Literature DB >> 17191185

Microincisional cataract surgery (MICS) with pulse and burst modes.

M Baykara1, I Ercan, H Ozcetin.   

Abstract

PURPOSE: To compare the amount of ultrasound (US) energy and balanced solution (BS) required for burst mode and pulse mode during bimanual phacoemulsification surgery.
METHODS: One hundred cases were divided into two groups (the pulse mode Group 1 [50 eyes], the burst mode Group 2 [50 eyes]). One surgeon (M.B.) performed phaco notemulsification procedures using topical anesthesia with the AMO Sovereign in all patients. The technique was based on the nuclear hardness and surgeon's criteria and performed bimanually. The surgery time, total ultrasound time (UST) and effective US power (USP), and used balanced solution (BS) were retrospectively compared.
RESULTS: The mean surgery time, mean UST, and mean used BS volume were not statistically different in both groups (p>0.05). The mean EPT was statistically highly different in both groups (p>0.001). There was a slight tendency toward more surgery time in Group 2 than in Group 1, although the difference was not significant (p=0.146). Statistically significant higher results (Group 1: r=0,889, p<0.001, and Group 2: r=0,834, p<0.001) were seen in Group 1 when both groups were evaluated for the surgery time and used BS volume. When UST and used BS volume were evaluated in Groups 1 and 2, significant relation was seen in both but the correlation is statistically higher in Group 1 (Group 1: r=0,765, p<0.001, and Group 2: r=0,544, p<0.001).
CONCLUSIONS: The very low energy modes with the WhiteStar technology are suitable for bimanual cataract surgery.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17191185     DOI: 10.1177/112067210601600604

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  4 in total

1.  Bimanual microincisional cataract surgery technique and clinical outcome.

Authors:  Abdulrahman Al-Muammar
Journal:  Saudi J Ophthalmol       Date:  2009-08-05

2.  Comparative clinical study of Whitestar Signature phacoemulsification system with standard and Ellips FX handpieces.

Authors:  Daniele Tognetto; Rossella D'Aloisio; Paolo Cecchini; Marta Di Nicola; Giuseppe Di Martino
Journal:  Int Ophthalmol       Date:  2017-07-13       Impact factor: 2.031

3.  An evaluation of intraoperative and postoperative outcomes of torsional mode versus longitudinal ultrasound mode phacoemulsification: a Meta-analysis.

Authors:  Pia Leon; Ingrid Umari; Alessandro Mangogna; Andrea Zanei; Daniele Tognetto
Journal:  Int J Ophthalmol       Date:  2016-06-18       Impact factor: 1.779

4.  Ultrasound power and irrigation volume in different lens opacity grades: comparison of femtosecond laser-assisted cataract surgery and conventional phacoemulsification.

Authors:  Guilherme A Horta; Rogério C Horta; Kátia Steinfeld; Camila R Koch; Glauco R Mello; Newton Kara-Junior
Journal:  Clinics (Sao Paulo)       Date:  2019-10-28       Impact factor: 2.365

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.