Literature DB >> 17179367

Reproducibility of postprocessing of quantitative CT perfusion maps.

Pina C Sanelli1, Gregory Nicola, Apostolos J Tsiouris, Igor Ougorets, Charles Knight, Bruce Frommer, Steve Veronelli, Robert D Zimmerman.   

Abstract

OBJECTIVE: The purpose of this study was to assess interobserver and intraobserver variability in evaluation of the reproducibility of quantitative data obtained in semiautomated postprocessing of CT perfusion data sets by observers of different levels of skill and experience and in fully automated postprocessing.
MATERIALS AND METHODS: Twenty CT perfusion data sets were postprocessed by a neuroradiologist using an automated postprocessing program and by five observers (neuroradiology attending, neurology attending, radiology resident, senior and junior CT technologists) who received a brief training session in use of software for semiautomated postprocessing. For assessment of intraobserver variability, each observer repeated postprocessing of 10 CT perfusion data sets. Standard regions of interest were placed on identical locations for each observer's cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) maps of three brain regions: an ischemia-infarct region, normal cortical gray matter, and white matter.
RESULTS: The variability in mean quantitative values of CBF, CBV, and MTT was 2.5-9.5% among all observers. Greater variability (20.4%) was introduced with the automated program. High correlation was found among all possible pairings of observers (r = 0.87-0.99). Low correlation was observed between automated postprocessing and postprocessing by all observers. Intraobserver variability in quantitative CT perfusion data ranged from 0.29% to 10.8%. High intraobserver correlation (r = 0.91-0.99) was found for the observers.
CONCLUSION: Quantitative CBF, CBV, and MTT data obtained from postprocessing of CT perfusion data sets are reproducible among observers with varying levels of skill and experience. Observer interaction with the software is an important component for correct identification of user-defined parameters. Establishing a uniform and standard postprocessing technique is essential for maintaining good reproducibility.

Entities:  

Mesh:

Year:  2007        PMID: 17179367     DOI: 10.2214/ajr.05.2188

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  14 in total

1.  Standardization of Stroke Perfusion CT for Reperfusion Therapy.

Authors:  Guangming Zhu; Patrik Michel; Weiwei Zhang; Max Wintermark
Journal:  Transl Stroke Res       Date:  2012-03-28       Impact factor: 6.829

2.  CT coronary angiography: quantitative assessment of myocardial perfusion using test bolus data-initial experience.

Authors:  Ashley M Groves; Vicky Goh; Sabarinath Rajasekharan; Irfan Kayani; Raymondo Endozo; John C Dickson; Leon J Menezes; Manu Shastry; Said B Habib; Peter J Ell; Brian F Hutton
Journal:  Eur Radiol       Date:  2008-05-09       Impact factor: 5.315

3.  Effect of training and experience on qualitative and quantitative CT perfusion data.

Authors:  P C Sanelli; G Nicola; R Johnson; A J Tsiouris; I Ougorets; C Knight; B Frommer; S Veronelli; R D Zimmerman
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

4.  Using CT perfusion during the early baseline period in aneurysmal subarachnoid hemorrhage to assess for development of vasospasm.

Authors:  Pina C Sanelli; Austin Jou; Rachel Gold; Melissa Reichman; Edward Greenberg; Majnu John; Zuzan Cayci; Igor Ugorec; Axel Rosengart
Journal:  Neuroradiology       Date:  2010-08-07       Impact factor: 2.804

5.  Vasomodulation of tumor blood flow: effect on perfusion and thermal ablation size.

Authors:  Hanping Wu; Agata A Exner; Tianyi M Krupka; Brent D Weinberg; John R Haaga
Journal:  Ann Biomed Eng       Date:  2008-12-16       Impact factor: 3.934

6.  Functional CT of squamous cell carcinoma in the head and neck: repeatability of tumor and muscle quantitative measurements, inter- and intra-observer agreement.

Authors:  Sotirios Bisdas; Katarina Surlan-Popovic; Vojko Didanovic; Thomas J Vogl
Journal:  Eur Radiol       Date:  2008-04-30       Impact factor: 5.315

Review 7.  Intracarotid delivery of drugs: the potential and the pitfalls.

Authors:  Shailendra Joshi; Phillip M Meyers; Eugene Ornstein
Journal:  Anesthesiology       Date:  2008-09       Impact factor: 7.892

Review 8.  Improving Reperfusion Therapies in the Era of Mechanical Thrombectomy.

Authors:  Italo Linfante; Marilyn J Cipolla
Journal:  Transl Stroke Res       Date:  2016-05-24       Impact factor: 6.829

9.  Automated versus manual post-processing of perfusion-CT data in patients with acute cerebral ischemia: influence on interobserver variability.

Authors:  Bruno P Soares; Jan Willem Dankbaar; Joerg Bredno; SuChun Cheng; Sumail Bhogal; William P Dillon; Max Wintermark
Journal:  Neuroradiology       Date:  2009-03-10       Impact factor: 2.804

10.  Quantitative analysis of CT-perfusion parameters in the evaluation of brain gliomas and metastases.

Authors:  Anna Maria Di Nallo; Antonello Vidiri; Simona Marzi; Alessandra Mirri; Alessandra Fabi; Carmine Maria Carapella; Andrea Pace; Marcello Crecco
Journal:  J Exp Clin Cancer Res       Date:  2009-03-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.