Comparison of nonuniform rotational distortion between mechanical IVUS and OCT using a phantom model.

Yoshiaki Kawase1, Yoriyasu Suzuki, Fumiaki Ikeno, Ryuichi Yoneyama, Kozo Hoshino, Hung Q Ly, George T Lau, Motoya Hayase, Alan C Yeung, Roger J Hajjar, Ik-Kyung Jang.   

Abstract

Optical coherence tomography (OCT) is an optical analog of mechanical intravascular ultrasound (M-IVUS) with much higher spatial resolution. However, no data exist regarding the nonuniform rotational distortion (NURD) with OCT. The aim of the study was to investigate whether OCT generates less NURD relative to M-IVUS. A coronary artery phantom model was constructed with a rubber ring (3.68 mm in diameter), located at the distal end of the phantom. This model was also composed of eight equally spaced steel wires and an additional marker-wire. Two types of vascular phantoms were used, mild curve (90 degrees ) and acute curve (near 180 degrees ). Subsequent M-IVUS (n = 6) and OCT (n = 6) imaging was performed. Eight angles between eight wires, except the marker-wire, were measured from each image. These angles, measured with M-IVUS and OCT, were compared with those of high-resolution optical photography as a gold standard. The average in angle differences was significantly smaller in OCT compared with M-IVUS in the mild curve model (3.2 +/- 1.0 degrees vs, 6.9 +/- 2.1 degrees , p < 0.01). Compared with the latter model, the average in angle differences was exaggerated in the acute curve model with M-IVUS (9.1 +/- 0.9 degrees vs. 6.9 +/- 2.1 degrees , p < 0.05) but not with OCT (3.5 +/- 0.8 degrees vs. 3.2 +/- 1.0 degrees , p= not significant). OCT generates significantly less NURD compared with M-IVUS, especially in tortuous situation.

Mesh:

Year:  2007        PMID: 17189048     DOI: 10.1016/j.ultrasmedbio.2006.07.020

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  15 in total

1.  Correction of rotational distortion for catheter-based en face OCT and OCT angiography.

Authors:  Osman O Ahsen; Hsiang-Chieh Lee; Michael G Giacomelli; Zhao Wang; Kaicheng Liang; Tsung-Han Tsai; Benjamin Potsaid; Hiroshi Mashimo; James G Fujimoto
Journal:  Opt Lett       Date:  2014-10-15       Impact factor: 3.776

2.  Heartbeat OCT: in vivo intravascular megahertz-optical coherence tomography.

Authors:  Tianshi Wang; Tom Pfeiffer; Evelyn Regar; Wolfgang Wieser; Heleen van Beusekom; Charles T Lancee; Geert Springeling; Ilona Krabbendam; Antonius F W van der Steen; Robert Huber; Gijs van Soest
Journal:  Biomed Opt Express       Date:  2015-11-23       Impact factor: 3.732

3.  Rotational distortion correction in endoscopic optical coherence tomography based on speckle decorrelation.

Authors:  Néstor Uribe-Patarroyo; Brett E Bouma
Journal:  Opt Lett       Date:  2015-12-01       Impact factor: 3.776

4.  Localized compliance measurement of the airway wall using anatomic optical coherence elastography.

Authors:  Ruofei Bu; Santosh Balakrishnan; Hillel Price; Carlton Zdanski; Sorin Mitran; Amy L Oldenburg
Journal:  Opt Express       Date:  2019-06-10       Impact factor: 3.894

5.  Airway compliance measured by anatomic optical coherence tomography.

Authors:  Ruofei Bu; Santosh Balakrishnan; Nicusor Iftimia; Hillel Price; Carlton Zdanski; Amy L Oldenburg
Journal:  Biomed Opt Express       Date:  2017-03-15       Impact factor: 3.732

6.  Steerable OCT catheter for real-time assistance during teleoperated endoscopic treatment of colorectal cancer.

Authors:  Oscar Caravaca Mora; Philippe Zanne; Lucile Zorn; Florent Nageotte; Natalia Zulina; Sara Gravelyn; Paul Montgomery; Michel de Mathelin; Bernard Dallemagne; Michalina J Gora
Journal:  Biomed Opt Express       Date:  2020-02-03       Impact factor: 3.732

7.  Automatic correction of the initial rotation angle error improves 3D reconstruction in endoscopic airway optical coherence tomography.

Authors:  Li Qi; Zhijian Zhuang; Shuangyang Zhang; Shixian Huang; Qianjin Feng; Wufan Chen
Journal:  Biomed Opt Express       Date:  2021-11-17       Impact factor: 3.732

8.  Tethered confocal endomicroscopy capsule for diagnosis and monitoring of eosinophilic esophagitis.

Authors:  Nima Tabatabaei; Dongkyun Kang; Tao Wu; Minkyu Kim; Robert W Carruth; John Leung; Jenny S Sauk; Wayne Shreffler; Qian Yuan; Aubrey Katz; Norman S Nishioka; Guillermo J Tearney
Journal:  Biomed Opt Express       Date:  2013-12-13       Impact factor: 3.732

9.  Imaging in-stent restenosis: an inexpensive, reliable, and rapid preclinical model.

Authors:  Tobias Deuse; Fumiaki Ikeno; Robert C Robbins; Sonja Schrepfer
Journal:  J Vis Exp       Date:  2009-09-14       Impact factor: 1.355

Review 10.  Applications of optical coherence tomography in cardiovascular medicine, Part 2.

Authors:  Joseph W Villard; Amit S Paranjape; Danielle A Victor; Marc D Feldman
Journal:  J Nucl Cardiol       Date:  2009-05-29       Impact factor: 5.952