Literature DB >> 17187289

Use of gadolinium chelate to confirm epidural needle placement in patients with an iodinated contrast reaction.

Sanjay K Shetty1, Erik N Nelson, Tara M Lawrimore, William E Palmer.   

Abstract

OBJECTIVE: When performing epidural steroid injections for the management of chronic back pain, imaging guidance and a limited epidurogram improve accuracy of needle placement and ensure appropriate delivery of the injectate into the epidural space. We describe our experience using a gadolinium chelate as an alternative contrast agent for limited epidurography in patients with a history of an iodinated contrast reaction.
DESIGN: Thirty-eight of 2,067 (1.8%) epidural steroid injections performed in our department over a 25-month period (December 2003-January 2006) employed gadolinium. All injections were performed in the lumbar spine employing a paramedian interlaminar approach. Procedural notes and patient charts were reviewed to evaluate for immediate or delayed complications related to incorrect intrathecal or intravascular needle placement. A retrospective analysis of selected fluoroscopic spot images was performed to evaluate confidence of epidural needle placement; this analysis compared these spot images against those obtained from age- and gender-matched control patients in whom iodinated contrast was used to confirm needle placement.
RESULTS: Real-time fluoroscopic guidance permitted confident visualization of an epidurogram at the time of procedure in all 38 cases as documented in the procedural report, and no procedure resulted in a complication due to incorrect needle placement. Retrospective review of fluoroscopic spot images revealed at least moderate confidence of epidural needle placement by both readers in 29/38 cases (76.3%). Fluoroscopic spot images obtained using gadolinium yielded significantly less confidence than images obtained in control patients whose procedures were performed using iodinated contrast (P < 0.01). However, operators were sufficiently confident in needle placement based on real-time fluoroscopic images (not available in our subsequent review) to inject anesthestic in all 38 cases, despite the immediate consequences that could result from intrathecal administration. During the same time period, there were 11/2,067 (0.5%) instances of intrathecal needle placement discovered during attempted epidurography despite the use of fluoroscopy for needle guidance and reliance on loss-of-resistance technique.
CONCLUSION: Gadolinium chelate represents a safe and useful alternative contrast agent for confirmation of epidural needle placement in patients with an iodinated contrast allergy.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17187289     DOI: 10.1007/s00256-006-0228-8

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  24 in total

1.  Efficacy of epidural steroid injections for low-back pain and sciatica: a systematic review of randomized clinical trials.

Authors:  B W Koes; R J Scholten; J M Mens; L M Bouter
Journal:  Pain       Date:  1995-12       Impact factor: 6.961

2.  Intrathecal gadolinium (gadopentetate dimeglumine) enhanced magnetic resonance myelography and cisternography: results of a multicenter study.

Authors:  E Turgut Tali; Nil Ercan; Gaida Krumina; Mohammed Rudwan; Angel Mironov; Qing Yu Zeng; J Randy Jinkins
Journal:  Invest Radiol       Date:  2002-03       Impact factor: 6.016

3.  The effect of repeated epidural sympathetic nerve block on "failed back surgery syndrome" associated chronic low back pain.

Authors:  B Fredman; E Zohar; M Ben Nun; R Iraqi; R Jedeikin; R Gepstein
Journal:  J Clin Anesth       Date:  1999-02       Impact factor: 9.452

4.  Epidural steroid injection: a procedure ideally performed with fluoroscopic control.

Authors:  G Y el-Khoury; S Ehara; J N Weinstein; W J Montgomery; M H Kathol
Journal:  Radiology       Date:  1988-08       Impact factor: 11.105

5.  Cannulation of the epidural space. A comparison of 18- and 16-gauge needles.

Authors:  M J McNeill; J Thorburn
Journal:  Anaesthesia       Date:  1988-02       Impact factor: 6.955

Review 6.  Are gadolinium-based contrast media really safer than iodinated media for digital subtraction angiography in patients with azotemia?

Authors:  Ulf Nyman; Barbara Elmståhl; Peter Leander; Mats Nilsson; Klaes Golman; Torsten Almén
Journal:  Radiology       Date:  2002-05       Impact factor: 11.105

Review 7.  Do minimally invasive procedures have a place in the treatment of chronic low back pain?

Authors:  Alex Cahana; Philippe Mavrocordatos; Jos W M Geurts; Gerbrand J Groen
Journal:  Expert Rev Neurother       Date:  2004-05       Impact factor: 4.618

8.  Visualization of spinal injection procedures using gadolinium contrast.

Authors:  Frank J E Falco; Mariam Rubbani
Journal:  Spine (Phila Pa 1976)       Date:  2003-12-01       Impact factor: 3.468

9.  Gadolinium-enhanced CT angiography of the circle of Willis and neck.

Authors:  John W Henson; Raul G Nogueira; Diego J Covarrubias; R Gilberto Gonzalez; Michael H Lev
Journal:  AJNR Am J Neuroradiol       Date:  2004 Jun-Jul       Impact factor: 3.825

10.  The use of epidural steroids in the treatment of lumbar radicular pain. A prospective, randomized, double-blind study.

Authors:  J M Cuckler; P A Bernini; S W Wiesel; R E Booth; R H Rothman; G T Pickens
Journal:  J Bone Joint Surg Am       Date:  1985-01       Impact factor: 5.284

View more
  5 in total

1.  High-resolution magnetic resonance-guided posterior femoral cutaneous nerve blocks.

Authors:  Jan Fritz; Cary Bizzell; Sudhir Kathuria; Aaron J Flammang; Eric H Williams; Allan J Belzberg; John A Carrino; Avneesh Chhabra
Journal:  Skeletal Radiol       Date:  2012-12-20       Impact factor: 2.199

2.  Augmented reality visualisation using an image overlay system for MR-guided interventions: technical performance of spine injection procedures in human cadavers at 1.5 Tesla.

Authors:  Jan Fritz; Paweena U-Thainual; Tamas Ungi; Aaron J Flammang; Gabor Fichtinger; Iulian I Iordachita; John A Carrino
Journal:  Eur Radiol       Date:  2012-07-15       Impact factor: 5.315

3.  MR epidurography: distribution of injectate at caudal epidural injection.

Authors:  Darra T Murphy; Eoin C Kavanagh; Ashley Poynton; Vikki O Chan; Michael R Moynagh; Stephen Eustace
Journal:  Skeletal Radiol       Date:  2014-08-02       Impact factor: 2.199

4.  An Operator's Experience of the Loss-of-Resistance Technique in Epidural Injections: An Observational Study.

Authors:  Tulin Arici
Journal:  Eurasian J Med       Date:  2021-02

5.  Dural Puncture During Spinal Cord Stimulator Lead Insertion: Analysis of Practice Patterns.

Authors:  Warren A Southerland; Jamal Hasoon; Ivan Urits; Omar Viswanath; Thomas T Simopoulos; Farnad Imani; Hakimeh Karimi-Aliabadi; Musa M Aner; Lynn Kohan; Jatinder Gill
Journal:  Anesth Pain Med       Date:  2022-05-11
  5 in total