Correction of compliance and resistance altered by endotracheal tube leaks and non-linear pressure/volume-relationships.

Werner Nikischin1, Malte Lange.   

Abstract

Measurements of lung compliance (C) and resistance (R) are influenced by endotracheal tube leaks (ETTL) as well as non-linear pressure/volume relationships (P/V relationship). To keep C and R reliable, we developed an algorithm to mathematically correct inspiratory and expiratory volume (V) and flow. In this study, a ventilated lung model for non-linear P/V relationship with adjustment of an increasing ETTL was studied. In addition, the recordings (airway pressure, flow, and volume) of 21 infants (median weight: 1,220 g, range: 640-2,160 g, with a median leak size of 32%, range: 24-56%) were investigated. C and R were calculated continuously from the recordings of flow, volume, and airway pressure over time according to the changing volume. A method especially developed for the analysis of non-linear pressure-volume-relationship (APVNL) was employed. C and R affected by leaks were corrected applying the newly developed mathematical algorithm and compared with measurements without leakage. C could be corrected up to a leak of 80% and R up to 55% leak at half tidal V for the model with non-linear P/V-R. C and R without leak and after leak correction did not differ significantly in all infants where the APVNL method was applied (P > 0.05).

Entities:  

Mesh:

Year:  2007        PMID: 17206444     DOI: 10.1007/s00421-006-0339-x

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  15 in total

1.  A new method to analyze lung compliance when pressure-volume relationship is nonlinear.

Authors:  K Muramatsu; K Yukitake
Journal:  Am J Respir Crit Care Med       Date:  1999-06       Impact factor: 21.405

2.  Static volume-pressure relations of excised lungs of infants with hyaline membrane disease, newborn and stillborn infants.

Authors:  I GRIBETZ; N R FRANK; M E AVERY
Journal:  J Clin Invest       Date:  1959-12       Impact factor: 14.808

3.  Influence of tidal volume on the compliance of the respiratory system in mechanically ventilated newborn infants.

Authors:  C Popow; G Simbruner
Journal:  Wien Klin Wochenschr       Date:  1989-04-28       Impact factor: 1.704

4.  A new method to analyze lung compliance when pressure-volume relationship is nonlinear.

Authors:  W Nikischin; T Gerhardt; R Everett; E Bancalari
Journal:  Am J Respir Crit Care Med       Date:  1998-10       Impact factor: 21.405

5.  Leak measurements in spontaneously breathing premature newborns by using the flow-through technique.

Authors:  B Foitzik; M Schmidt; D Windstetter; R R Wauer; G Schmalisch
Journal:  J Appl Physiol (1985)       Date:  1998-09

6.  Respiratory mechanics during mechanical ventilation: a model study on the effects of leak around a tracheal tube.

Authors:  T Kondo; I Matsumoto; C J Lanteri; P D Sly
Journal:  Pediatr Pulmonol       Date:  1997-12

7.  Evaluation of neonatal pulmonary mechanics and energetics: a two factor least mean square analysis.

Authors:  V K Bhutani; E M Sivieri; S Abbasi; T H Shaffer
Journal:  Pediatr Pulmonol       Date:  1988

8.  Digital computer calculation of human pulmonary mechanics using a least squares fit technique.

Authors:  R R Uhl; F J Lewis
Journal:  Comput Biomed Res       Date:  1974-10

9.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

10.  Correction of compliance and resistance altered by endotracheal tube leaks.

Authors:  Werner Nikischin; Malte Lange
Journal:  Pediatr Crit Care Med       Date:  2003-07       Impact factor: 3.624

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.