OBJECTIVE: The purpose of this study was to determine the feasibility of imaging the colon with fused CT colonography (CTC) and 18F-FDG PET and to correlate the findings with the histologic features of polyps. SUBJECTS AND METHODS: Eighteen patients with suspected colorectal polyps enrolled in this prospective study. Before colonoscopy, 17 of the patients underwent a combination of FDG PET and CTC. CTC consisted of 4-MDCT merged with PET. PET of the abdomen and pelvis was performed after each CTC scan. One radiologist and one nuclear medicine physician in consensus analyzed PET and CTC fusion data. PET standard uptake value was correlated with the findings at histologic examination of polyps. Patient feasibility was defined as the ability to tolerate prolonged scanning with good colonic distention. Technical feasibility was determined by how closely anatomically matched polyps overlapped on fusion images.
RESULTS: Seventeen of 18 patients tolerated scanning. Eighty-five percent of colon segments were optimally distended. Twenty-three of 27 FDG-avid polyps measuring 10 mm or more had excellent overlap at fusion imaging. PET depicted 23 of 39 premalignant polyps and even showed increased tracer activity associated with four small tubular adenomas (4-6 mm). Sixteen benign polyps (10-25 mm) were not depicted on PET. All nine cases of cancer (tumors measuring 11-60 mm) were detected with both PET and CTC. The standard uptake value of malignant tumors ranged from 4 to 20 (mean, 9). However, six benign flat polyps did not exhibit FDG avidity.
CONCLUSION: The novel combination of CTC and PET was feasible in 17 of 18 patients and allowed excellent image correlation in 23 of 27 proven polyps measuring 10 mm or more on PET-CTC fusion. This technique shows promise in accurate anatomic correlation of both malignant and premalignant lesions evaluated with FDG PET.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17179355     DOI: 10.2214/AJR.05.1458

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  8 in total

Review 1.  Positron emission tomography for benign and malignant disease.

Authors:  Anthony Visioni; Julian Kim
Journal:  Surg Clin North Am       Date:  2011-02       Impact factor: 2.741

2.  PET/CT colonography in patients with colorectal polyps: a feasibility study.

Authors:  Pier Paolo Mainenti; Barbara Salvatore; Dario D'Antonio; Teresa De Falco; Giovanni Domenico De Palma; Francesco Paolo D'Armiento; Luigi Bucci; Leonardo Pace; Marco Salvatore
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-05-11       Impact factor: 9.236

3.  A polyp from another polyp.

Authors:  Vincent Kuo; Wareef Kabbani; Jeffrey Linder
Journal:  Can J Gastroenterol       Date:  2013-12       Impact factor: 3.522

Review 4.  Virtual gastrointestinal colonoscopy in combination with large bowel endoscopy: clinical application.

Authors:  Qing He; Ting Rao; Yong-Song Guan
Journal:  World J Gastroenterol       Date:  2014-10-14       Impact factor: 5.742

5.  PET/CT colonography: a novel non-invasive technique for assessment of extent and activity of ulcerative colitis.

Authors:  Chandan J Das; Govind K Makharia; Rakesh Kumar; Rajender Kumar; Rajeew P Tiwari; Raju Sharma; Arun Malhotra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12-22       Impact factor: 9.236

Review 6.  PET-CT in oncology: making the most of CT.

Authors:  K A Miles
Journal:  Cancer Imaging       Date:  2008-10-04       Impact factor: 3.909

Review 7.  PET/CT imaging in the diagnosis, staging, and follow-up of colorectal cancer.

Authors:  Raghu Vikram; Revathy B Iyer
Journal:  Cancer Imaging       Date:  2008-10-04       Impact factor: 3.909

8.  Focal colorectal uptake in (18)FDG-PET/CT: maximum standard uptake value as a trigger in a semi-automated screening setting.

Authors:  Wolfgang Luboldt; Baerbel Wiedemann; Sebastian Fischer; Boris Bodelle; Hans Joachim Luboldt; Frank Grünwald; Thomas J Vogl
Journal:  Eur J Med Res       Date:  2016-01-09       Impact factor: 2.175

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.