of tibial trays. The stresses generated within the implanted tibia are dependent on the kinematics of the joint; however, previous studies have ignored the kinematics and only applied static loads. Using explicit FE, it is possible to simultaneously predict the kinematics and stresses during a gait cycle. The aim of this study was to examine the cancellous bone strains during the stance phase of the gait cycle, for varying degrees of varus/valgus eccentric loading using explicit FE. A patient-specific model of a proximal tibia was created from CT scan images, including heterogeneous bone properties. The proximal tibia was implanted with a commercial total knee replacement (TKR) model. The stance phase of gait was simulated and the applied loads and boundary conditions were based on those used for the Stanmore knee simulator. Eccentric loading was simulated. As well as examining the tibial bone strains (minimum and maximum principal strain), the kinematics of the bone-implant construct are also reported. The maximum anterior-posterior displacements and internal-external rotations were produced by the model with 20 mm offset. The peak minimum and maximum principal strain values increased as the load was shifted laterally, reaching a maximum magnitude for -20 mm offset. This suggests that when in varus, the load transferred to the bone is shifted medially, and as the bone supporting this load is stiffer, the resulting peak bone strains are lower than when the load is shifted laterally (valgus). For this particular patient, the TKR design analyzed produced the highest cancellous bone strains when in valgus. This study has provided an insight in the variations produced in bone strain distribution when the axial load is applied eccentrically. To the authors' knowledge, this is the first time that the bone strain distribution of a proximal implanted tibia has been examined, also accounting for the kinematics of the tibio-femoral joint as part of the simulation. This approach gives greater insight into the overall performance of TKR.

Entities:  

Mesh:

Year:  2007        PMID: 17227092     DOI: 10.1115/1.2401177

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  16 in total

1.  Loss of tibial bone density in patients with rotating- or fixed-platform TKA.

Authors:  Jacob T Munro; Salil Pandit; Cameron G Walker; Mark Clatworthy; Rocco P Pitto
Journal:  Clin Orthop Relat Res       Date:  2009-03-26       Impact factor: 4.176

2.  Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA.

Authors:  Michael T Hirschmann; Felix Amsler; Helmut Rasch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-06-06       Impact factor: 9.236

3.  Stress shielding in the bony chain of leg in presence of varus or valgus knee.

Authors:  Vincenzo Filardi
Journal:  J Orthop       Date:  2014-07-17

4.  Improving tibial component alignment in total knee arthroplasty.

Authors:  G Cinotti; P Sessa; A D'Arino; F R Ripani; G Giannicola
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-14       Impact factor: 4.342

5.  Painful knee arthroplasty: current practice.

Authors:  Umberto Cottino; Federica Rosso; Antonio Pastrone; Federico Dettoni; Roberto Rossi; Matteo Bruzzone
Journal:  Curr Rev Musculoskelet Med       Date:  2015-12

Review 6.  Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.

Authors:  J Gallo; S B Goodman; Y T Konttinen; M A Wimmer; M Holinka
Journal:  Acta Biomater       Date:  2013-05-10       Impact factor: 8.947

7.  Arthroplasty in the Valgus Knee: Comparison and Discussion of Lateral vs Medial Parapatellar Approaches and Implant Selection.

Authors:  Jai Rawal; Adam J Devany; James A Jeffery
Journal:  Open Orthop J       Date:  2015-05-15

8.  Development and validation of a computational model of the knee joint for the evaluation of surgical treatments for osteoarthritis.

Authors:  R Mootanah; C W Imhauser; F Reisse; D Carpanen; R W Walker; M F Koff; M W Lenhoff; S R Rozbruch; A T Fragomen; Z Dewan; Y M Kirane; K Cheah; J K Dowell; H J Hillstrom
Journal:  Comput Methods Biomech Biomed Engin       Date:  2014-05-01       Impact factor: 1.763

9.  Computational study on the effect of malalignment of the tibial component on the biomechanics of total knee arthroplasty: A Finite Element Analysis.

Authors:  D-S Suh; K-T Kang; J Son; O-R Kwon; C Baek; Y-G Koh
Journal:  Bone Joint Res       Date:  2017-11       Impact factor: 5.853

10.  Effects of tibial torsion on distal alignment of extramedullary instrumentation in total knee arthroplasty.

Authors:  Gianluca Cinotti; Pasquale Sessa; Antonello Della Rocca; Francesca Romana Ripani; Giuseppe Giannicola
Journal:  Acta Orthop       Date:  2013-04-17       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.