Literature DB >> 17209116

Improving mammographic decision accuracy by incorporating observer ratings with interpretation time.

R S Saunders1, E Samei.   

Abstract

Mammography is currently the most established technique for the early detection of breast cancer. However, mammography would benefit from further improvements as it does produce some errors, such as not finding all early-stage cancers. The objectives of this study were first, to measure the timing of correct and incorrect reading decisions in mammography and second, to exploit those dependencies to improve accuracy in mammographic interpretation. To address these objectives, an experiment was conducted where experienced breast imaging radiologists reviewed 400 mammographic regions equally divided among images that contained simulated benign masses, malignant masses, malignant microcalcifications and no lesions. The experiment recorded the radiologists' decision as well as the length of time the mammogram was interpreted in. The experiment results showed that incorrect detection as well as incorrect classification decisions were associated with longer interpretation times (p<0.0001). The timing results were used to create a model that would flag cases for review that had a higher probability of error. The flagged cases had a median accuracy drop of 13% for detection decisions and 16% for classification decisions compared with unflagged cases. This suggests that interpretation time can be incorporated into mammographic decision-making in order to identify cases with higher probabilities of perceptual error that require further review.

Entities:  

Mesh:

Year:  2006        PMID: 17209116     DOI: 10.1259/bjr/96931332

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  5 in total

1.  Effect of greyscale liquid crystal displays of different resolutions on observer performance during detection of small solitary pulmonary nodules.

Authors:  J Yin; Q Guo; W Zhang; H Su; J Zhang; Y Yue; C Ding; A Lin; Y Wang; H Wang
Journal:  Br J Radiol       Date:  2012-06-27       Impact factor: 3.039

2.  Influence of study design in receiver operating characteristics studies: sequential versus independent reading.

Authors:  Steven Schalekamp; Bram van Ginneken; Cornelia M Schaefer-Prokop; Nico Karssemeijer
Journal:  J Med Imaging (Bellingham)       Date:  2014-04-23

3.  Is confidence of mammographic assessment a good predictor of accuracy?

Authors:  Berta M Geller; Andy Bogart; Patricia A Carney; Joann G Elmore; Barbara S Monsees; Diana L Miglioretti
Journal:  AJR Am J Roentgenol       Date:  2012-07       Impact factor: 3.959

4.  Strategies for improved interpretation of computer-aided detections for CT colonography utilizing distributed human intelligence.

Authors:  Matthew T McKenna; Shijun Wang; Tan B Nguyen; Joseph E Burns; Nicholas Petrick; Ronald M Summers
Journal:  Med Image Anal       Date:  2012-05-03       Impact factor: 8.545

5.  Association between time spent interpreting, level of confidence, and accuracy of screening mammography.

Authors:  Patricia A Carney; T Andrew Bogart; Berta M Geller; Sebastian Haneuse; Karla Kerlikowske; Diana S M Buist; Robert Smith; Robert Rosenberg; Bonnie C Yankaskas; Tracy Onega; Diana L Miglioretti
Journal:  AJR Am J Roentgenol       Date:  2012-04       Impact factor: 3.959

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.