An in vivo rat model simulating imaging of human kidney by diagnostic ultrasound with gas-body contrast agent.

Douglas L Miller1, Chunyan Dou, Roger C Wiggins, Bryan L Wharram, Meera Goyal, Alun R Williams.   

Abstract

One kidney of anesthetized rats was imaged by diagnostic ultrasound with contrast agent under conditions simulating both the geometry and the attenuation encountered during human perfusion imaging. Contrary to earlier predictions, glomerular capillary rupture with blood loss into Bowman's space and proximal tubules occurred in our clinically relevant model system. Quantitative analysis of histologic sections showed that 37 +/- 5% of the glomeruli at the center of the scan plane had blood cells in Bowman's space after imaging for 1 min with 1.8 MPa (mechanical index equivalent, MIe = 1.5) with a 1 s image trigger interval during IV injection of 10 microl/kg/min of Definity contrast agent (as recommended by the manufacturer). This percentage decreased rapidly with decreasing peak rarefactional pressure amplitude to an apparent threshold of 0.73 MPa (MIe = 0.6). The percentage of glomeruli with hemorrhage decreased in proportion to dose when reduced below the recommended value, but leveled-off at doses above it. The percentage of glomerular hemorrhage increased with increasing numbers of image exposures, with an initial rate of 1.1% per image. The glomerular hemorrhage also depended on the frame trigger interval with no hemorrhage evident for continuous imaging but a maximal effect for trigger intervals greater than about 1 s. These results indicated that there is a potential for clinical diagnostic ultrasound with contrast agent to induce glomerular hemorrhage.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17189055     DOI: 10.1016/j.ultrasmedbio.2006.07.033

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  17 in total

Review 1.  Voiding urosonography with US contrast agent for the diagnosis of vesicoureteric reflux in children: an update.

Authors:  Kassa Darge
Journal:  Pediatr Radiol       Date:  2010-04-30

2.  Contrast-enhanced diagnostic ultrasound causes renal tissue damage in a porcine model.

Authors:  Douglas L Miller; Chunyan Dou; Roger C Wiggins
Journal:  J Ultrasound Med       Date:  2010-10       Impact factor: 2.153

3.  Needle size and injection rate impact microbubble contrast agent population.

Authors:  Esra Talu; Robert L Powell; Marjorie L Longo; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2008-03-04       Impact factor: 2.998

4.  Frequency dependence of kidney injury induced by contrast-aided diagnostic ultrasound in rats.

Authors:  Douglas L Miller; Chunyan Dou; Roger C Wiggins
Journal:  Ultrasound Med Biol       Date:  2008-05-15       Impact factor: 2.998

5.  An ex vivo study of the correlation between acoustic emission and microvascular damage.

Authors:  Stanley Samuel; Michol A Cooper; Joseph L Bull; J Brian Fowlkes; Douglas L Miller
Journal:  Ultrasound Med Biol       Date:  2009-06-27       Impact factor: 2.998

6.  Capillary Hemorrhage Induced by Contrast-Enhanced Diagnostic Ultrasound in Rat Intestine.

Authors:  Xiaofang Lu; Chunyan Dou; Mario L Fabiilli; Douglas L Miller
Journal:  Ultrasound Med Biol       Date:  2019-05-14       Impact factor: 2.998

7.  Contrast-enhanced voiding urosonography with intravesical administration of a second-generation ultrasound contrast agent for diagnosis of vesicoureteral reflux: prospective evaluation of contrast safety in 1,010 children.

Authors:  Frederica Papadopoulou; Aikaterini Ntoulia; Ekaterini Siomou; Kassa Darge
Journal:  Pediatr Radiol       Date:  2014-01-18

8.  A pilot study to assess markers of renal damage in the rodent kidney after exposure to 7 MHz ultrasound pulse sequences designed to cause microbubble translation and disruption.

Authors:  Kennita Johnson; Rachel Cianciolo; Ryan C Gessner; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2011-11-21       Impact factor: 2.998

9.  In vivo gas body efficacy for glomerular capillary hemorrhage induced by diagnostic ultrasound in rats.

Authors:  Douglas L Miller; Chunyan Dou; Roger C Wiggins
Journal:  IEEE Trans Biomed Eng       Date:  2009-08-25       Impact factor: 4.538

10.  Frequency Dependence of Petechial Hemorrhage and Cardiomyocyte Injury Induced during Myocardial Contrast Echocardiography.

Authors:  Douglas L Miller; Xiaofang Lu; Mario Fabiilli; Kristina Fields; Chunyan Dou
Journal:  Ultrasound Med Biol       Date:  2016-04-26       Impact factor: 2.998