BACKGROUND: Acute studies in cardiac resynchronization therapy (CRT) showed that hemodynamic effects may depend on the coronary sinus (CS) lead position. However, there are no data on the longterm effect of CS lead position. METHODS: In 45 heart failure patients with left bundle branch block and QRS >150 ms (age 59+/-10 years, 17 dilative cardiomyopathy, 23 ischemic, 5 valvular), biventricular pacemakers were implanted. CS leads were positioned in posterior (P, n=15), lateral (L, n=19) or, if no other option available, anterior (A, n=11) side branches. Before and 6 months after implantation, clinical state, echocardiography, brain natriuretic peptide (BNP) and right heart catheterization were evaluated. RESULTS: Baseline parameters were similar between groups. After 6 months, there were 32/34 responders in groups P and L compared to 7/11 responders in group A (94 vs groups P and L: Arterial pressure +8 and +9% vs +2%; PCWP -23 and -15% vs -4%, pulmonary pressure -18 and -12% vs -3% (p<0.01 for A vs P+L); cardiac index +21 and +12% vs +11% (p=0.03 for A vs P). BNP was reduced by 55, 35, and 27% (p=0.05 for A vs P). Ejection fraction increased in P and L by 40 and 41%, respectively, but only by +19% in A (p<0.03 for A vs P+L). CONCLUSION: Chronic CRT improves ejection fraction, BNP and hemodynamic measurements predominantly in patients with lateral and posterior CS lead positions. Anterior lead positions should be avoided.
BACKGROUND: Acute studies in cardiac resynchronization therapy (CRT) showed that hemodynamic effects may depend on the coronary sinus (CS) lead position. However, there are no data on the longterm effect of CS lead position. METHODS: In 45 heart failurepatients with left bundle branch block and QRS >150 ms (age 59+/-10 years, 17 dilative cardiomyopathy, 23 ischemic, 5 valvular), biventricular pacemakers were implanted. CS leads were positioned in posterior (P, n=15), lateral (L, n=19) or, if no other option available, anterior (A, n=11) side branches. Before and 6 months after implantation, clinical state, echocardiography, brain natriuretic peptide (BNP) and right heart catheterization were evaluated. RESULTS: Baseline parameters were similar between groups. After 6 months, there were 32/34 responders in groups P and L compared to 7/11 responders in group A (94 vs groups P and L: Arterial pressure +8 and +9% vs +2%; PCWP -23 and -15% vs -4%, pulmonary pressure -18 and -12% vs -3% (p<0.01 for A vs P+L); cardiac index +21 and +12% vs +11% (p=0.03 for A vs P). BNP was reduced by 55, 35, and 27% (p=0.05 for A vs P). Ejection fraction increased in P and L by 40 and 41%, respectively, but only by +19% in A (p<0.03 for A vs P+L). CONCLUSION: Chronic CRT improves ejection fraction, BNP and hemodynamic measurements predominantly in patients with lateral and posterior CS lead positions. Anterior lead positions should be avoided.
Authors: Sylvain Reuter; Stephane Garrigue; S Serge Barold; Pierre Jais; Meleze Hocini; Michel Haissaguerre; Jacques Clementy Journal: Am J Cardiol Date: 2002-02-01 Impact factor: 2.778
Authors: William T Abraham; Westby G Fisher; Andrew L Smith; David B Delurgio; Angel R Leon; Evan Loh; Dusan Z Kocovic; Milton Packer; Alfredo L Clavell; David L Hayes; Myrvin Ellestad; Robin J Trupp; Jackie Underwood; Faith Pickering; Cindy Truex; Peggy McAtee; John Messenger Journal: N Engl J Med Date: 2002-06-13 Impact factor: 91.245
Authors: Michael R Bristow; Leslie A Saxon; John Boehmer; Steven Krueger; David A Kass; Teresa De Marco; Peter Carson; Lorenzo DiCarlo; David DeMets; Bill G White; Dale W DeVries; Arthur M Feldman Journal: N Engl J Med Date: 2004-05-20 Impact factor: 91.245
Authors: M H Hamdan; J D Zagrodzky; J A Joglar; C J Sheehan; K Ramaswamy; J F Erdner; R L Page; M L Smith Journal: Circulation Date: 2000-08-29 Impact factor: 29.690
Authors: John G F Cleland; Jean-Claude Daubert; Erland Erdmann; Nick Freemantle; Daniel Gras; Lukas Kappenberger; Luigi Tavazzi Journal: N Engl J Med Date: 2005-03-07 Impact factor: 91.245
Authors: Lu Chen; Jay E Tiongson; Sebastian Obrzut; Martin B McDaniel; Hsin-Yi Chang; Jigar Patel; Paul J Friedman; Gregory K Feld; Ulrika M Birgersdotter-Green Journal: J Interv Card Electrophysiol Date: 2012-07-28 Impact factor: 1.900