Literature DB >> 17189796

Intacs for the correction of keratoconus: two-year follow-up.

Joseph Colin1, Florence J Malet.   

Abstract

PURPOSE: To evaluate the long-term safety and efficacy of Intacs segments (Addition Technology, Inc.) for the treatment of keratoconus in terms of intraoperative and postoperative complications, visual outcome, restoration of contact lens tolerance, and inhibition of disease progression.
SETTING: Service d'Ophtalmologie, CHU Pellegrin, Bordeaux, France.
METHODS: This prospective, 2-year follow-up study comprised 100 keratoconic eyes with clear central corneas and contact lens intolerance. The best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA), refractive error, keratometry, pachymetry, and slitlamp examination were assessed preoperatively and 1 and 2 years after Intacs implantation.
RESULTS: At 2 years, the UCVA and BCVA improved in 80.5% and 68.3% of eyes, respectively (P<.001). The proportion of eyes with a BCVA >or=0.5 (20/40) increased from 22.0% at baseline to 51.2% and 53.7% at 1 year and 2 years, respectively (P<.001). The manifest refraction spherical equivalent improved from a mean of -6.93 diopters (D) +/- 3.91 (SD) preoperatively to -4.01 +/- 3.16 D at 1 year and -3.80 +/- 2.73 D at 2 years (P<.001). The mean keratometry readings decreased from 50.1 +/- 5.6 D preoperatively to 46.4 +/- 5.3 D at 1 year and 46.8 +/- 4.9 D at 2 years (P<.001). Contact lens tolerance was restored in over 80% of cases. Postoperative slitlamp observations revealed no clinically significant issues. The segments were removed from 4 eyes without complications or sequelae.
CONCLUSION: Intacs implantation was a safe and efficacious treatment for keratoconus. Significant and sustained improvements in objective visual outcomes were achieved in most cases, with restoration of contact lens tolerance.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17189796     DOI: 10.1016/j.jcrs.2006.08.057

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  17 in total

Review 1.  INTACS for keratoconus.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2006

2.  Implantable collamer lenses after intracorneal ring segments for keratoconus.

Authors:  Alejandro Navas; Guillermo Tapia-Herrera; Martha Jaimes; Enrique O Graue-Hernández; Arturo Gomez-Bastar; Tito Ramirez-Luquín; Arturo Ramirez-Miranda
Journal:  Int Ophthalmol       Date:  2012-05-12       Impact factor: 2.031

3.  Treatment of moderate to severe keratoconus with 6-mm Intacs SK.

Authors:  Sasan Niknam; Mehrdad Shamshiri; Seyed Sahabaldin Shahrzad; Abbas Alipour; Mohammad Bagher Rajabi; Mohammad Taher Rajabi
Journal:  Int J Ophthalmol       Date:  2012-08-18       Impact factor: 1.779

4.  Mathematical analysis of corneal remodelling after intracorneal ring surgery in keratoconus.

Authors:  Elias F Jarade; Elise Slim; Carole Cherfan; Hala El Rami; Toufic Hassan; Elias Chelala
Journal:  Int J Ophthalmol       Date:  2017-03-18       Impact factor: 1.779

Review 5.  INTACS for keratoconus and ectasia after LASIK.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2013

6.  Keratoconus: overview and update on treatment.

Authors:  Ladan Espandar; Jay Meyer
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

7.  Intrastromal corneal ring implants for corneal thinning disorders: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-04-01

8.  Nine-year follow-up of intacs implantation for keratoconus.

Authors:  George D Kymionis; Michael A Grentzelos; Vasilios F Diakonis; Aristofanis I Pallikaris; Ioannis G Pallikaris
Journal:  Open Ophthalmol J       Date:  2009-12-08

9.  Efficacy and safety of Intacs SK in moderate to severe keratoconus.

Authors:  Ahmed M El-Moatassem Kotb; Mohamed Hantera
Journal:  Middle East Afr J Ophthalmol       Date:  2013 Jan-Mar

10.  Partial visual rehabilitation using a toric implantable collamer lens in a patient with keratoconus: a case report with 20 months of follow-up.

Authors:  Sung Wook Park; Mee Kum Kim; Won Ryang Wee; Jin Hak Lee
Journal:  Korean J Ophthalmol       Date:  2013-04-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.