Literature DB >> 17181613

Dynamic contour tonometry: principle and use.

Omar S Punjabi1, Christoph Kniestedt, Robert L Stamper, Shan C Lin.   

Abstract

Interindividual variability of central corneal thickness has been found to be a source of error for conventional Goldmann applanation tonometry. The dynamic contour tonometer represents a potentially new technology for non-invasive and direct intraocular pressure (IOP) measurement, and has been proposed to accurately measure the true IOP irrespective of the corneal thickness. It is based on the principle that when the tip of the device exactly matches the contour of the cornea, the pressure measured by a transducer placed on its tip is an accurate indicator of the true IOP. This device is also capable of measuring the ocular pulse amplitude, a variable that has controversial significance in the diagnosis and management of glaucoma. Even though this technique seems to be very promising, further studies are required to conclusively determine the effectiveness of the dynamic contour tonometer in patients having an abnormal or irregular corneal contour.

Entities:  

Mesh:

Year:  2006        PMID: 17181613     DOI: 10.1111/j.1442-9071.2006.01389.x

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  15 in total

1.  Comparison of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in normal and glaucomatous eyes.

Authors:  Fatih Özcura; Nilgün Yildirim; Afsun Şahin; Ertuğrul Çolak
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

2.  Intraocular pressure after Descemet's stripping and non-Descemet's stripping automated endothelial keratoplasty.

Authors:  Yoshiro Mawatari; Akira Kobayashi; Hideaki Yokogawa; Kazuhisa Sugiyama
Journal:  Jpn J Ophthalmol       Date:  2011-03-13       Impact factor: 2.447

3.  Ocular pulse amplitude as a diagnostic adjunct in giant cell arteritis.

Authors:  P B Knecht; L M Bachmann; M A Thiel; K Landau; C Kaufmann
Journal:  Eye (Lond)       Date:  2015-06-19       Impact factor: 3.775

4.  Clinical evaluation of multiparameter correction equations for Goldmann applanation tonometry.

Authors:  P G Davey; A Elsheikh; D F Garway-Heath
Journal:  Eye (Lond)       Date:  2013-03-15       Impact factor: 3.775

5.  Ocular pulse amplitude and retinal vessel caliber changes after intravitreal ranibizumab.

Authors:  Gökhan Pekel; Semra Acer; Ebru Nevin Çetin; Ramazan Yağcı; Alper Kaşıkçı; Ali Çevik
Journal:  Int Ophthalmol       Date:  2014-09-04       Impact factor: 2.031

Review 6.  Tonometers-which one should I use?

Authors:  Kanza Aziz; David S Friedman
Journal:  Eye (Lond)       Date:  2018-02-19       Impact factor: 3.775

7.  Decreased Ocular Pulse Amplitude and Retinal Nerve Fibre Layer in Multiple Sclerosis.

Authors:  Ebru N Cetin; Cagdas Erdogan; Semra Acer; Gülden Sarac; Cem Yıldırım; Levent S Bir
Journal:  Neuroophthalmology       Date:  2013-05-31

8.  Differences between Goldmann Applanation Tonometry and Dynamic Contour Tonometry following Trabeculectomy.

Authors:  Efstathios T Detorakis; Emilia Grammenandi; Ioannis G Pallikaris; Miltiadis K Tsilimbaris
Journal:  J Ophthalmol       Date:  2010-07-13       Impact factor: 1.909

9.  Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry.

Authors:  Anne Herr; Andreas Remky; Thalia Hirsch; Corinna Rennings; Niklas Plange
Journal:  Clin Ophthalmol       Date:  2013-05-03

10.  Does fundus fluorescein angiography procedure affect ocular pulse amplitude?

Authors:  Gökhan Pekel; Semra Acer; Ramazan Yagci; Ebru Nevin Cetin; Mehmet Can Hiraali; Hüseyin Kaya
Journal:  J Ophthalmol       Date:  2013-07-30       Impact factor: 1.909

View more