Literature DB >> 17220185

Effect of simultaneous intracoronary guidewires on the predictive accuracy of functional parameters of coronary lesion severity.

Hein J Verberne1, Martijn Meuwissen, Steven A J Chamuleau, Bart-Jan Verhoeff, Berthe L F van Eck-Smit, Jos A E Spaan, Jan J Piek, Maria Siebes.   

Abstract

The aim of this study was to assess the influence of a second guidewire on the diagnostic accuracy of functional parameters of coronary lesion severity. Sixty-five patients with intermediate coronary lesions underwent myocardial perfusion scintigraphy. Fractional flow reserve (FFR), coronary flow velocity reserve (CFVR), and hyperemic stenosis resistance (HSR) index (HSR = stenosis pressure gradient / velocity) were determined in 77 lesions. Distal pressure and velocity were acquired simultaneously (dual wire) and sequentially (single wire) with two sensor-equipped guidewires. Overall, functional parameters deteriorated from single- to dual-wire assessment. In patients without ischemia, the good diagnostic performance of FFR, CFVR, and HSR deteriorated significantly (P < 0.001) when assessed by dual wires, with an increase in the number of false-positive results. This trend was more pronounced for HSR, since the presence of a second wire reduced maximal velocity and increased the pressure gradient. The presence of two guidewires, especially across a myocardial perfusion scintigraphy-induced nonsignificant lesion, is associated with overestimation of the hemodynamically assessed lesion severity and, therefore, is likely to have a major impact on clinical decision making. This underscores the advantage of a dual-sensor-equipped guidewire for the evaluation of stenosis severity by combined pressure and velocity measurements.

Entities:  

Mesh:

Year:  2007        PMID: 17220185     DOI: 10.1152/ajpheart.01042.2006

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  8 in total

Review 1.  Theoretical models for coronary vascular biomechanics: progress & challenges.

Authors:  Sarah L Waters; Jordi Alastruey; Daniel A Beard; Peter H M Bovendeerd; Peter F Davies; Girija Jayaraman; Oliver E Jensen; Jack Lee; Kim H Parker; Aleksander S Popel; Timothy W Secomb; Maria Siebes; Spencer J Sherwin; Rebecca J Shipley; Nicolas P Smith; Frans N van de Vosse
Journal:  Prog Biophys Mol Biol       Date:  2010-10-30       Impact factor: 3.667

2.  Differences in cardiac microcirculatory wave patterns between the proximal left mainstem and proximal right coronary artery.

Authors:  Nearchos Hadjiloizou; Justin E Davies; Iqbal S Malik; Jazmin Aguado-Sierra; Keith Willson; Rodney A Foale; Kim H Parker; Alun D Hughes; Darrel P Francis; Jamil Mayet
Journal:  Am J Physiol Heart Circ Physiol       Date:  2008-07-18       Impact factor: 4.733

3.  Characteristics of the flow velocity-pressure gradient relation in the assessment of stenoses: an in vitro study.

Authors:  K M J Marques; N Westerhof
Journal:  Neth Heart J       Date:  2008-05       Impact factor: 2.380

Review 4.  Myocardial perfusion distribution and coronary arterial pressure and flow signals: clinical relevance in relation to multiscale modeling, a review.

Authors:  Froukje Nolte; Eoin R Hyde; Cristina Rolandi; Jack Lee; Pepijn van Horssen; Kal Asrress; Jeroen P H M van den Wijngaard; Andrew N Cookson; Tim van de Hoef; Radomir Chabiniok; Reza Razavi; Christian Michler; Gilion L T F Hautvast; Jan J Piek; Marcel Breeuwer; Maria Siebes; Eike Nagel; Nic P Smith; Jos A E Spaan
Journal:  Med Biol Eng Comput       Date:  2013-07-27       Impact factor: 2.602

5.  Effect of guidewire on contribution of loss due to momentum change and viscous loss to the translesional pressure drop across coronary artery stenosis: an analytical approach.

Authors:  Ehsan Rajabi-Jaghargh; Kranthi K Kolli; Lloyd H Back; Rupak K Banerjee
Journal:  Biomed Eng Online       Date:  2011-06-10       Impact factor: 2.819

Review 6.  Review of zero-D and 1-D models of blood flow in the cardiovascular system.

Authors:  Yubing Shi; Patricia Lawford; Rodney Hose
Journal:  Biomed Eng Online       Date:  2011-04-26       Impact factor: 2.819

7.  Fractional flow reserve derived from microcatheters versus standard pressure wires: a stenosis-level meta-analysis.

Authors:  Henry Seligman; Matthew J Shun-Shin; Anushkumar Vasireddy; Christopher Cook; Yousif Y Ahmad; James Howard; Sayan Sen; Rasha Al-Lamee; Sukhjinder Nijjer; Daniel Chamie; Justin Davies; Jamil Mayet; Darrel P Francis; Ricardo Petraco
Journal:  Open Heart       Date:  2019-03-25

8.  Hemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study.

Authors:  Rupak K Banerjee; Koustubh D Ashtekar; Tarek A Helmy; Mohamed A Effat; Lloyd H Back; Saeb F Khoury
Journal:  Biomed Eng Online       Date:  2008-08-27       Impact factor: 2.819

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.