PURPOSE: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. METHODS AND MATERIALS: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in >10 patients).
RESULTS: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm.
CONCLUSION: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning.

Entities:  

Mesh:

Year:  2007        PMID: 17189078     DOI: 10.1016/j.ijrobp.2006.09.009

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  34 in total

1.  Esophagus and spinal cord motion relative to GTV motion in four-dimensional CTs of lung cancer patients.

Authors:  Elisabeth Weiss; Krishni Wijesooriya; Paul Keall
Journal:  Radiother Oncol       Date:  2008-02-21       Impact factor: 6.280

Review 2.  Noncalcified lung nodules: volumetric assessment with thoracic CT.

Authors:  Marios A Gavrielides; Lisa M Kinnard; Kyle J Myers; Nicholas Petrick
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

3.  Comparison of intensity-modulated radiotherapy planning based on manual and automatically generated contours using deformable image registration in four-dimensional computed tomography of lung cancer patients.

Authors:  Elisabeth Weiss; Krishni Wijesooriya; Viswanathan Ramakrishnan; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-12-19       Impact factor: 7.038

4.  Target tracking using DMLC for volumetric modulated arc therapy: a simulation study.

Authors:  Baozhou Sun; Dharanipathy Rangaraj; Lech Papiez; Swetha Oddiraju; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

5.  Development and validation of a prediction model for measurement variability of lung nodule volumetry in patients with pulmonary metastases.

Authors:  Eui Jin Hwang; Jin Mo Goo; Jihye Kim; Sang Joon Park; Soyeon Ahn; Chang Min Park; Yeong-Gil Shin
Journal:  Eur Radiol       Date:  2017-01-03       Impact factor: 5.315

6.  Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology.

Authors:  Edward D Brandner; Indrin J Chetty; Tawfik G Giaddui; Ying Xiao; M Saiful Huq
Journal:  Med Phys       Date:  2017-04-20       Impact factor: 4.071

7.  On correlated sources of uncertainty in four dimensional computed tomography data sets.

Authors:  Eric D Ehler; Wolfgang A Tome
Journal:  Technol Cancer Res Treat       Date:  2010-06

8.  Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Authors:  Amit Sawant; Raghu Venkat; Vikram Srivastava; David Carlson; Sergey Povzner; Herb Cattell; Paul Keall
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

9.  Evaluation of tumor motion effects on dose distribution for hypofractionated intensity-modulated radiotherapy of non-small-cell lung cancer.

Authors:  Hyejoo Kang; Ellen D Yorke; Jie Yang; Chen-Shou Chui; Kenneth E Rosenzweig; Howard I Amols
Journal:  J Appl Clin Med Phys       Date:  2010-06-08       Impact factor: 2.102

10.  Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm.

Authors:  Krishni Wijesooriya; E Weiss; V Dill; L Dong; R Mohan; S Joshi; P J Keall
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071